The structure of disc suspension insulators enables them form the insulator string by fitting into themselves one another as per voltage requirement.
Connected fitting type: ball & socket type; clevis & tongue type
Strength can be 40 kn, 45kn, 60kn, 70kn, 80kn, 100kn, 110kn, 120 kn, 125kn, 160kn, 210kn, 300kn
Main type:
Standard suspension insulator:
Ansi type: 52-1, 52-2, 52-3, 52-4, 52-5, 52-6, 52-8, 52-9 according to ansi c29.2
Iec type: u70bl, u70bs, u100b, u120b, u160b, u210b, u300b according to iec383, bs137
Fog type anti-pollution suspension insulators
Double shed anti-pollution insulators
Model NO.:52-3
Material:Porcelain
Type:52-3
Connection Method:Trough Type
Certification:CE, ISO9001, SGS
Specification:ANSI
HS Code:8546209090
Application:High-voltage
Structure:Suspension Insulator
Usage:Insulation
Size of Bearing Capacity:89kn
Color:Brown
Wet:4.6kg
Package:Wooden Crate or as Per Customers Requirement
Min. Order:1,000 Pieces
Port:Fuzhou, China
Production Capacity:100000 Pieces/Month
Payment Terms:L/C, T/T
According to customers' request, such as: Technical reference,Fechnical Specification,Drawing paper, Samples etc., Our company can make long-term relationship with cooperative partners, and sales by samples or processing and production by data.
Composite Insulator
Design:
1) GB/T19519-2004; IEC; ANSI
2) KEMA certification, ISO 9001
3) 10~1000kV / 70~600KN
4) Material: composite Polymer
5) Self-refined silicone rubber with imported raw material from DOR CORNING CO. USA; Fumed silica is imported from CABOT CO. in the USA and WACKER CO. in Germany.
6) Weathershed: silicon-rubber sheds are the feature of TAIGUANG technology.
7) Made of ECR core, acid and high temperature resistance.
8) Metal end fittings: advanced compressing technique with Acoustic Emission Detector imported from Finland.
Performance:
1) Excellent electrical insulation properties and restoration of insulator performance
2) High mechanical strength
3) Good features of light weight, self cleaning, easy to install, anti-aging.
4) Good resistance to soiling and flashover
5) Hydrophobicity of sheds meets class HC1
.
- excellent impact resistance
- the characteristics to repel water of polymer material
- excellent mechanical properties
- easier construction thank to the light weight
-easier construction thanks to the light weight
- excellent impact resistance
Excellent mechanical properties
- the characteristics to repel water of polymer material
Model NO.:FXBW-35/70
Material:Composite Polymer
Type:B Type Insulator
Connection Method:Trough Type
Certification:ISO9001, Cnas,Cnal
Chemistry:Organic Insulation
Origin:China
Brand:Zhon
Application:High-voltage
Structure:Suspension Insulator
Usage:High Voltage Power Transmission
Size of Bearing Capacity:70KN
Color:Grey
Maximum Voltage:10kv~500kv
Thermal Rating:200 200
Specification:35KV
HS Code:8546900000
Production Capacity:10, 000PCS/Month
Package:Carton or Plywood Case
Payment Terms:L/C, T/T, Paypal, Western Union
Cat.No. 55-5
Creepage distance mm 305
Dry arcing distance mm 159
Cantilecer strength kn 13
Low frequency dry flashover voltage kv 80
Low frequency wet flashover voltage kv 45
Positive kv 130
Negative kv 150
Maximum riv at 1000khz uv 100
Test voltage to ground kv 15
Power-frequency puncture voltage kv 115
Net weight each approx kg 2.75
Number in standard package 12
Types: Porcelain disc insulator/suspension insulator, pin insulator, line post insulator, station post insulator.
DISC INSULATORS
Porcelain disc insulators are the most widely used in strings, they can be used for any voltage depending on the numberof units mounted in series for transmission and distribution lines.
Voltage & Mechanical Range
11kV-765kV. 40kN-300kN.
Application
The insulators are designed to be suitable for different types of polluted zones and mechanical strength according to client's requrests. Life expectancy of these insulators are extremely high but may be adversely affected if operated beyond specified limits of electrical or mechanical stress.
STATION POST INSULATOR
the most comprehensive range of porcelain post insulators up to highest system voltages with the most progressive technology, engineering and life time. Short production time, tighter tolerances, flexible design, extra-high mechanical strength and extended creepage distances are possible by wet/dry process.
Voltage Range
IEC station post insulators manufacture in full accordance to IEC60273. Operating rod columns for disconnectors are manufactured corresponding to the relevant post insulators. Insulation requirements are available in ratings from BIL 60kV to 2550kV.
TR station post insulators manufacture in full accordance with ANSI C29.9. Insulation requirements are available in ratings from 95 kV to 2050 kV. Special requirements can be also offered upon request.
Standard
post insulators conforms to specifications of IEC 60273 and ANSI-C29.9.
Application
The post insulator up to 500kV can be used for switchgears, disconnectors and substations.