EA16 is the extension of EA15 product design, inherited the EA15 wide voltage detection range and power supply voltage, and enhanced the generator as the parallel performance when using parallel system, in addition to current compensation input by the user can choose 1A or 5A than CT input number, can be provided by the system to an analog signal change the terminal voltage of generator. EA16 in the protection of increase of over excitation voltage protection, the protection to prevent detection power disconnection and generator excitation is abnormal, the protection function can also be removed. EA16 / EA16-400Hz (detection voltage 400Hz) universal 16Amp parallel generator automatic voltage regulator compatible models: Marelli, Caterpillar, Khenkikian, Genaust and other brands of AVR

* this page AVR the name of the manufacturer, type is only for reference, this page product is not the original products, AVR products but consistent with the original products

Product features

Voltage regulation rate < ¡À 0.5%?

Application of VAC? 170~510 brushless generator

Can be used in parallel unit?

? 16 ADC output current

Application of 50/60 Hz? EA16 frequency, EA16-400Hz frequency of 400 Hz

? with low-frequency protection and voltage slow up function

? with load current compensation, analog voltage input function

Product specifications

The product model

EA16 / EA16-400Hz*

Detection of input

Voltage: 170~510 VAC single-phase two-wire

Frequency: 50/60 Hz

The frequency of *EA16-400Hz: 400 Hz

Power input

Voltage: 60~300 VAC single-phase two-wire

Field output

Voltage: 240 VAC input, 90 VDC

Current: continuous discontinuous 16A 20A for 10 seconds

Resistance: a minimum of 6 Ohm @ 35 VDC

The external voltage adjustment

¡À 0.5% (engine speed variation in 4%)

Voltage is established

In the AVR input terminal to remanence voltage above 5 VAC

The external voltage adjustment

With 2 K Ohm 1 watt potentiometer is ¡À 5%

Power consumption

A maximum of 10 Watt

Temperature stability

Every C change, 0.03% voltage drift

Low frequency protection

55 Hz @ 60 Hz, 45 Hz @ 55 Hz (adjustable)

*EA16-400Hz: 360 Hz (adjustable)

Current compensation input

1A or 5A (optional)

Analog voltage input

¡À 5 VDC ¡À 10% AC @ 3 VDC

Work environment

Operating temperature: -40~70 degrees C

The storage temperature: -40~85 degrees C

Relative humidity: 95%

Vibration: 3.3G @ 100~2 KHz

Characteristics of the adjusting knob

VOLT: adjusting voltage

STAB: adjust stability

U/F: adjust the low-frequency protection point

DROOP: adjust current compensation voltage drop

TRIM: analog voltage effect of ratio adjustment

Size




Unit Type:piece Package Weight:1.000kg (2.20lb.) Package Size:19cm x 18cm x 17cm (7.48in x 7.09in x 6.69in)