Silicon fire barrier
sealant Density(g/cm3):About 1.15~1.25
Color:Light Gray
Hardness (full cured):Shore A 30~40
Elongation at break:f+200%
Flexibility:+200%~-40%
Tack-free time:About 30min.
Comply with UL1479 and UL2079
300ml/cartridege; 25cartridge/carton
Carton Size:25cm*25cm*25cm
Gross Weight per carton:9KGS
Product Specification
Fire Extinguishing Ball is a ball shaped fire extinguisher. Simply thrown into a fire, it will activate within 3-5 seconds and effectively disperse fire -extinguishing chemicals. When a fire occurs and no one is present, Fire Extunguishing Ball will self-activate when it comes into contact with fire and give a loud noise as a fire alarm. Because of this feature, it can be placed in any fire prone are such as above electrical circuit breaker or in a kitchen. There is no special training or skill required to operate the ball and no need to face the dangers of the fire. No inspection and maintenance aare required for the product life span of upto five years.
Shape of the Device : Spherical Shape
Weight of the Ball : 1.3 Kg
Covering an Area : upto 4 squqre meter upon activation
Main Chemical used : Mono Ammonium Phosphate
Out side film : PVC / PVE
Foam : Penfoam - recyciable - contain no CFC and HCFCS, Environment Friendly
Fire + Breaker : In rubber tube of Fire Extinguisher Ball
Activation Time : 3-5 Seconds of exposure from flames
Extinguish Class : A, B and C Fires
Manufacturers and distribution of all types of fire fighting equipment such as hydrants, couplings, nozzles, hoses, extinguishers, sprinklers etc.for water and foam-based systems.
Versatile: blotfire stored pressure type fire extinguishers are extremely versatile, they will tackle the majority of fire risks found in most commercial, industrial and domestic environments.
Class a- fires involving combustible solids like wood, paper, cloth etc.
Class b- fires involving inflammable liquids like oil, kerosene, petrol etc.
Class c- fire involving inflammable gases like cng, lpg etc and electrically started fires.
Maintenance free : does not require periodic maintenance & servicing as it has a pressure gauge that at a glance gives the condition of the extinguisher whether it is in working condition.
5 years warranty:
Blotfire has an active shelf for 5 years. Thus it is a sound investment in fire safety.
Better performance:
A) lesser time period to discharge 95 % of contents.
B) greater area coverage. More powder particles attack the fire radicals at one given time resulting in faster knock down, and the bigger particle size covering larger area.
Light weight:
Superior technology has enabled lighter tensile strength to be used. Thus helping anyone in crisis to carry the fire extinguisher to the scene of fire without any loss of precious time, making mobility easier.
Ease of use:
The simple squeeze grip operation of the extinguisher helps to put the extinguisher into action by a layman without any formal training.
Non-corrosive:
The powder particles are silicon coated thus not absorbing moisture, resulting in non-caking of the powder. Increasing the shelf life of the chemical and the cylinder because body is also not corrosive.
For 1kg 12pcs in a carton
For 2kg 12pcs in a carton
For 5kg 4pcs in a carton
EN 45545-2 New Fire test to railway vehicles - European Standard
EN 45545-2:2013+A1:2015: Fire protection of railway vehicles - Part 2: Requirement for fire behaviors of materials and components
Scope
This part of EN 45545 specifies the reaction to fire performance requirements for materials and products used on railway vehicles as defined in EN 45545-1.
For each hazard level, this part specifies the test methods, test conditions and reaction to fire performance requirements.It is not within the scope of this European Standard to describe measures that ensure the preservation of the vehicles in the event of o fire.
Hazard levels
HL1, HL2, HL3
Test Method
EN 45545-2 R1: Surface Products
EN 45545-2 R10: Flooring Covering
EN 45545-2 R15, R16: Wire & Cable
EN 45545-2 R22/ R23: Interior seals, Electrical Equipment
EN 45545-2 R24 : Electrotechnical products
EN 45545-2 R24/R25 : PCB Printed circuit boards
EN 45545-2 R26 : Small electrotechnical products
Reference Standard
EN 45545-1: Fire Protection of railway Vehicles â?? Part 1: General
EN 45545-2: Requirement for fire behaviour of materials and components
EN 45545-3: Fire resistance requirements for fire barriers and partitions
EN 45545-4: Fire safety requirements for railway rolling stock design
EN 45545-5: Fire safety requirements for electrical equipment
EN 45545-6: Fire control and management system
EN 45545-7: Flammable liquid and flammable gas installations
We also can provide the following service of fire test to Railway
EN45545-2 Fire protection of railway vehicles: Requirement for fire behaviors of materials EN45545-3 Fire resistance requirements for fire barriers
NFPA 130 Standard for fixed guideway transit and passenger rail systems
DIN5510-2 Fire behaviour of materials and parts, classification, requirement
BS6853 Code of practice for fire precautions in the design and construction
NF F16-101 Railway Rolling Stock Fire Behavior Choice of Material
CASfire Technical Co.,Ltd
8F Building 4, Chinese Academy of Science,
No.255 South Duiying Road,Jimei, Xiamen 361021, China
Tel: (+86) 0592-3500085
MP: (+86) 18906059211
Email: info@casfire.cn