Please click here to check who's online and chat with them.

Find Verified Split Core Current Sensors Suppliers, Manufacturers and Wholesalers

Apr-25-11
 
Type : RTCS050EK1, RTCS100EK1, RTCS200EK1, RTCS300EK1, RTCS400EK1, RTCS500EK1
IPN : Primary nominal input current : 50, 100, 200, 300, 400, 500A
IP Measuring range of primary current : 0~¡À100, 0~¡À200, 0~¡À400, 0 ~¡À600, 0~¡À800, 0~¡À1000 A
VOUT Nominal output voltage : 4¡À1%V
VC Supply voltage : ¡À12~¡À15(¡À5%)V


20 pcs/inner,200 pcs/CTN,14.5 KGS,40x25x30CM.
Jul-26-18
Supplier From Guang Dong, Guang Zhou, China
 
Main Features 1.Small size, low cost 2.High secondary turns 3.Secure locking hinge
Model No: MEWOI-CT10,16,24,36,50
Name: MEWOI-CT10,16,24,36,50 Split Core Current Sensor/Transformer

Rated Current:5A to 600A loads
Rated output:0.333Vac
Current Ratio:3000:1
Insulation Voltage:600Vac
Maximum Primary Voltage:5000Vac(Insulated Conductor)
Operating Temperature:-15 to 60
Frequency Range:50-400Hz
Leads:4Foot (105cm), UL 1015, Twisted Pair,0.34mm2(22AWG)
Output and leads:can be customized
Application 1.Sub-Metering Accurate Measurement
2.Data Loggers to analyze Building & Machinery Performance
3.Digital Fault Recorders
4.Smart Grid Application Features Load Center
5.Three Phase Balance Control
6.In-Factory Display In-Home Display
7.Inverters for Solar & Wind Turbine Systems
8.Power Measurement Device For PLC
Aug-13-24
 
The CIT series high precision split core current transducer is developed by Hangzhi based on the fluxgate technology and can realize the isolated measurement of DC current and AC current.

Measuring range: from �±100A to �±1500A.
Accuracy: 0.05%.
Linearity: 0.02%.
Hole diameter: 40mm.
Zero offset current/I: �±30uA.
Operating temperature: -30�­�°C~75�­�°C.
Bandwidth (3dB): 350kHz.
Response time: 2us.

The non-intrusive installation of a CIT split-core fluxgate current transducer is one of its key advantages. There is no need to disrupt the circuit by simply clamping the device around the conductor, making it a feasible alternative for monitoring existing systems without generating downtime.

These transducers are used in a variety of applications, including power distribution, energy management, industrial automation, and others. They are critical in allowing for efficient energy use, monitoring electrical systems, and guaranteeing safe and reliable operation.
Jul-26-18
Supplier From Guang Dong, Guang Zhou, China
 
Main FeatureS: small DC leakage current measurement
Model No.: MEWOI-DRSL(DC)2000mA
Name: MEWOI-DRSL(DC)-2000mA Leakage current sensor
Diameter: Ï?33mm
Rated input Current (IPN)50 100 500 1000 2000 mA(DC)
Primary Current Measure range(IP) :0100 0150 0600 01200 02200mA
Rated output voltage of secondary side DC ±5V 4-20mA 0-20m
Power Supply Voltage �VCC� DC ±12V15V
Current consumption
Aug-04-16
Supplier From Yueqing, China
55962 Split Core Current Sensors Suppliers
Short on time? Let Split Core Current Sensors sellers contact you.
Aug-05-16
 
HK Series split core current transformer is HEYI Electrical current transformer manufacturer newly developed products and the
split core CT are designed in particular for esay installation, the quick release button makes the ct the most convenient to fit around
cables without cutting off the circuitry. HK current transformer has advantages of bigger capacity and bigger mounting hole size,
could be used in more power applications.
Aug-05-16
 
HACT series provide precision measurement for energy monitoring applications to sensing power loading equipment without interrupting the lines. It has been specifically designed to be easy to open and yet maintain the accuracy required for intelligent meters, quick to fit around cables.
Aug-05-16
 
SCT range of split core current transformers have been specially designed to facilitate their installation in new or already existing net works.
They may be installed without opening any cable or bus-bar circuit. An ineternal precision resistor across the secondary winding of the ct provides
a low safe voltage output.
Aug-05-16
 
UK Series split-core current transformer has been specially designed to facilitate their installation in new or already existing networks.
They may be installed without opening any cable or bus-bar circuit.An internal precision resistor across the secondary winding of the CT provides a low safe voltage output.It can save time and the installations costs.
Features
Doubie-screw fastening,safe,easy to install,portable.
Wide inner window,allowing clamping of big cables or bus-bars.
Wide range of sizes to accommodate all the existing installations.
Application
Current measurement,monitoring and protection for electrical wiring and equipment.
Current and power measurement for electric motors,lighting,air compressor,heating and ventilation system,air-condition equipment and automation-control system.
Current,power and energy monitoring device.
Relay protection device
Aug-05-16
 
The KCT range of split core current transformers have been specifically designed to be small CT and easy to open and yet maintain the accuracy required for kwh meters. The benefit of a split core current transformer is that it can be placed into position easily and without disturbing or disconnecting the main cables it is monitoring. The KCT range of current transformers has two insulated terminal covers for connecting the S1 and S2 cables which lock down over the terminal screws fully insulating the connections. This makes it ideal to use Autometers cable hamesses which are colour coded and individually numbered on each conductor ensuring simple and easy connection from the current transformer to the electricity meter.
Aug-05-16
 
The KCT range of split core current transformers have been specifically designed to be small CT and easy to open and yet
maintain the accuracy required for kwh meters. The benefit of a split core current transformer is that it can be placed
into position easily and without disturbing or disconnecting the main cables it is monitoring.
Aug-05-16
 
1:The structure of the self-locking, safe, easy to install, portable
2:Wide inner window, allowing clamping of big cables or bus-bars
3:Wide range of sizes to accommodate all the existing installations
4:Isolated plastic case recognized according to UL94-V0
5:Wires plugs,Audio plugs,Power plugs and so on five kinds of plugs
1:Current measurement, monitoring and protection
for electrical wiring and equipment.
2:Current and power measurement for electric motors, lighting, aircompressor,heating and ventilation system, air-condition equipment and automation – control system.
3:Current, power and energy monitoring device.
4:Relay protection device.
Aug-05-16
 
Flexible Rogowski coil split core Current Transformer is an AC current transducer for permanent installation. They combine the benefits of a thin, flexible, clip-around Rogowski (sense) coil with a signal conditioner providing accurate, true rms measurement, of voltage or current.
Aug-05-16
 
KCT-23 clamp on current transformer has been designed to be circular and for specific occasions, clip-on design could be installed
without opening any cable or bus-bar circuit. Its capacity becomes bigger compared with KCT, SCT series.
Aug-05-16
 
DASN series three phase current transformer development of DAS series,use it in primary current 60A-1600A electric circuit ,
Supporting the use of plastic shell breaker.
Aug-05-16
 
D363 & D364 range of current transformers are combination designed 3 CT in 1, save more space comparing general unit CT,
suitable for primarycurrent 75A to 600A, supporting the use of molded case circuit breaker according to

the rated current size.
Aug-05-16
 
Epoxy Potting,Double-screw fastening,safe,easy to install,portable.
Wide inner window,allowing clamping of big cables or bus-bars.
Wide range of sizes to accommodate all the existing installations.
Conforms to IEC185,BS7626,BSEN60044-1 and IEC60044-1.
Aug-05-16
 
MSQ range of current transformers can be applied to test,control,display and record the running of the electrical
equipment,and to protect the equipment against the damage,in the AC circuit with the rated voltage value below 720V
and the frequency of 50-60Hz.The product can be also applied to form a complete set of mine transformer
Feature:

1: Safe. Easy to install, porttable
2:Wide inner window, allowing clamping of big cables or bus-bars
3:Wide range of sizes to accommodate all the existing installations
Application
1:Current measurement, monitoring and protection for electrical wiring and equipment
2:Current and power measurement for electric motors, lighting , air compressor , heating and ventilation system, air-condition equipment and automation-control system
3: Current , power and energy monitoring device.
4: Relay prtection device.
Aug-05-16
 
Epoxy Potting,Double-screw fastening,safe,easy to install,portable.
Wide inner window,allowing clamping of big cables or bus-bars.
Wide range of sizes to accommodate all the existing installations.
Conforms to IEC185,BS7626,BSEN60044-1 and IEC60044-1.
Aug-05-16
 
MBO Series (9 frames) perfect designed plastic case current transformer, advanced snap on body, high accuracy (up to Class 0.2S),
humanization transparent cover and lead seal hole design makes the CT very easy to indentify after long term use and perfect
anti-stealing electricity.
Features
1:Safe, easy to install, portable
2:Wide inner window, allowing clamping of big cables or bus-bars
3:Wide range of sizes to accommodate all the existing installations
Applications:
1:Current measurement, monitoring and protection for electrical wiring and equipment.
2:Current and power measurement for electric motors, lighting, air compressor, heating and ventilation system, air-condition equipment and automation - control system.
3:Current, power and energy monitoring device.
4:Relay protection device.
55962 Split Core Current Sensors Suppliers
Short on time? Let Split Core Current Sensors sellers contact you.