overview
The diaphragm of the differential pressure level transmitter is used to prevent the medium in the pipeline from directly entering the pressure sensor component of the differential pressure transmitter. It uses a filling fluid such as silicone oil to transmit pressure between the transmitters.
The HR3051-LT differential pressure level transmitter be used for measuring the level, density, pressure, and flow of a liquid, gas, or vapor and converts it into a 4-20 ma DC HART current signal output. The RP2001 can also communicate with the RST375 handheld te
rminal or the RSM100 Modem for parameter setting, process monitoring, and more. The measuring range of the HR3051-LT differential pressure level transmitter (when not moved) is 0-1kPa~2MPa, and the rated pressure of the liquid level flange is: 1.6/4MPa, 6.4MPa, 10MPa, 150psi, 300psi or 600psi.
Working principle and structure
The HR3051-LT differential pressure level transmitter consists of a HR3051-DP differential pressure transmitter and a soldered liquid level flange. Its working principle is the same as HR3051-DP type differential pressure transmitter (see HR3051-DP type differential pressure transmitter technical specification), except that the pressure transmission path on the positive pressure side is slightly different: the pressure acting on the high pressure side is firstly The diaphragm and filling liquid on the liquid level flange pass through the transmitter body and finally reach the high voltage side of the measuring sensor.
Comparison of range code and range limits
Range code Minimum range Maximum range Rated pressure (maximum)
B 1kPa 6kPa Rated pressure of the liquid level flange
China factory Transmitter GP2A2B21AB4M5D1 for Rayalaseema power
Deyang YOYIK have power plant professional accessories, non-standard pieces, to spare parts for processing. Only need to figure the number of other companies need drawings and drawings number. If you have any questions or concerns, please contact us. YOYIK has a good talent pool, the company is developing, you need to support, in order to witness its growth.
Yoyik can offer many spare parts for power plants as below:
Long battery life. By stand-by mode, battery lasts 1000h.
Power switch remotely controllable. You can control on/off of rcs-50 by rcs-20t. Controllable range is nearly 100m.
Original code between rcs-50 (transmitter) and rcs-20t (remote controller) avoid interference with the other unit if someone use it in the same area.
<*1>bug detectors can not detect sleeping transmitter.
(RCS-50)
Size... 67 x 21 x 70 (73)mm / antenna °3 x 220mm
Weight... 162g (with alkaline batteries) / antenna 3g
Power supply... "006p" (6f22/6lr61) 9v battery x 1
Battery life... Approx. 62h (6lr61, continuous transmission) / approx. 1000h (stand-by mode, no transmission)
Available channels... Uhf-a, uhf-b
Mic effective range... 15m from circle point.
(RCS-50)
Size... 42.5 x 21 x 112 (120) mm / rod antenna 20mm (shortened) - 460mm (extended)
Weight... 162g (with alkaline batteries) / antenna 3g
Power supply... "006p" (6f22/6lr61) 9v battery x 1
Battery life... Approx. 11h (6lr61, continuous transmission)
Controlling rcs-50... Keep pressing button 5 seconds to turn on rcs-50. Same procedure to turn it off. Rcs-20t uses vhf frequency for remote control.
1. All the supplied products are provided with product certificates and instructions, including product number, technical parameters, wiring diagram,factory date, etc. Please check carefully to avoid misuse.
2. Installation should check whether the field interface is connected to the product according to the connection mode and thread type of the product.The mouth is the same. If it is a threaded interface, it should be tightened slowly and sealed carefully. Torque can not be added directly to the transmitter shell, but only on the six sides of the pressure interface.
3. The wiring should be strictly in accordance with the instructions of our company.
4.This product is a precise instrument. It is forbidden to disassemble, colide,fall,throw hard or punch the drainage hole with a sharp instrument.
5. The transmitter can work by electricity, but the preheating output is stable for 30 seconds.
6. If any abnormality is found in use, the power supply should be turned off, the use should be stopped, the inspection should be carried out, or contact our technical department direct.
7.When transporting and storing, the original packaging should be restored and stored in a cool, dry and ventilated warehouse.
8.The quality assurance period is 12 months.
Intelligent Operation Method
1. LCD shows the output percentage or process pressure. Press the S key to select the display percentage or pressure.Press Z key to select pressure unit KPa or Mpa when displaying pressure.
2. Press S+Z key for 8 seconds, then release it at the same time, press Z key to set the zero value; Press the S key set the range. note: this function can only be triggered once an operation.
3. Adjustments to zeros or ranges may cause changes in the displayed options, i.e.The percentage being displayed becomes pressure or KPa becomes Mpa, etc. All these changes are shown only in the display, and have no effect on the internal parameters of the transmitter, pressure detection and current output. After adjusting the zero point and range, the S and Z keys can be used to select the desired percentage or pressure.
4. Zero-setting in field pressure-free state: 30 seconds after pressing S+Z key, the display shows zero time at the same time release the two keys, that is, zero.
Simulated operation method
1.Zero-setting in pressure-free condition: The potentiometer with the word "zero" on the circuit board is adjusted to zero when it is displayed on the spot.(Note: Clockwise increase, counterclockwise decrease)
2.The potentiometer marked "range" on the circuit board can not be adjusted without standard pressure, so as to avoid the disorder of measurement range.
The series of pressure transducers use imported high-quality pressure sensors and special integrated modules, through fine temperature, zero, full range, and non-linear compensation to achieve accurate measurement and transmission of pressure changes in liquid, gas, steam and other media.
Technical Index
Measuring medium: liquid, gas, steam
Pressure range: -0.1MPA~0~60MPA
Accuracy grade: ±0.2%FS, ±0.5%FS
Stability: â?¤0.2%FS/year
Temperature drift: â?¤0.02%FS/(range 0~70)
Environment temperature: -20+85
Storage temperature: -20+85
Output signal: 4-20mA or 1-5VDC
Supply voltage: 12-40VDC
Allow overload: two times the quota voltage
Explosiveproof grade: intrinsically safeia II C T6 flameproof dII C T6
Wetware material: 316 stainless steel and 1Gr18Ni9Ti
Shell material: die casting alloy aluminum,surface epoxy spraying
Pressure interface: M20X1.5
Weight: ordinary 0.75kg, with on-site instructions 1kg
Structure Type
x1
Connection
x2x31
x4
The link mode and output signal of the compact tranmitter are as follows:
Two-wire system:
1 Positive power supply
2 Negative power supply
3 Empty
4 Shell
Three wire system:
1 positive power supply
2 Negative power supply (Negative sharing with signals)
3 Signal+
4 Shell
x5
The connection mode of aviation plug transmitter is as follows:
Two-wire system(direct outlet type)
1 Red wire connection positive power supply
2 Black wire connection negative power supply
Notice
1. All the supplied products are provided with product certificates and instructions, including product number, technical parameters, wiring diagram,factory date, etc. Please check carefully to avoid misuse.
2. Installation should check whether the field interface is connected to the product according to the connection mode and thread type of the product.The mouth is the same. If it is a threaded interface, it should be tightened slowly and sealed carefully. Torque can not be added directly to the transmitter shell, but only on the six sides of the pressure interface.
3. The wiring should be strictly in accordance with the instructions of our company.
4.This product is a precise instrument. It is forbidden to disassemble, colide,fall,throw hard or punch the drainage hole with a sharp instrument.
5. The transmitter can work by electricity, but the preheating output is stable for 30 seconds.
6. If any abnormality is found in use, the power supply should be turned off, the use should be stopped, the inspection should be carried out, or contact our technical department direct.
7.When transporting and storing, the original packaging should be restored and stored in a cool, dry and ventilated warehouse.
Quick Details
Place of Origin: Sichuan, China (Mainland)
Brand Name: SAND
Model Number: PT124B
Pressure Range: 0~5~150MPa / 0~500~20000psi
Accuracy: ±1.0%FS
Power: 24VDC(9~36VDC)
Output: 0~5V or 1~5V or 0~10V or 0~20mA or 4~20mA
Probe Temperature: 400
Temperature Drift:
Except the level transmitter, A&S Transmitter Co., Ltd. also can provide below products:
pressure transmitter,flow transmitter,temperature transmitter,differential transmitter,level gauge and flow meter.
Except the level transmitter, A&S Transmitter Co., Ltd. also can provide below products:
pressure transmitter,flow transmitter,temperature transmitter,differential transmitter,level gauge and flow meter.