Supplier : Explosion-proof lighting fixtures, explosion-proof appratus for industrial, mining, marine, and offshore usage, portable lighting, waterproof and dust-proof light fitting and appratus, elevators, and floor building material
Established: 1987
Standards: ISO9001
Verification Status
Contact Details:
No. 555 Baoqian Road, Jiading
Shanghai
201808
China
* PURPOSE
customers using FBC boilers (Particularly underbed feed FBC boilers) for the protection of inbed coils against erosion potential by applying highly abrasive resistant refractory on inbed coils above fuel feed system.
BACKGROUND
* Two of such actions are providing special alloy studs on inbed coils and applying highly abrasive resistant refractory on the outer bottom loops of inbed Coils which are above the fuel feed nozzles.
* GANESHAS has taken number of approaches to identify the key factors affecting erosion rates with an objective to enhance the life of inbed tubes as well as implementing the corrective action to reduce the erosion rates.
Phosphate coatings are often used to protect steel parts against rusting and other types of corrosion
* Erosion of inbed coils in fluid bed combustor is unavoidable phenomenon however the rate of metal wastage and thus the life of tubes depends on various factors like ash & fuel properties, design of Combustor / feeding system, flue gas velocities operating conditions etc. It has been also observed that maximum erosion prone inbed coils are those which come above fuel feed nozzles and an area of approximately 1 to 1.5 mts around fuel feed systems are badly affected.
APPLICATION
Phoscast-90 XR can be applied by ramming with wooden mallet having adequately large head @" dia x 5" length x 10â?? Jong handle). The desired lining or repair thickness is built up in several courses while ramming the mass to uniform thickness. Phoscast refractory should never be trawled to obtain smooth surface; ramming only should finish surface. Any excess mass is to be sliced off with trowel edge and then finished by ramming again for bed coil. Tube application of AFBC boiler, the material pasty mass should be finger pressed into the studs of the tube with maximum force. Finish should be given by pressing the hand palm against material applied, using surgical type thin rubber hand gloves.
As an industry leader in explosion-proof elevators, Safi Group srl Elevators has extensive experience working in a wide range of facilities associated with a variety of hazard classification and design requirements. We are capable of designing equipment for hazardous locations that deal with explosive gases, dusts and other ignitable solids. Additionally, we can design any of our custom elevators â?? whether outdoor, inclined, robotic interface or any others â?? with hazard classifications in mind.
Safi group srl provided explosion-proof elevator and lift equipment for the following types of facilities:
Space shuttle and rocket launch pads
Oil and gas refineries
Coal power plants
Fertilizer plants
Offshore platforms
Safi group srl Provide Explosion Protection
We protect against explosion through a variety of means:
Rated motors and high-voltage electrical equipment NEMA 7 enclosures Purged NEMA 4 controls and equipment where instrument air is available Intrinsically safe control circuits Armored cabling Sealed piping Energy chains and traveling cable management systems to reduce the possibility of breakage
Standards and Requirements
While we primarily design and install to U.S. standards and associated UL compliance requirements, we are familiar with all commonly used hazard classification regimens and their specific requirements:
NEC and NFPA 70 Class, Division and Zone ATEX Zone IECEX Zone
While Mid-American is not ISO-certified, we can provide a robust quality control system tailored to your project to ensure that your elevator or lift product complies with all of your technical and process requirements.
Explosion proof elevators for explosive environments, such as a refinery, combustible substance storage facility, mining facility or other environments with enhanced safety requirements (ATEX and NEC 500).
We produce elevators for these specific environments according to the requirements of the ATEX and NEC 500 standards.
11,800 BTU Cooling/11,200 BTU Heating Through-the-Wall Air Conditioner
Cooling Capacity: Available in various BTUs, such as 8,000, 9,800, 10,000, and 14,000 BTU models
Heating Capability: Many models feature supplemental heating options, providing year-round climate control
Energy Efficiency: High SEER ratings (up to 19), promoting energy savings and reduced utility costs
Quiet Operation: Designed to operate quietly, ensuring minimal disruption in living spaces
Voltage: Available in 115V and 230V configurations
Manufacturer Warranty: up to 5 years
LG Through-the-Wall Air Conditioners provide an efficient solution for cooling and heating spaces without occupying window space. These units are ideal for residential and light commercial applications, offering a sleek design and robust performance.
Knob / Size - L - 5 cm x W - 3 cm x Hight - 5 cm / Shape - Rectangle Shape / Color - White & Brown / Material - Wood, Resin & Metal / Price - 1 USD / Sample Available / Minimum Quantity - 100 Pcs / Packing - Inner & Master Carton Box Export Packing / We can also customize these Knob as per the requirements of our prestigious clients / Interested Buyer Kindly Contact US