The Portable single-phase electric meter Test Equipment is used for grid corporation of measurement and energy test center, management department of power supply bureau, national energy measurement of testing authorities, and also used to test each kind of single phase kWh meter of industries and mining enterprises as well as electric meter manufacturers. Meanwhile, the calibrator also can be used as one high precision standard power source, ac voltage source and current source.
The Portable single-phase electric meter Test Equipment is used for grid corporation of measurement and energy test center, management department of power supply bureau, national energy measurement of testing authorities, and also used to test each kind of single phase kWh meter of industries and mining enterprises as well as electric meter manufacturers. Meanwhile, the calibrator also can be used as one high precision standard power source, ac voltage source and current source.
GF102 series portable single phase energy meter test bench used to test 1pc or 3pcs single phase energy meter or AC meter at same time. Adopt mature signal synthetic and power amplifier technology, high precision voltage source and current source output from 120A/600V. Widely used in lab and field, and then as single phase standard source. It is suite for electricity meter manufacturing enterprises, scientific research institutes, metrological service institutions, electric power companies etc.
GF1021 single phase portable energy meter test system used to test single phase energy meter error. Adopt mature signal synthetic and power amplifier technology, high precision voltage source and current source output. Widely used in lab and field, and then as single phase standard source. The portable meter test equipment offers high functionality combined with an excellent menu guided operation via coloured 7 touch screen or externally via interface.
Snt 1100 single phase meter test bench is widely used in power utilities,¡émeter manufacturer,¡émeasurement/quality test lab and other enterprises to test single phase energy meter.
18639 Portable Single Phase Electric Meter Test Suppliers
Short on time? Let Portable Single Phase Electric Meter Test sellers contact you.
Overview:
The RT6103-S Single Phase Energy Meter Test Instrument (Split Type) adopts internationally advanced new-generation digital power source technologt, integrates all the technological advantages of both domestic and foreign watt-hour meter calibration software, and is introduced to global market by Rowwin Test in a powerful and sensational way. The single phase energy meter test instrument comprises of PWM power source, standard digital energy meter,error processor and PC processing software, this energy meter test instrument can test 3 to 60 various watt-hour meters of Grade 0.5 or lower simultaneously, also is an ideal new-generation multi-position energy meter testing instrument.
Technical Parameters:
1. Accuracy class: 0.1/0.05.
2. Reference standard energy meter£ºSingle phase wide-measurement range standard energy meter.(Accuracy class:0.1/0.05). Multi-path voltage transformer: Accuracy class:0.01; Rated load per path:10VA.
3. Voltage range:220v(240V option),Output range:0~125%,Resolution:0.01%full range.
4. Current measurement range:0.1~100A(200A option),Output range:0~120%,Resolution:0.0001A(minimum)
5. Phase angle:0~360¡ã,Resolution of phase angle setting:0.01¡ã.
6. Frequency:45Hz~65Hz,Resolution:0.01Hz.
7. Output waveform distortion:Both voltage and current<0.5%.
8. Output voltage,current and power stability:<0.05%.
9. Output capacity:Current:1,000VA(120A);Voltage:400VA(24 meter testing positions). If necessary,the maximum load can be extended to Current:1,800VA and Voltage:1,000VA.
10. Load characteristics:Resistive,inductive and capacitive(less than 4uF).
11. Starting current output:5mA(minimum);Accuracy:5%;Starting power:Accuracy 5%.
12. Energy meter testing positions:24/48 standard (3 ~60 meter positions also available).
13. Testing functions:Accuracy testing,Creep testing(no load testing),Starting up testing,Harmonic testing,Repeatability testing, Influencing testing,Dial testing and etc.
14. Input power supply:220VAC,¡À10%,50Hz;Max.power consumption:1,500VA(24 meter testing positions).
Dimension:
24 meter testing positions(1 rack): 2200*700*1920mm.
48 meter testing positions(2 racks): 2200*700*1920mm each.
Cabinet: 600*800*1600mm.
Overview:
The RT6103B Multi-function single phase energy meter test instrument adopts internationally advanced new-generation digital power source technology, integrates all the technological advantages of both domestic and foreign watt-hour meter calibration software, and is introduced to global market by Rowwin Test in a powerful and sensational way. The Multi-function single phase energy meter test instrument comprises of PWM power source, standard digital energy meter, error processor and PC processing software, this energy meter test instrument can test 3 to 60 various watt-hour meters of Grade 0.5 or lower simultaneously, also is an ideal new-generation multi-position energy meter testing instrument.
Technical Parameters:
1. Accuracy class: 0.1/0.05
2. Reference standard energy meter£ºSingle phase wide-measurement range standard energy meter(Accuracy class:0.1/0.05), Multi-path voltage transformer: Accuracy class:0.01;Rated load per path:10VA.
3. Voltage range:220v(240V option),Output range:0~125%,Resolution:0.01%full range.
4. Current measurement range:0.1~100A(200A option),Output range:0~120%,Resolution:0.0001A(minimum).
5. Phase angle:0~360¡ã,Resolution of phase angle setting:0.01¡ã.
6. Frequency:45Hz~65Hz,Resolution:0.01Hz.
7. Output waveform distortion: Both voltage and current<0.5%
8. Output voltage, current and power stability:<0.05%
9. Output capacity:Current:1,000VA(120A);Voltage:400VA(24 meter testing positions). If necessary, the maximum load can be extended to Current:1,800VA and Voltage:1,000VA.
10. Harmonic wave output: 2-21st sub-harmonic wave, content<40%; 3rd,5th and 7th superposed sub-harmonic wave, content<10% each;Control of conduction angle(odd sub-harmonic wave);Control of wave group(sub-harmonic wave).
11. Load characteristics: Resistive, inductive and capacitive(less than 4uF)
12. Starting current output:5mA(minimum); Accuracy:5%;Starting power: Accuracy 5%
13. Energy meter testing positions:24/48 standard ;3 to 60 meter positions also available
14. Testing functions: Accuracy testing, Creep testing(no load testing),Starting up testing, Harmonic testing, Repeatability testing, Influencing testing, Dial testing and etc.
15. Input power supply:220VAC,¡À10%,50Hz. Max power consumption:1,500VA(24 meter testing positions).
16. Tests: Demand test; Frequency impact test; Voltage impact test; Second pulse clock precision test; GPS clock synchronization; Constant calibration; Combined error test; Various register checking;RS485 communication port test.
Dimension:
Integral Type
24 Meter testing positions(1 rack): 2200*750*1920mm
48 Meter testing positions(2 racks): 2200*750*1920mm.
The RT6103F Anti-tamper Single Phase Energy Meter Test Instrument adopts internationally advanced new-generation digital power source technology, integrates all the technological advantages of both domestic and foreign watt-hour meter calibration software, and is introduced to global market by Rowwin Test in a powerful and sensational way. The Multi-function single phase energy meter test instrument comprises of PWM power source, standard digital energy meter, error processor and PC processing software, this energy meter test instrument can test 3 to 60 various watt-hour meters of Grade 0.5 or lower simultaneously, also is an ideal new-generation multi-position energy meter testing instrument.
Technical Parameters:
1. Accuracy class: 0.1/0.05
2. Reference standard energy meter£ºSingle phase wide-measurement range standard energy meter.(Accuracy class:0.1/0.05)Multi-path voltage transformer: Accuracy class:0.01; Rated load per path:10VA
3. Voltage range:220v(240V option),Output range:0~125%,Resolution:0.01%full range
4. Current measurement range:0.1~100A(200A option),Output range:0~120%,Resolution:0.0001A(minimum)
5. Phase angle:0~360¡ã,Resolution of phase angle setting:0.01¡ã
6. Frequency:45Hz~65Hz,Resolution:0.01Hz
7. Output waveform distortion: Both voltage and current<0.5%
8. Output voltage, current and power stability:<0.05%
9. Output capacity:Current:1,000VA(120A);Voltage:400VA(24 meter testing positions)If necessary ,the maximum load can be extended to Current:1,800VA and Voltage:1,000VA
10. Load characteristics: Resistive, inductive and capacitive(less than 4uF)
11. Starting current output:5mA(minimum); Accuracy:5%;Starting power: Accuracy 5%
12. Energy meter testing positions:24/48 standard ;3 to 60 meter positions also available
13. Testing functions: Accuracy testing for Phase loop & Neutral loop, Creep testing(no load testing),Starting up testing, Harmonic testing, Standard deviation testing ,Influencing testing, Dial testing, Repeatability testing, Neutral cut off testing and etc.
14. Input power supply:220VAC,¡À10%,50Hz;Max power consumption:1,500VA(24 meter testing positions).
15. Online calibration can be conducted on 1P2W single loop watt-hour meter and also offline calibration on the three kinds of loop can be performed such as 1-2,4-3,1-2-4-3(or 1-4,3-2,1-4-3-2).
Dimension:
24 Meter testing positions(1 rack): 2200*750*1920mm.
48 Meter testing positions(2 racks): 2200*750*1920mm.
Introduction
GF1021 portable single phase energy meter test system used to test single phase energy meter. Adopt mature signal synthetic and power amplifier technology, high precision voltage source and current source output. Widely used in lab and field, and then as single phase standard source.
TECHINICAL SPECIFICAITON
Accuracy class 0.05%, 0.1%
Power supply One Phase AC 85-265V, frequency 50/60Hz.
AC Voltage output
Range 57.7V, 100V, 220V, 380V; max 500V
Adjustment range (0-120)%RG(1)
Adjustment fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability 0.01%/120s
Distortion 0.1% (Non-capacitive load)
Output load max 30VA
Measuring accuracy 0.05%RG
AC Current output
Range 200mA, 1A, 5A, 20A, 100A; max 120A
Adjustment range (0-120)%RG
Adjustment fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability
The GF302D1 three phase portable energy meter test equipment consists of an integrated three phase current source(up to 500V/120A or 500V/20A) and built-in three-phase electronic reference standard of accuracy class 0.05%. Characteristic features of the GF302D1 are its wide measuring range, high accuracy and high tolerance to unwanted external influences. The equipment offers high functionality combined with an excellent menu guided operation via built-in keyboards and colored 7" touch LCD-display. Voltage & current harmonics output from 2 to 63 times. This model portable meter test equipment can be programmable by PC, automatic generation of energy meter error test report.
Main usages:
Designed for timesharing electricity metering of new or reconstructed single-phase users. With prepayment function, it is particularly suitable to solve payment-collecting difficulties in residential area, organization, factories, mines and schools excite is preferable in promoting the management level at demand side, inducting the users to better power consumption style to improve power efficiency and electric sources collocation.
Main Functions
1.Both-way electric energy metering. Provides precise positive-negative active energy metering and one-way accumulating. Used for power metering and advance purchase of AC single-phase current rated.
2.Advance purchase quantity, preset maximum load-limit and IC card password. IC card transfers data and realizes data including total consumption, remaining quantity, accumulated quantity and total purchases etc.)backward reading.
3.Storage of leave-factory serial number, meter constants, initial data and the user's name and address etc..
4.Alarm and switch off when overload. Alarm at low remaining power to remind user of timely purchasing.
Main Characteristics:
1.High accuracy and import special metering chip. High accuracy, sensitivity and reliability, wide overload endurance, low power consumption, small volume and light in weight; easy installation, convenient auto-control and function expanding.
2.Long service life. With SMT technology and world famous, long-life components employed, its accuracy is not affected by frequency, temperature, voltage and higher order harmonics. Random installation location. No adjustment is needed if it leaves the factory as complete machine. Checkout period can be extended. Hence the workload of Watt-hour Meter testing and checking-out of electric departments is considerably reduced. Obviously better reliability than its similar.
3.Stable operation. Better stability for its wide range working voltage.
4.LED display, bright and clear prevent counter data from Losing at any times.
5.Single-phase,3-phase and multi-functional prepayment Watt-hour Meter can share a single electricity supply system.
6.With meter reading card and a portable computer, once about 1500 meters can be read.
Single-phase electric meter field calibrator is suitable to test various types single phase meters on site and can also be used to test alternating current parameters.
Feature
1. Current clamp and meter combined together, colorful and touch-screen display;
2. One AAA Li-battery can continuously working 4 hours;
3. Wide voltage, current measurement range, voltage range: 15-300V, current range: 0.05-120A;
4. Display all the measuring parameters in one screen;
5. Current clamp has automatic compensation function, 0.2% class accuracy;
6. Current clamp has automatic calibration function;
7. Integration design of the meter and clamp;
8. 16bit high accuracy AD switch 32 bit ARM processor core.
9. Automatically record and save 999 groups calibrate data;
10. Micro-multifunction optic sampler
Technical index
1. Manual/automatic test inductive single phase meters;
2. Manual/automatic test electric single phase meters;
3. Measure virtual value of alternating voltage (15~300Vrms);
4. Measure virtual value of alternating current (50mA~120Arms);
5. Test parameters: active power, phase angle of voltage and current, frequency and etc;
6. Automatic store testing data, and 999 group test results can be saved.
Our STS prepaid electricity meter is certificated by STS association that is from South Africa. The meter is built-in prepayment algorithm, will cut off the power automatically if the credit in the meter be used up. And will reconnect automatically if the meter recharge for his meter. This kind of meter is very popular on the Africa and Asia, Nigeria, Tanzania, Ghana, Syria Indonesia, installing millions of STS keypad prepaid electricity meter.
Our STS prepaid electricity meter is certificated by STS association that is from South Africa. The meter is built-in prepayment algorithm, will cut off the power automatically if the credit in the meter be used up. And will reconnect automatically if the meter recharge for his meter. This kind of meter is very popular on the Africa and Asia, Nigeria, Tanzania, Ghana, Syria Indonesia, installing millions of STS keypad prepaid electricity meter.
1. Check the error of active and reactive of watt-hour meter at the same time, and meanwhile check the error of main and secondary meter in the same circuit.
2. Display the electrical constants such as: voltage, current, power, power factor, phase and frequency and etc.
3. Measure ct ratio, wave form display.
4. Measure 2-51 voltage and current harmonics.
5. Judge wrong wiring.
6. Measure the baud rate for multi-function energy meter and meter number reading.
2.Measuring the different constant meters synchronously.
3.With the protect function of overload, short voltage circuit and open current circuit.
4.The testing software with friendly windows 2000 and xp interface, include functional module of all kinds of modern energy meter needed, to reality error test, harmonic test, demand test, influence test.
5.The stored testing data can be transferred to multi-format for other program using
18639 Portable Single Phase Electric Meter Test Suppliers