Find Verified Inv Time 3O C Or 2O C 1E Ft Relay Ac Se Suppliers, Manufacturers and Wholesalers

VERIFIED
Jun-19-21
 
GBCDG31EG8101KCH
INV TIME 3O/C OR 2O/C &1E/FT RELAY AC SE
Model No : CDG31EG8101K(M)
CDG31S/T
APPLICATION - 3 O/C
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C OR O/V SETTING - 2.5 -10 Amps.
Name Plate RFG9126 774
Outline Diagram MFJ014
Wiring Diagram MADZ821-17
VERIFIED
Jun-19-21
 
GBCDG31EG8101LCH
INV TIME 3O/C OR 2O/C &1E/FT RELAY AC SE
Model No - CDG31EG8101L(M)
RELAY TYPE - CDG31S/T
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F SETTING - 1 - 4 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
Name Plate - RFG9126 904
Outline Diagram MFJ014
Wiring Diagram MADZ821-17
VERIFIED
Jun-19-21
 
ALSTOM GBCDG31EG8102LCH
INV TIME 3O/C OR 2O/C &1E/FT RELAY AC SE
Model No : - CDG31EG8102L(M)
RELAY TYPE - CDG31S/T
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F SETTING - 0.5 - 2 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
Name Plate - RFG9126 903
Outline Diagram MFJ014
Wiring Diagram MADZ821-17
VERIFIED
Jun-19-21
 
ALSTOM GBCDG31EG8106LCH
INV TIME 3O/C OR 2O/C &1E/FT RELAY AC SE
Relay model no CDG31EG8106LCH
Relay type CDG31
Case Size 3D Hor
Application 2 O/C & 1 E/F
C.T.Secondary 5 Amps
Current Setting - O/C 2.5 TO 10 Amps
Current Setting - E/F 1 TO 4 Amps
Contacts 2 N/O 2 N/C H/R
Output Contacts 2 N/O 2 N/C H/R
Taps STD
Burden / Operating Time 3 Va / 3 Secs.
Frequency 50 Hz
Name Plate RFG9126 904
Outline Drawing MFJ 014
Wiring Diagram MADZ821.42
VERIFIED
Jun-19-21
 
ALSTOM GBCDG31EG8111KCH
INV TIME 3O/C OR 2O/C &1E/FT RELAY AC SE
RELAY MODEL CDG31EG8111KCH
APPLICATION 3 O/C
BURDEN / D.M.T 3 VA / 1.3 SEC.
C.T. SECONDARY 5 AMP C.T.
CASE SIZE 3D HORZ.
CONTACTS (S/R OR H/R) 2 N/O 2 N/C H/R
FLAG YES
FREQUENCY 50 HZ
MOUNTING FLUSH
O/C SETTING 2.5 - 10 Amps.
NAME PLATE-1 RFG9125 774
OUTLINE DRAWING MFJ014
WIRING DIAGRAM MADZ821-17
978 Inv Time 3O C Or 2O C 1E Ft Relay Ac Se Suppliers
Short on time? Let Inv Time 3O C Or 2O C 1E Ft Relay Ac Se sellers contact you.
VERIFIED
Jun-19-21
 
ALSTOM GBCDG31EG8111LCH
INV TIME 3O/C OR 2O/C &1E/FT RELAY AC SE
TECHNICAL SPECIFIFICATION
Model No : CDG31EG8111LCH
CDG31S/T
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 1.3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F SETTING - 1 - 4 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps
Name Plate - RFG9125 904
Outline Diagram MFJ014
Wiring Diagram MADZ821-17
VERIFIED
Jun-19-21
 
ALSTOM GBCDG31EG8112LCH
INV TIME 3O/C OR 2O/C &1E/FT RELAY AC SE
TECHNICAL SPECIFICATION
Model No : - CDG31EG8112LCH
RELAY TYPE - CDG31 AC S/T
APPLICATION - 2 O/C + 1 E/F
C.T. SECONDARY - 5 AMP C.T.
O/C SETTING - 2.5 - 10 Amps.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F SETTING - 0.5 - 2 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
BURDEN / D.M.T - 3 VA / 1.3 SEC.
TAPS - STD
Name Plate - RFG9125 903
Outline Diagram MFJ014
Wiring Diagram MADZ821-17
VERIFIED
Jun-19-21
 
ALSTOM GBCDG31EG8114LCH
INV TIME 3O/C OR 2O/C &1E/FT RELAY AC SE
TECHNICAL SPECIFIFICATION
Model No : CDG31EG8114LCH
CDG31 Ac Series Trip
Application - 2 O/C + 1 E/F
Case Size - 3D Horz
C.T. Secondary - 1 Amp
Burden / D.M.T - 3 Va / 1.3 Sec
O/C Setting - 0.5 - 2 Amps
Tap - Std.
E/F Setting - 0.1 - 0.4 Amps
Contacts - 2 N/O 2 N/C H/R
Flag - Yes
Frequency - 50 Hz
Mounting - Flush
Name Plate - RFG9125 901
Outline Diagram MFJ014
Wiring Diagram MADZ821-17
GOLD Member
Jul-31-20

Mung Bean Peeled

$2.50 - $5
MOQ: 50  
Sample Available
 
Moisture : 8.5% max.
Impurities : 1% max.
Size (kernels/100 gr):
o 180-200/
o 200-220/
o 220-240/
Broken beans: 3% max.
Crop: newest, Origin: Vietnam.
Packed in 25/50 kg PP Bag or Jute Bag. 18 MT/ 20'ft.
Price: please contact for updated price.
Payment & delivery: L/C at sight or T/T 30% in advance. Lead time: 2 weeks/ 1*20'FCL.
VERIFIED
Jun-18-21
 
GBCDG31EG001SACH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No : CDG31EG001SA(M)
CDG31
APPLICATION - 3 O/C
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O S/R
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
Name Plate RFG9126774
Outline Diagram MFJ014
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-18-21
 
GBCDG31EG001SBCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Technical Specifications
Model No - CDG31EG001SBCH
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 3 SECS.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F SETTING - 1 - 4 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
NAME PLATE - RFG9126 904
Outline Diagram MFJ 014
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-18-21
 
GBCDG31EG001SCCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No : CDG31EG001SC(M)
CDG31
APPLICATION - 3 O/C
BURDEN / D.M.T - 3 VA /3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
Name Plate RFG9126674
Outline Diagram MFJ014
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-18-21
 
GBCDG31EG001SDCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31EG001SD(M)
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F SETTING - 1 - 4 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
Name Plate - RFG9126 904
Outline Diagram MFJ 014
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-18-21
 
GBCDG31EG002SACH
NON DIR.SELF POWER 3 O/C RELAY 2M S/R
TECHNICAL SPECIFICATION
Model No : CDG31EG002SACH
CDG31
APPLICATION - 3 O/C
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O S/R
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C OR O/V SETTING - 0.5 - 2 Amps.
Name Plate RFG9126771
Outline Diagram MFJ014
Wiring Diagram MADZ802-63-1
VERIFIED
Jun-18-21
 
GBCDG31EG002SBCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
MODEL NO - CDG31EG002SBCH
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F SETTING - 0.5 - 2 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
NAME PLATE - RFG9126 903
Outline Diagram MFJ 014
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-18-21
 
GBCDG31EG002SCCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Technical specification
Relay Model No CDG31EG002SC(M)
Relay type CDG31
CASE SIZE 3D HORZ.
APPLICATION 3 O/C
O/C SETTING 0.5 - 2 Amps
BURDEN / D.M.T 3 VA / 3 SEC.
Taps Std
C.T. SECONDARY 1 AMP CT.
CONTACTS (S/R OR H/R) 2 N/O 2 N/C H/R
FLAG YES
FREQUENCY 50 HZ
MOUNTING FLUSH
Name Plate RFG9126 671
Outline Diagram MFJ 014
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-18-21
 
GBCDG31EG002SDCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Technical Specifications
Relay model No CDG31EG002SDCH
Relay type CDG 31
Case size 3D H 30T
Application 2 O/C + 1 E/F
Current setting - O/C 2.5 to 10 amps
( 50-200% )
Contacts (S/R OR H/R) 2 N/O 2 N/C H/R
Output Contacts 2 N/O 2 N/C H/R
Taps / Burden Std / 3 VA
C.T.Secondary 5 amps
D.M.T 3 secs
Current setting - E/F 0.5 to 2 amps
(10 - 40% )
Flag / Mounting Yes / Flush
Frequency 50 Hz
Name plate RFG9126 903
Outline Diagram MFJ 014
Wiring Diagram MADZ 802.64-1
VERIFIED
Jun-18-21
 
GBCDG31EG003SACH
NON DIR.SELF POWER 3 O/C RELAY 2M S/R
Technical specification
Relay Model No CDG31EG003SACH
Relay type CDG 31
Case size 3D Hor.
Application 3 O/C
Current setting 0.2 to 0.8 amps
Contacts (S/R OR H/R) 3 N/O S/R
Output contacts 2 N/O S/R
Burden / Operating Time 3 VA / 3 Secs.
C.T.Secondary 1 amps
Taps / frequency Std / 50 Hz.
Note:-write in name plate as
over current instead of E/F.
And Erase E/F symbol.
Flag Yes
Mounting Flush
Name Plate RFG9126 793
Outline Diagram MFJ 014
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-18-21
 
GBCDG31EG003SBCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31EG003SB(M)
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F SETTING - 0.2 - 0.8 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 0.5 - 2 Amps.
NAME PLATE - RFG9126 902
Outline Diagram MFJ014
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-18-21
 
GBCDG31EG003SDCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31EG003SD(M)
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F SETTING - 0.2 - 0.8 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 0.5 - 2 Amps.
Name Plate - RFG9126 902
Outline Diagram MFJ 014
Wiring Diagram MADZ802.64-1