Zirconia O2 Sensors
Probe Series - Short Housing

The Probe Range of zirconium dioxide oxygen sensors are available in three lengths. Suitable for aggressive and polluted applications such as boiler exhausts. Longer probes are an ideal solution for thicker walled, insulated flue pipes.

FEATURES
* Zirconium dioxide (ZrO2) sensing elements
* Long life, non-depleting technology
* Integral heating element
* High accuracy
* Requires an external interface board to operate

BENEFITS
* No reference gas required
* No need for temperature stabilisation
* Compact enclosure

TECHNICAL SPECIFICATIONS
Heater voltage
Operating (standard response) 4V DC ± 0.1V DC (1.7A)
Standby 1.65V DC (0.7A)
Operating (fast response) 4.35V DC ± 0.1V DC (1.85A)
Standby 2V DC (0.85A)
Pump impedance at 700'C < 6kΩ
Permissible gas temperature -100'C to +250'C
Gas flow rate 0 ~ 10 m/s
Repetitive permissible acceleration 5g
Incidental permissible acceleration 30g

OUTPUT VALUES
Oxygen pressure range 2mbar ~ 3bar max
Accuracy 5mbar max
Internal operational temperature 700'C
Response time (10 - 90% step)
Standard response sensor < 15s
Fast response sensor < 4s
Warm up time (prior to sensor operation) 60s
Warm up time (from standby) 20s
Output stabilisation time ~ 180s
Dec-02-16
Supplier From Shenzhen, Guangdong, China
 
Features
* oxygen pressure range 2 mbar - 3bar
* zirconium dioxide (zro2 ) sensing elements
* non-consumption technology
* integral heating element
* no need for temperature stabilisation
* no reference gas required
* high accuracy
* linear output signal
* operates with external interface boards
* 80mm, 220mm and 400mm probes available

Specifications
Heater supply*
Porous lid cap 4v dc +/- 0.1v dc (1.7a)
Stand by 1.65v dc (0.7a)
Full porous cap 4.35v dc +/- 0.1v dc (1.85a)
Stand by 2v dc (0.85a)
Jun-02-17
Supplier From Shenzhen, Nanshan, China
 
Zirconia O2 Sensors
Probe Series - Long Housing

FEATURES
* Zirconium dioxide (ZrO2) sensing elements
* Long life, non-depleting technology
* Integral heating element
* High accuracy
* Requires an external interface board to operate

BENEFITS
* No reference gas required
* No need for temperature stabilisation
* Two lengths available; 220mm and 400mm

TECHNICAL SPECIFICATIONS
Heater voltage
Operating 4V DC ± 0.1V DC (1.7A)
Standby 1.65V DC (0.7A)
Pump impedance at 700'C < 6kohm
Permissible gas temperature
Standard temperature -100'C to +250'C
High temperature -100'C to +400'C
Gas flow rate 0 - 10 m/s
Repetitive permissible acceleration 5g
Incidental permissible acceleration 30g

OUTPUT VALUES
Oxygen pressure range 2mbar - 3bar max
Accuracy 5 mbar max
Internal operational temperature 700'C
Response time (10 - 90% step) < 15s
Warm up time (prior to sensor operation) 100s
Warm up time (from stand by) 20s
Output stabilisation time ~ 180s
Dec-02-16
Supplier From Shenzhen, Guangdong, China
 
Features
* oxygen pressure range 2 mbar - 3bar
* zirconium dioxide (zro2) sensing elements
* non-consumption technology
* integral heating element
* no need for temperature stabilisation
* no reference gas required
* high accuracy
* linear output signal
* operates with external interface boards
* m18x1.5 screw mount

Specifications
Heater voltage* 4.35v dc +/- 0.1v dc (1.85a)
Stand by 2v dc (0.85a)
GOLD Member
Sep-12-19
 
Commodity:Sodium Aluminate
Other names:Aluminium sodium dioxide; SodiumaluminatecaHO; dialuminum; oxygen(-2) anion; sodiooxysodium
Molecular formula: NaAlO2
CAS No.: 1302-42-7

Property: colorless, odorless, tasteless, strongly alkaline.

Solid type: white powder or granules, hygroscopic, readily soluble in water. The aqueous solution may absorb CO2 and form aluminum hydroxide precipitate. Addition of NaOH is required to increase stability.

Liquid type: transparent slurry, stable during storage life. Prolonged stay of diluted aqueous solution may cause aluminum hydroxide precipitate.

Use:
In the construction process, it can be used as leaking stoppage agent combined with the sodium silicate.
In paper-making, this product can mix with aluminum sulfate to be a good filling agent.
In water treatment, it can be used as additive of purifier.

Technical specifications:
ModelNa2Al2O4Al2O3Na2O/Al2O3Insoluble % Density,
g/c m3Shelf life, month
LiquidA-129181.700.51.48±0.0112
A-238241.300.51.50±0.0112
SolidSNA162391.25±0.050.5 24
SNA265411.25±0.050.5 24
SNA377481.25±0.050.5 24
SNA480501.25±0.050.5 24

Packing: Solid powder in 25kg PP bag
Liquid in 300kg drums or 1500kg IBC tank
1675 O2S Fr T2 Zirconium Dioxide Oxygen Sensor Suppliers
Short on time? Let O2S Fr T2 Zirconium Dioxide Oxygen Sensor sellers contact you.
Feb-27-17

O2S-Fr-T5 Oxygen Sensors

$1
MOQ: Not Specified
Supplier From Shenzhen, Guangdong, China
 
Features
* oxygen pressure range 2 mbar - 3bar
* zirconium dioxide (zro2 ) sensing elements
* non-consumption technology
* integral heating element
* no need for temperature stabilisation
* no reference gas required
* high accuracy
* linear output signal
* operates with external interface boards

Specifications
Heater voltage:
Porous cap (15mm): 4.35v dc +/- 0.1v dc (1.85a)
Stand by: 2v dc (0.85a)
Pump resistance @ 700'C: < 6kOhm
Permissible gas temperature: -100 to 250C
Gas flow rate: 0 to 10 m/s
Repetitive permissible acceleration: 5 g
Incidental permissible acceleration: 30 g
GOLD Member
VERIFIED
Jul-12-24
Supplier From Mumbai, Maharashtra, India
May-10-17
Supplier From Shenzhen, Nanshan, China
 
FEATURES
* Oxygen pressure range 2 mbar - 3bar
* Zirconium dioxide (ZrO2 ) sensing elements
* Non-consumption technology
* Integral heating element
* No need for temperature stabilisation
* No reference gas required
* High accuracy
* Linear output signal
* Operates with external interface boards

SPECIFICATIONS
Heater Voltage
Porous Cap (15mm) 4.35V DC ± 0.1V DC (1.85A)
Stand by 2V DC (0.85A)
Pump resistance @ 700'C < 6kâ?¦
Permissible gas temperature -100 to 250'C
Gas flow rate 0 to 10 m/s
Repetitive permissible acceleration 5 g
Incidental permissible acceleration 30 g

z
GOLD Member
Nov-19-20

Copper Cathode 99.99%

$800
MOQ: Not Specified
Supplier From Saint-Paul, France
 
(LME standards) Standard Cu Cathode-1, purity 99, 97-99, 99 %Dimension: 914 mm x 914 mm x 12 mm (LME standards)

Copper (Cu) min% 99.99%
Other materials may be present which are described below:
Oxygen O2 --
Sulfur S 4 PPM
Iron Fe 2 PPM
Silver(Argent 10 PPM
Lead Pb 0.2 PPM
Nickel Ni 0.2 PPM
Selenium Se 0.3 PPM
Antimony Sb 0.1 PPM
Silica Si 0.3 PPM
Cobalt Co 0.2 PPM
Arsenic As 0.1 PPM
Bismuth Bi 0.1 PPM
Manganese Mn 0.1 PPM
Tellurium Te 0.05 PPM
Aluminum Al 0.5 PPM
Magnesium Mg 0.4 PPM
Zinc Zn 0.4 PPM
GOLD Member
Nov-19-20

Quality Copper Cathode Grade A

$800
MOQ: Not Specified
Supplier From Saint-Paul, France
 
(LME standards) Standard Cu Cathode-1, purity 99, 97-99, 99 %Dimension: 914 mm x 914 mm x 12 mm (LME standards)

Copper (Cu) min% 99.99%
Other materials may be present which are described below:
Oxygen O2 --
Sulfur S 4 PPM
Iron Fe 2 PPM
Silver(Argent 10 PPM
Lead Pb 0.2 PPM
Nickel Ni 0.2 PPM
Selenium Se 0.3 PPM
Antimony Sb 0.1 PPM
Silica Si 0.3 PPM
Cobalt Co 0.2 PPM
Arsenic As 0.1 PPM
Bismuth Bi 0.1 PPM
Manganese Mn 0.1 PPM
Tellurium Te 0.05 PPM
Aluminum Al 0.5 PPM
Magnesium Mg 0.4 PPM
Zinc Zn 0.4 PPM
Dec-02-16
Supplier From Shenzhen, Guangdong, China
 
Features
* oxygen pressure range 2 mbar - 3bar
* zirconium dioxide (zro2 ) sensing elements
* non-consumption technology
* integral heating element
* no need for temperature stabilisation
* no reference gas required
* high accuracy
* linear output signal
* operates with external interface boards
* pcb mountable

Specifications
Heater supply*
Porous lid cap 4vdc +/- 0.1vdc (1.7a)
Stand by 1.65vdc (0.7a)
Full porous cap 4.35v dc +/- 0.1v dc (1.85a)
Stand by 2v dc (0.85a)
GOLD Member
Mar-16-23

General Titanium Dioxide Cr6618

$500
MOQ: 100  Metric Tonnes
Sample Available
Supplier From Johannesburg, Gauteng, South Africa
 
GENERAL TITANIUM DIOXIDE CR6618
CR6618 is a zirconium, aluminum and organic surface treated multipurpose rutile titanium dioxide pigment, it has average particle
size distribution, good whiteness, good dispersion, high gloss, good hiding power and high weather resistance properties. lt is
widely used in coating, paints, ink, leather, rubber and ink production.

Application Fields
Coating/Ink (solvent-based, tin-printing) /Leather, color paste and sheet/Paints /Plastic/Rubber
GOLD Member
VERIFIED
Jun-20-22

Antioxidants Silicon Dioxide

$7.35
MOQ: 1000  Kilograms
Sample Available
 
Silicon Dioxide, E551, CAS no.7631-86-9, white powder. Silicon dioxide (SiO2), also known as silica, is a natural compound made of two of the earth's most abundant materials: silicon (Si) and oxygen (O2). Silicon Dioxide is a common additive in the production of foods, where it is used primarily as a flow agent in powdered foods, or to absorb water in hygroscopic applications used in silica gel, control moisture levels to avoid prevent certain goods from going bad. It is often used in cheese, fat spreads, confectionery, dried vegetables, etc.

As an experienced Silicon Dioxide manufacturer and supplier, we has been supplying and exporting Silicon Dioxide for almost 10 years, please be assured to buy from us. Any inquiries about price and the market trend please feel free to contact us, we will reply you within 1 working day.

Silicon Dioxide Specification
Item Standard
Appearance White powder
Purity (SiO2, %) 96
Oil absorption (cm3/g) 2.0~ 3.0
Loss on drying (%) 4.0~ 8.0
Loss on ignition (%) 8.5
BET (m2/g) 170~ 240
pH (10% solution) 5.0~ 8.0
Sodium sulfate (as Na2SO4, %) 1.0
Arsenic (As) 3mg/kg
Lead (Pb) 5 mg/kg
Cadium (Cd) 1 mg/kg
Mercury (Hg) 1 mg/kg
Total heavy metals (as Pb) 20 mg/kg
Total plate count 500cfu/g
Salmonella spp./ 10g Negative
Escherichia coli/ 5g Negative
GOLD Member
Mar-02-23

Sodium Chlorate

$900
MOQ: 25  Tons (US)
Sample Available
Supplier From Sharjah, Sharjah, United Arab Emirates
 
Sodium chlorate is an inorganic compound with the chemical formula NaClO3. It is a white crystalline powder that is readily soluble in water. It is hygroscopic. It decomposes above 300 C to release oxygen and leaves sodium chloride. Several hundred million tons are produced annually, mainly for applications in bleaching pulp to produce high brightness paper.

The main commercial use for sodium chlorate is for making chlorine dioxide (ClO2). The largest application of ClO2, which accounts for about 95% of the use of chlorate, is in bleaching of pulp. All other, less important chlorates are derived from sodium chlorate, usually by salt metathesis with the corresponding chloride. All perchlorate compounds are produced industrially by the oxidation of solutions of sodium chlorate by electrolysis.
Jun-23-17
Supplier From Shenzhen, Nanshan, China
 
Zirconia o2 sensors
Miniature series

The miniature zirconium dioxide oxygen sensors can be pcb mounted and are used when measuring ambient gas with the complete sensor immersed in the atmosphere which is to be measured.

Features
* zirconium dioxide (zro2 ) sensing elements
* long life, non-depleting technology
* integral heating element
* high accuracy
* requires an external interface board to operate

Benefits
* no reference gas required
* no need for temperature stabilisation
* pcb mountable

Technical specifications
Heater voltage
Standard response sensor: 4v dc â± 0.1v dc (1.7a)
Standby: 1.65v dc (0.7a)
Fast response sensor: 4.35v dc â± 0.1v dc (1.85a)
Standby: 2v dc (0.85a)
Pump impedance at 700'c: < 6k
Permissible gas temperature: -100'c to +250'c
Gas flow rate : 0 - 10 m/s
Repetitive permissible acceleration: 5g
Incidental permissible acceleration: 30g

Output values
Oxygen pressure range: 2mbar - 3bar max
Accuracy: 5mbar max
Internal operational temperature: 700'c
Response time (10 - 90% step)
Standard response sensor:
Mar-26-04
 
Thank you for purchasing and using our company's ultrasonic oxygen concentration / flow sensor.

1, please carefully read the instructions and fully understand the contents of the sensor after operation and maintenance. Improper use may cause damage to the sensor. (no violent impact and falling ground)
2, without the consent of the company, it is strictly prohibited to alter the structure and components of the sensor without authorization. The company is not responsible for any personal safety incidents or sensor abnormalities caused by unauthorized alterations.
3, the specifications and instruction contents of this sensor may be changed due to the technical improvement of the product.
4, this instruction manual must be handed to the actual user of the sensor and stored in it, and placed at any time where the actual user of the sensor can access it.
5, the company has the right to interpret the instructions for the sensor.

2ã??technical parameter
Measurement parameters measuring method range Resolution accuracy

O2 Ultrasonic 20.5%-95.6% 0.1% �±1.8%FS 5-45â??
Note: the range can be customized according to customer requirements.

Sample gas requirements Water removal (no condensation); dust filtration (
Dec-01-17
Supplier From Shenzhen, Guangdong, China
 
O2-M2 Oxygen Sensor Description
Alphasense Oxygen sensors use capillary flow control.

Unlike partial pressure oxygen sensors, they have good pressure and temperature dependence, making them the best choice in safety applications.

Standard galavanic sensors use lead for greatest reliability but fixed lifetime.

Specifications
* Output: 80 to 120 uA @ 20.9% O2
* Response time t90: < 15 (s) from 20.9% to 0% O2


* Linearity: 0.6 % O2 deviation @ 10% O2
* Operating life: > 24 months
*Temperature range: -30 to 55 'C
* Pressure range: 80 to 120 kPa
* Humidity range: 5 to 95 % rh continuous
* Diameter: 20.0 mm (including label)
* Heigh: 17.4 mm (including foam ring)
* Weight: < 16g
GOLD Member
May-11-21
 
We Specializes In Supply Medical equipment such as : Oxygen Concentractor 10L , Made in USA.
Features:
-User-preferred neutral color to help blend in to any home environment.
-Invacare SensO2 Oxygen Purity Sensor to warn you if purity drops.
-Compatible with the Invacare HomeFill Oxygen System.
-Battery-free power loss alarm for added peace of mind.
-Three separate filters assure oxygen purity.
Dimension:
26-3/8" (H) x 18-3/8" (W) x 14-3/8" (D).
Product Weight: 53 lb.
Shipping Product Weight: 63lb.
Oxygen: Oxygen Flow: 10 LPM
Oxygen Purity - 87%-95.6% At all flow rates.
Flow Settings: Flow Range: 2-10 LPM
MQO: 100 PCS
Certificate : CE, FDA, 510K
Made in USA
GOLD Member
Jan-20-23
Supplier From Dhaka, Dhaka, Bangladesh
 
Honeywell BW Solo is a easy to service single-gas detector with BLE connectivity that provides real-time visibility into the status and safety of hazardous-area workers, helping companies respond faster, more knowingly and decisively to safety incidents. The first single-gas detector with the 1 Series sensor for CO, H2S and O2

Features & Benefits:
User-friendly operation,
Easy-to-read display for multiple languages,
Lightweight convenience,
Ease of maintenance,
Serviceability,
The new 1-Series sensor for enhanced reliability,
Connected Bluetooth Low Energy (BLE) capabilities.
GOLD Member
Dec-10-22

Urea 46% Agricultural Urea, Vehicle Urea

$488
MOQ: 40  Tons (US)
Sample Available
Supplier From Chongqing, Yuzhong District, China
 
Agricultural urea N46 46%


Properties of urea
Urea, also known as carbamide, carbamide and urea. Pure urea is white, tasteless, odorless, needle shaped or prismatic crystal, with a melting point of 132.7 â?? under normal pressure. It is hygroscopic, deliquescent, hydrolyzable, and weakly alkaline. It is made into compound fertilizer with acid fertilizer. Urea is an organic compound composed of carbon, nitrogen, oxygen and hydrogen. It is a white crystal. Urea is one of the simplest organic compounds. The most important use of urea is as fertilizer. Its nitrogen content is more than 46%. After being converted into ammonium carbonate in soil, urea is hydrolyzed and absorbed by plants. It is the nitrogen fertilizer with the highest nitrogen content at present.
Molecular formula of urea: CO (NH2) 2, molecular weight 60.06, density 1.335g/cm �³ï¼? The melting point is 132.7 â??. Soluble in water and alcohol, insoluble in ether and chloroform. It is slightly alkaline. It can react with acid to form salt. It has hydrolysis. Condensation reaction can be carried out at high temperature to produce biuret, triuret and cyanuric acid. Heat to 160 â?? and decompose to generate ammonia gas and turn into cyanic acid at the same time. Urea can be hydrolyzed into ammonia and carbon dioxide under the action of acid, alkali and enzyme (acid and alkali need to be heated). Unstable to heat, heat to 150 â??ï½? 160 â?? to deamination to biuret. Urea is easily soluble in water, 105g can be dissolved in 100ml water at 20 â??, and the aqueous solution shows neutral reaction. There are two kinds of urea products: crystalline urea is white acicular or prismatic crystal with strong hygroscopicity; Granular urea is a translucent particle with a particle size of 1~2mm, which has a smooth appearance and improved moisture absorption.
Urea is a physiologically neutral fertilizer, which does not leave any harmful substances in the soil and has no adverse effects after long-term application. However, a small amount of biuret, also known as biuret, will be produced when the temperature is too high during granulation, which has an inhibitory effect on crops. Urea is molecular before conversion and cannot be adsorbed by soil, so it should be prevented from being lost with water; The ammonia formed after conversion is also volatile, so urea should also be deeply covered with soil. Urea is the first synthetic organic substance and widely exists in nature, such as 0.4% urea in fresh human feces.
The new version of national standard GB/T2440-2017 for urea has been officially implemented since July 1, 2018. Compared with the replaced 2001 standard, certain adjustments have been made.
New standard GB/T2440-2017
1675 O2S Fr T2 Zirconium Dioxide Oxygen Sensor Suppliers
Short on time? Let O2S Fr T2 Zirconium Dioxide Oxygen Sensor sellers contact you.
Explore O2S Fr T2 Zirconium Dioxide Oxygen Sensor related import export discussions