Please click here to check who's online and chat with them.

Shengdong Group Dongguan Factory

Supplier From China
Jan-04-12
Supplier : Diesel generator sets, engine accessories

Established: 1998 Standards: ISO1400

Verification Status



Contact Details:
Qishi, Dongping Road
Dongguan 82205
Guangdong China


Recent User Reviews

This user has not received any reviews yet!
 
 
Contact Supplier
Renew

More Items Similiar to: Shengdong Group Dongguan Factory

GOLD Member
Feb-21-25
Supplier From Busan, South Korea (Republic Of Korea)
 
We have 4sets of used Detroit generators that were used as emergency power sources (Standby only) at a municipal water drainage plant in Korea. Please review the attached documents and assess
ENGINE SPECIFICATION
ENGINE MODEL Detroit Diesel 8163-7416 1232HP
ENGINE NO. 16VF013546
RPM 1,800
Cylinder 16
Injection method Direct injection
Cooling method Water Cooled
Fuel consumption rate 246â??/h
GENERATOR SPECIFICATION (AC Generator, 3Ã??, 60Hz, Brushless type
Generator Model DIG 4800
Emergency output 990 kVA / 792 kW
Continuous output 900kVA / 720kW
Voltage and Current 600 v x 86.6 A
Revolution 1800RPM
Excitation Voltage/Current 65V/10A
Power Factor 80%
Insulation Class F
GOLD Member
VERIFIED
Jun-25-25

Small Diesel Generator Sets, 1

$1.00K - $10.00K / Box (CIF)
MOQ: 1  Boxes
Sample Available
Supplier From Weifang, Kuaiwen, China
 
Small diesel generator set is a diesel-fuelled internal combustion engine driven alternator small power generation equipment, power range is usually between 7-30kW, by the diesel engine, generator, control box and fuel tanks and other core components, suitable for emergency power supply or mobile scene.
The units are usually air-cooled, and some models are equipped with water-cooled cooling structure to improve efficiency, and the silent design can control the noise at 65-73dB. The structure integrates shock-absorbing spring base, universal wheels and handles to support mobile deployment. Standard features include voltage/current monitoring, battery starter, and optional ATS automatic switching and remote start. Technical improvements include a spiral tube cooling system with a ventilated electric fan for synergistic cooling, as well as multiple protection mechanisms such as low fuel consumption (205g/kw.h) and automatic voltage regulation [1].

Translated with DeepL.com (free version)
GOLD Member
VERIFIED
Jun-17-25

Brushless Ats Automated Diesel Generator Sets, 1

$1.00K - $10.00K / Box (FOB)
MOQ: 1  Boxes
Sample Available
Supplier From Weifang, Kuaiwen, China
 
Manual start/stop mode - Electronic control panel selects manual mode, one key to start, one key to stop.
Automatic start-stop mode - electronic control panel AUTO one-key automation; utility power outage automatic start,
utility power incoming automatic shutdown.
Emergency stop mode - The unit is equipped with an external emergency stop button safety device, realising one-key stop in emergency.
Backup Start Mode - Car type key ignition start.
Note: To avoid the failure of the electronic control panel to start the unit
and add the standby type double insurance start, in the emergency power outage needs
to use the generator set is more secure!

Translated with DeepL.com (free version)
GOLD Member
Oct-18-24
Supplier From Busan, South Korea (Republic Of Korea)
 
We have a stock of quality, low-life generators from the military
ï?¬ CAT 3408 400kW
ï?¬ CAT C-16 500kW
ï?¬ CAT 3406 350kW (House type)
ï?¬ Cummins VTA-28G5 500kW
ï?¬ Cummins LTA-10 250kW (House Type)
ï?¬ Cummins LTA-10 250kW
ï?¬ Cummins NT85-G3 350kW
ï?¬ Cummins NT85-G3 350kW (House type)
ï?¬ Cummins NT85-G2 300kW
Please study if it is suitable for your market.
Dec-09-22
 
EAP 220
Engine:
Engine Model : 1106A-70TAG4
Stand By kVA: 220
Stand By kW : 176
Prime kVA: 200
Prime kW : 160
Rated Current : 288

Engine
heavy duty diesel engine
12V starter and charge alternator
Replaceable air, fuel and oil filters
Mechanical governor control
Tropical type radiator
Flexible fuel hose
Oil drain valve and extension hose
Industrial type silencer and steel compensator
Maintenance-free starter battery
Water jacket heater
1500 rpm engine speed

Alternat
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm

Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)

Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system

Engine
Engine Model 1106A-70TAG4
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 16:01
Bore 105
Strok 135
Displacement Lt 7,01
Air Intake Turbocharged and air charge cooled
Speed (RPM) 1500
Oil Capacity Lt 18
Standby Power kw / Hp 196.3 / 265
Prime Power Hp 178.9 / 242
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity Lt 22
Fuel Consumption (lt / h) Lt Full Load 45,8
Lt %75 LOAD 34,7
Lt %50 LOAD 23,1

Frequency Hz
Power kVA 200
Voltage V 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
DIMENSIONS
Weight (Silent) Kg 2270
Weight (Open) Kg 1940
Width (Silent) Mm 1200
Length (Silent) Mm 3500
Height (Silent) Mm 1850
Fuel Tank Capacity Lt 360

1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Dec-08-22
 
EAP 200
Engine Model : 1106A-70TAG3
Stand By kVA: 200
Stand By kW : 160
Prime kVA: 182
Prime kW : 145
Rated Current : 262

Engine
heavy duty diesel engine
12V starter and charge alternator
Replaceable air, fuel and oil filters
Mechanical governor control
Tropical type radiator
Flexible fuel hose
Oil drain valve and extension hose
Industrial type silencer and steel compensator
Maintenance-free starter battery
Water jacket heater
1500 rpm engine speed

Alternat
IP 21-23 Protection Standard
H Insulation Class
50 Hz Frequency
4 pole brushless synchronous type alternator
Automatic Voltage Regulator (AVR)
400/230V AC Output Voltage - 1500 rpm

Sound Proof Canopy and Chassis
Convenient design for easy lifting and carrying
High standard sound proof canopy design
Modular design with easily removable nuts - bolts
Lockable doors
Transparent window for watching Control Panel
Electrostatic powder painted, providing protection against harsh weather conditions
Emergency STOP button
Fuel tank inside the chassis
Anti-vibration wedges (engine - chassis and chassis ground)

Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system

Engine Model 1106A-70TAG3
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 16:01
Bore 105
Strok 135
Displacement Lt 7,01
Air Intake Turbocharged and air charge cooled
Speed (RPM) 1500
Oil Capacity Lt 16,5
Standby Power kw / Hp 180.2 / 243,5
Prime Power Hp 162.7 / 220
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity Lt 22
Fuel Consumption (lt / h) Lt Full Load 41,5
Lt %75 LOAD 31,8
Lt %50 LOAD 20,2

Frequency Hz
Power kVA 200
Voltage V 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8

Weight (Silent) Kg 2190
Weight (Open) Kg 1850
Width (Silent) Mm 1200
Length (Silent) Mm 3500
Height (Silent) Mm 1850
Fuel Tank Capacity Lt 360

1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Oct-20-22
 
EAP 33
Engine: PERKNS
Engine Model : 1103A-33G
Stand By kVA: 33
Stand By kW : 26,4
Prime kVA: 30
Prime kW : 24
Rated Current : 43,2

Engine
heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed

Alternat
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm

Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)

Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system

Engine PERKNS
Engine Model 1103A-33G
Number of Cylinders 3 Inline
Injection System Direct
Compression Ratio 19.25:1
Bore 105
Strok 127
Displacement Lt 3,3
Air Intake Naturally Aspirated
Speed (RPM) 1500
Oil Capacity Lt 8,3
Standby Power kw / Hp 30,4 / 41
Prime Power Hp 27,7 / 37,3
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity Lt 8
Fuel Consumption (lt / h) Lt Full Load 7,2
Lt %75 LOAD 5,6
Lt %50 LOAD 4

Frequency Hz
Power kVA 33
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8

Weight (Silent) Kg 980
Weight (Open) Kg 825
Width (Silent) Mm 900
Length (Silent) Mm 2200
Height (Silent) Mm 1350
Fuel Tank Capacity Lt 135

1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
GOLD Member
VERIFIED
Jun-23-25

Zbcy150-200-15 Mobile Silent Diesel Pump, 1

$100 - $2.00K / Box (CIF)
MOQ: 1  Boxes
Sample Available
Supplier From Weifang, Kuaiwen, China
 
Q=200m3/h, H=15m,DN150, cast iron material

With integral silent cabinet 80db at 7 meters
Display: speed, water temperature, oil pressure, and with overspeed, high water temperature, low oil pressure alarm stop function
DN150 quick coupling
Diesel tank 50L
In the case of the same parameters, the equipped pump is the same as the diesel engine, the response size is not different, and the 40HQ cabinet can only be installed 4 sets. The length of the second round is not much smaller.
Dec-16-22
 
FP 250
Engine
Engine Model : 1206A- E70TTAG2
Stand By kVA: 250
Stand By kW : 200
Prime kVA: 227
Prime kW : 182
Rated Current : 327

Engine
heavy duty diesel engine
12V starter and charge alternator
Replaceable air, fuel and oil filters
Mechanical governor control
Tropical type radiator
Flexible fuel hose
Oil drain valve and extension hose
Industrial type silencer and steel compensator
Maintenance-free starter battery
Water jacket heater
1500 rpm engine speed

Alternat
IP 21-23 Protection Standard
H Insulation Class
50 Hz Frequency
4 pole brushless synchronous type alternator
Automatic Voltage Regulator (AVR)
400/230V AC Output Voltage - 1500 rpm

Sound Proof Canopy and Chassis
Convenient design for easy lifting and carrying
High standard sound proof canopy design
Modular design with easily removable nuts - bolts
Lockable doors
Transparent window for watching Control Panel
Electrostatic powder painted, providing protection against harsh weather conditions
Emergency STOP button
Fuel tank inside the chassis
Anti-vibration wedges (engine - chassis and chassis ground)

Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system

Engine
Engine Model 1206A- E70TTAG2
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 15.08:1
Bore 105
Strok 135
Displacement Lt 7,01
Air Intake Turbocharged aftercooled
Speed (RPM) 1500
Oil Capacity Lt 16,5
Standby Power kw / Hp 226 / 303
Prime Power Hp 204 / 273
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity Lt 25
Fuel Consumption (lt / h) Lt Full Load 50,6
Lt %75 LOAD 37,9
Lt %50 LOAD 25,2

Frequency Hz
Power kVA 200
Voltage V 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8

Weight (Silent) Kg 2550
Weight (Open) Kg 2120
Width (Silent) Mm 1300
Length (Silent) Mm 3900
Height (Silent) Mm 1980
Fuel Tank Capacity Lt 450

1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.

Verification Status