Supplier: New type of embolism conveyor system, ash transfer system of cyclone dust collector of gas making furnace, conventional pneumatic conveying systems, valves, pipes, tubes
Main features:
1)Can control the two heating zones individually with two instrument
2)Chamber veined with 12 sets of resistance wire, achieve uniform tem. field and longer constance zone.
3 Equipped with support frame for flange, reduce the load of tube body
4 Pneumatic spring for opening, which is safer for the operator.
5 Open type makes convenient for operation
Technical Parameters
Power
Power rated: 5KW (208-240V)
Voltage
Voltage rated: AC208-240V 50/60HZ
Working Temperature Max. Temperature: 1200 °C
Continuous working temperature: 1100
Heating Rate: °C /min
Temperature Controller
PID automatic control and auto-tune function.
30 programmable segments for precise thermal processing.
Built-in protection for the over-heated and broken thermocouple.Â
Length of heating zone
200+200mm
Length of constant zone
100+100mm
Heating Elements
Resistance wire, Fe-Cr-Al Alloy doped by Mo
Temperature Accuracy
+/- 1 °C
Processing tube
High quartz tube:25/50/60/80/100*1000mm(optional)
Tube blocks are included for blocking heat radiation generated from tube center. Must be fully inserted into the furnace chamber before heating at the correct position. ceramic or quartz blocks are optional
Net Weight 40kg
Dimensions
590*380*500mm(L*W*H without tube & flange)
Vacuum Flange KF25 quick clamp flange
Vacuum Pressure
10-1pa can be achieved by a mechanical pump
10-3 pa can be reached by molecular pump
ï??Used in Lab as material sintering furnace, annealing furnace, smelting furnace, dental furnace, etc.
ï??It is possible to add a vent to be used as Nitrogen protection furnace, Argon protection furnace, Oxidizing furnace, Carbonizing furnace.
ï??A general necessary electric furnace for experiment in Lab.
Technical Parameters
Power
ï?·Power rated: 4KW (220V)
Voltage
ï?·Voltage rated: AC 220V 50/60HZ
Furnace structure
ï?·High purity fibrous alumina insulation for maximum energy saving - 30% less power consumption than other brands
ï?·Double air cooling structure to control furnace surface Temp. no more than 60 when furnace is heated into max. Temp.
ï?·The spring door buckle is used to solve the contraction gap caused by high temperature in the chamber of the equipment.
ï?·Equipped with inspection window on the front,convenient to to observe the situation inside the chamber
Working Temperature
ï?·Max. Temperature: 1200 °C
ï?·Continuous working temperature: â?¤1100
ï?·Recommended Heating Rate: 5-20°C /min
Max. heating rate
ï?·30/min
Temperature Controller
ï?·PID automatic control and auto-tune function.
ï?·30 programmable segments for precise thermal processing.
ï?·Built-in protection for the over-heated and broken thermocouple.
Thermocouple
ï?·K type
Heating Elements
ï?·Fe-Cr-Al Alloy doped by Mo
Temperature Accuracy
+/- 1 °C
Dimensions
ï?·Chamber size(L*D*H): 250*300*250mm (18L)
Warning
ï?·The equipment is not sealed, and can not be put into toxic, harmful, inflammable and explosive gas. Can add the inlet port to pass through the inert gas or oxygen.