Please click here to check who's online and chat with them.

Nancy

Supplier From China
Apr-08-21
Supplier : Power products like voltage transformers, current transformers and fuses

Established: 2020

Verification Status



Contact Details:
Huojia County, Xinxiang City, Henan Province, China
Xinxinag 453800
China


Recent User Reviews

This user has not received any reviews yet!
 
 
Contact Supplier
Renew

More Items Similiar to: Nancy

GOLD Member
Mar-01-24

Transformers

$20
MOQ: Not Specified
Supplier From Ludhiana, Punjab, India
 
Transformers,Distribution and Power Transformer,Varivolt
Safety Transformers
Diesel Generators
Industrial Panels
Stabilizers
Energy Saver
Industrial Panels
VERIFIED
Sep-10-22
Supplier From Visakhapatnam, Andhra Pradesh, India
 
Description
Multi Tap Transformers allow greater flexibility in managing multiple wire runs by moving cables up and down the multi range. Our Resin Sealed Transformers ensure highest possible efficiency & reliability.

Features
Low Voltage Transformer ranging from 75 W - 1200W 120, 277 /12, 13, 14, 15V with Toroidal /EI.
50/60 Hz
Protection for each output circuit.
Photo cell Option
Rainproof Enclosure
Stainless Steel / Powder Coated.
VERIFIED
Sep-10-22
 
Product Details :

The Transformer used in the power supply unit is manufactured as per the UL norms.
The transformer will be potted/sealed in an enclosure using Epoxy (a mixture of Resin Hardener) which ensures high reliability and efficiency.

The enclosure is made up of Prime Stainless Steel material SS 304 grade (also carbon steel with powder coated enclosure can be provided on request )

Block Terminals will provide the easiest way for the customer to connect the secondary tappings. Photocell and timer connected as per the customer's needs.

A circuit breaker of 25A is provided for circuit protection.
Technical Details
Wattage - 300w
Frequency - 50/60 Hz
Pry. voltage - 120V /277V
Sec... voltages As per customer requirements
Insulation class F, H
Max. regulation 10%
Dielectric 2000v, primary to secondary for 1 second.
Dielectric 2000v, all windings to lamination for 1 second.
Aug-09-19
 
Rated frequency
50Hz or 60Hz
Rated secondary current
5A or 1A
Rated short-time thermal current
40kA,1s
Rated insulation level
12/42/75 kV
Ambient temperature
25~40
Altitude
Up to 1000m above sea level

Indoor device
Standards
The product performance is in accordance with GB20840.1 GB20840.2 and IEC61869-1 IEC61869-2 standards.
Sep-01-22
 
Product description

Transformer Standard current transformer are also called precision current transformers, current transformer standards, standard CT and current transformer standards. Transformer standards are divided into current transformer standards and voltage transformer standards. Standard current transformers are used in the error test of transformers. Used as a current transformer calibration standard



technical parameter

1. Temperature:

2. Relative humidity

3. Rated Primary Current:5-5000A 5A,1A

4.Rated secondary current:5 1A

5 Accuracy Class 0.05S

6. Allow long-term work under the rated current; More than120A across the core.



Precautions:

1. The current of standard CT and tested CT must be the same in CT calibration.

2. Follow the given wiring diagram strictly.

3. Test whether the load box is accurate or not before calibrating the transformer.

4. Forbid secondary winding opening during the calibration.

5. Select demagnetization before calibration.The wiring diagram is shown in figure 5.

Short out the secondary winding before cutting off the power when the demagnetization is finished.

6.Principle wiring diagram of CT with large current generator is similar to above diagram. They are the same except the output winding of large current generator and primary winding of transformer are the same one.
Dec-03-21

Current Transformer

$770 - $15.40K
MOQ: Not Specified
 
Product description

Transformer Standard current transformer are also called precision current transformers, current transformer standards, standard CT and current transformer standards. Transformer standards are divided into current transformer standards and voltage transformer standards. Standard current transformers are used in the error test of transformers. Used as a current transformer calibration standard



technical parameter

Temperature -5 40

Relative humidity 80%

Rated Primary Current 5-5000A 5A,1A

Rated secondary current 5A 1A

Accuracy Class 0.05S
Allow long-term work under the rated current; More than120A across the core.



Precautions

The current of standard CT and tested CT must be the same in CT calibration.

Follow the given wiring diagram strictly.

Test whether the load box is accurate or not before calibrating the transformer.

Forbid secondary winding opening during the calibration.

Select demagnetization before calibration.The wiring diagram is shown in figure 5.

Short out the secondary winding before cutting off the power when the demagnetization is finished.

Principle wiring diagram of CT with large current generator is similar to above diagram. They are the same except the output winding of large current generator and primary winding of transformer are the same one.
GOLD Member
Feb-07-00
Supplier From Mumbai, Maharashtra, India
Sep-10-13
 
Current transformer.
Jun-02-14
Supplier From Ghaziabad, Uttar Pradesh, India
 
We are one of the leading manufacturer of all types cts of any ratio. We manufacture both outdoor and indoor types. We manufacture both resin cast & oil cooled cts

As per mutual discussion

Verification Status