EA16 is the extension of EA15 product design, inherited the EA15 wide voltage detection range and power supply voltage, and enhanced the generator as the parallel performance when using parallel system, in addition to current compensation input by the user can choose 1A or 5A than CT input number, can be provided by the system to an analog signal change the terminal voltage of generator. EA16 in the protection of increase of over excitation voltage protection, the protection to prevent detection power disconnection and generator excitation is abnormal, the protection function can also be removed. EA16 / EA16-400Hz (detection voltage 400Hz) universal 16Amp parallel generator automatic voltage regulator compatible models: Marelli, Caterpillar, Khenkikian, Genaust and other brands of AVR
* this page AVR the name of the manufacturer, type is only for reference, this page product is not the original products, AVR products but consistent with the original products
Product features
Voltage regulation rate < ¡À 0.5%?
Application of VAC? 170~510 brushless generator
Can be used in parallel unit?
? 16 ADC output current
Application of 50/60 Hz? EA16 frequency, EA16-400Hz frequency of 400 Hz
? with low-frequency protection and voltage slow up function
? with load current compensation, analog voltage input function
Product specifications
The product model
EA16 / EA16-400Hz*
Detection of input
Voltage: 170~510 VAC single-phase two-wire
Frequency: 50/60 Hz
The frequency of *EA16-400Hz: 400 Hz
Power input
Voltage: 60~300 VAC single-phase two-wire
Field output
Voltage: 240 VAC input, 90 VDC
Current: continuous discontinuous 16A 20A for 10 seconds
Resistance: a minimum of 6 Ohm @ 35 VDC
The external voltage adjustment
¡À 0.5% (engine speed variation in 4%)
Voltage is established
In the AVR input terminal to remanence voltage above 5 VAC
The external voltage adjustment
With 2 K Ohm 1 watt potentiometer is ¡À 5%
Power consumption
A maximum of 10 Watt
Temperature stability
Every C change, 0.03% voltage drift
Low frequency protection
55 Hz @ 60 Hz, 45 Hz @ 55 Hz (adjustable)
*EA16-400Hz: 360 Hz (adjustable)
Current compensation input
1A or 5A (optional)
Analog voltage input
¡À 5 VDC ¡À 10% AC @ 3 VDC
Work environment
Operating temperature: -40~70 degrees C
The storage temperature: -40~85 degrees C
Relative humidity: 95%
Vibration: 3.3G @ 100~2 KHz
Characteristics of the adjusting knob
VOLT: adjusting voltage
STAB: adjust stability
U/F: adjust the low-frequency protection point
DROOP: adjust current compensation voltage drop
TRIM: analog voltage effect of ratio adjustment
Size
Unit Type:piece Package Weight:1.000kg (2.20lb.) Package Size:19cm x 18cm x 17cm (7.48in x 7.09in x 6.69in)