Vacuum Circuit Breaker HVD7 40.5KV 1250A outdoor HV AC VCB from Hubei JUCRO Electric
1. Introduction
HVD7 40.5KV 1250A outdoor HV AC vacuum circuit breaker VCB has many visual advantages like reasonable design, fashionable appearance, high safety and reliability, simple maintenance, long electric life. It is the ideal upgraded products of 35KV outdoor oil circuit breakers.
HVD7-40.5 1250A vacuum circuit breaker is applicable for three-phase power system of AC 50HZ.It is used to make and break the load current ,overload current and short-circuit current.
2. Applicable environment
2.1The ambient temperature should be -30degree~ +40degree(-40degree in the frosty area);
2.2Altitude should not exceed 2000m(over 2000m is plateau type);
2.3The wind pressure should not exceed 700Pa(equal to wind speed 34m/s);
2.4Air pollution degree: 3,that of antifouling type:4;
2.5The installation site should be free from the fire, explosion, chemical corrosion and serious vibration.
Model No.: TD 12kv 1250A 25KA (JUC613) vacuum interrupter for VCB
Main technical parameters
Rated voltage: 12 KV
Rated current: 1250A
Rated power frequency withstand voltage: 42 KV
Rated lightning impulse withstand voltage: 75 KV
Rated short circuit breaking current: 25KA
Rated short circuit making current(peak value): 63KA
Breaking operations under rated short circuit breaking current: 30 times
Rated short time withstand current: 25KA
Rated withstand current(peak value): 63KA
Rated duration of short circuit: 4S
Mechanical life: 20,000 times
Closing force due to bellows and atmosphere: 120±50N
Force required to hold contacts opening at full stroke: 190±50N
Circuit resistance at lowest rated contacts force
Storage life: 20 years
Limiting abrasion of contacts: 3 mm
Mechanical requiements of vacuum circuit breaker
Clearance between opening contacts: 11±1mm
Average opening speed(Contacts closing position~75% contacts opening distance): 1.1±0.2 m/s
Average closing speed(30% contacts opening distance~contacts closing position): 0.6±0.2 m/s
Rated contacts pressure: 2000±200N
Contacts bouncing duration at closing operation: â?¤2ms
Contacts re-bouncing clearance at opening operation: â?¤2mm
Synchronism of three phases: â?¤1ms
Model No.: TD 12kv 1250A 25KA (JUC613) vacuum interrupter for VCB
Main technical parameters
Rated voltage: 12 KV
Rated current: 1250A
Rated power frequency withstand voltage: 42 KV
Rated lightning impulse withstand voltage: 75 KV
Rated short circuit breaking current: 25KA
Rated short circuit making current(peak value): 63KA
Breaking operations under rated short circuit breaking current: 30 times
Rated short time withstand current: 25KA
Rated withstand current(peak value): 63KA
Rated duration of short circuit: 4S
Mechanical life: 20,000 times
Closing force due to bellows and atmosphere: 120±50N
Force required to hold contacts opening at full stroke: 190±50N
Circuit resistance at lowest rated contacts force: =20µO
Storage life: 20 years
Limiting abrasion of contacts: 3 mm
Mechanical requiements of vacuum circuit breaker
Clearance between opening contacts: 11±1mm
Average opening speed(Contacts closing position~75% contacts opening distance): 1.1±0.2 m/s
Average closing speed(30% contacts opening distance~contacts closing position): 0.6±0.2 m/s
Rated contacts pressure: 2000±200N
Contacts bouncing duration at closing operation: =2ms
Contacts re-bouncing clearance at opening operation: =2mm
Synchronism of three phases: =1ms
Model No.: TD 12kv 1250A 31.5KA (JUC618) vacuum interrupter for VCB
Main technical parameters
Rated voltage: 12 KV
Rated current: 1250A
Rated power frequency withstand voltage: 42 KV
Rated lightning impulse withstand voltage: 75 KV
Rated short circuit breaking current: 31.5KA
Rated short circuit making current(peak value): 80KA
Breaking operations under rated short circuit breaking current: 30 times
Rated short time withstand current: 31.5KA
Rated withstand current(peak value): 80KA
Rated duration of short circuit: 4S
Mechanical life: 20,000 times
Closing force due to bellows and atmosphere: 120±50N
Force required to hold contacts opening at full stroke: 190±50N
Circuit resistance at lowest rated contacts force: =20µO
Storage life: 20 years
Limiting abrasion of contacts: 3 mm
Mechanical requiements of vacuum circuit breaker
Clearance between opening contacts: 11±1 mm
Average opening speed(Contacts closing position~75% contacts opening distance): 1.1±0.2 m/s
Average closing speed(30% contacts opening distance~contacts closing position): 0.6±0.2 m/s
Rated contacts pressure: 3150±200 N
Contacts bouncing duration at closing operation: =2 ms
Contacts re-bouncing clearance at opening operation: =2 mm
Synchronism of three phases: =1 ms
Model No.: TD 12kv 1250A 31.5KA (JUC619A) vacuum interrupter for VCB
Main technical parameters
Rated voltage: 12 KV
Rated current: 1250A
Rated power frequency withstand voltage: 48 KV
Rated lightning impulse withstand voltage: 85 KV
Rated short circuit breaking current: 31.5KA
Rated short circuit making current(peak value): 80KA
Breaking operations under rated short circuit breaking current: 30 times
Rated short time withstand current: 31.5KA
Rated withstand current(peak value): 80KA
Rated duration of short circuit: 4 s
Mechanical life: 10,000 times
Closing force due to bellows and atmosphere: 120±50 N
Force required to hold contacts opening at full stroke: 190±50 N
Circuit resistance at lowest rated contacts force: =20µO
Storage life: 20 years
Limiting abrasion of contacts: 3 mm
Mechanical requiements of vacuum circuit breaker
Clearance between opening contacts: 11±1 mm
Average opening speed(Contacts closing position~75% contacts opening distance): 1.1±0.2 m/s
Average closing speed(30% contacts opening distance~contacts closing position): 0.6±0.2 m/s
Rated contacts pressure: 3150±200 N
Contacts bouncing duration at closing operation: =2 ms
Contacts re-bouncing clearance at opening operation: =2 mm
Synchronism of three phases: =1 ms
* It Needs additional insultating protection.
39 Hvd7 40 5Kv 1250A Vcb Suppliers
Short on time? Let Hvd7 40 5Kv 1250A Vcb sellers contact you.
. Introduction
HVD7 40.5KV 1600A outdoor HV AC vacuum circuit breaker VCB has many visual advantages like reasonable design, fashionable appearance, high safety and reliability, simple maintenance, long electric life. It is the ideal upgraded products of 35KV outdoor oil circuit breakers.
HVD7-40.5 1600A vacuum circuit breaker is applicable for three-phase power system of AC 50HZ.It is used to make and break the load current ,overload current and short-circuit current.
2. Applicable environment
3.1The ambient temperature should be -30degree~ +40degree(-40degree in the frosty area);
3.2Altitude should not exceed 2000m(over 2000m is plateau type);
3.3The wind pressure should not exceed 700Pa(equal to wind speed 34m/s);
3.4Air pollution degree: 3,that of antifouling type:4;
3.5The installation site should be free from the fire, explosion, chemical corrosion and serious vibration.
1. Main technical parameters
Rated voltage: 33kv 36KV
1 minute power frequency withstand voltage, dry test: 95 kv
1 minute power frequency withstand voltage, wet test: 80 kv
Lightning impulse withstand voltage(peak value): 185 kv
Rated current: 1600A / 2000A
Rated short-circuit breaking current: 20KA, 25KA, 31.5KA
Rated short-circuit making current(peak): 50KA, 63KA, 80KA
Rated operating sequence: O-0.3s-CO-180s-CO
Rated short-time withstand current: 20KA, 25KA, 31.5KA
Rated peak withstand current: 50KA, 63KA, 80KA
Rated short-circuit duration: 4 s
Rated control voltage: AC220,110;DC220,110
Rated short-circuit breaking current break times: 20 times
Full-break time:
Vacuum Circuit Breaker HVD1-12KV 1250A 25KA VCB with copper parts 210mm phase distance
HVD1-12(VS1-12) type indoor AC HV vacuum circuit breaker (hereinafter referred to as circuit breaker) are suitable for 12kV air-insulated indoor switchgears, used as protection and control unit of power equipment of industrial& mining enterprise. Due to the super excellence, it is especially for location where requires the frequent operation of rated working current or multi breaking short circuit current.
The circuit breaker adopts the integrated design of operating mechanism and circuit breaker body, servers as not only fixed installation, but also the handcart unit through equipping with a special propelling mechanism.
2. Service conditions
3.1 Environment temperature:-15®C~+40®C;
3.2 Environment humidity: Daily average relative humidity:95%, monthly average relative humidity:90%; Daily average saturated vapor pressure:2.210-3Mpa,monthly average saturated vapor pressure:1.810-3Mpa;
3.3 Altitude: Not exceed 1000m;
3.4 Earthquake intensity: Not exceed°ree;
3.5 Service location: No water, flammable or explosive matter, chemical corrosive gas or drastic vibration.
1.Main specifications and technical parameters
Rated voltage: 12 kv
Rated lightning impulse withstand voltage(1min): 75 kv
Rated short-time power frequency withstand voltage (1min): 42 kv
Rated short-circuit breaking current: 25KA
Rated current: 1250A
Rated peak withstand current: 63KA
Rated shorted-time withstand current: 25KA
Rated shorted-time making current(peak): 63KA
Power frequency withstand voltage of secondary circuit(1min): 2000 v
Opening time(rated voltage): 20~50 ms
Closing time(rated voltage): 30~70 ms
Rated short-circuit current breaking times: 50(40kA 30) times
Mechanical life: 30,000 times
1. Introduction
HVD7 33KV 36kv outdoor HV AC vacuum circuit breaker VCB has many visual advantages like reasonable design, fashionable appearance, high safety and reliability, simple maintenance, long electric life. It is the ideal upgraded products of 35KV outdoor oil circuit breakers.
HVD7-40.5 vacuum circuit breaker is applicable for three-phase power system of AC 50HZ.It is used to make and break the load current ,overload current and short-circuit current.
2. Applicable environment
3.1The ambient temperature should be -30degree~ +40degree(-40degree in the frosty area);
3.2Altitude should not exceed 2000m(over 2000m is plateau type);
3.3The wind pressure should not exceed 700Pa(equal to wind speed 34m/s);
3.4Air pollution degree: 3,that of antifouling type:4;
3.5The installation site should be free from the fire, explosion, chemical corrosion and serious vibration.
1. Main technical parameters
Rated voltage: 33kv 36KV
1 minute power frequency withstand voltage, dry test: 95 kv
1 minute power frequency withstand voltage, wet test: 80 kv
Lightning impulse withstand voltage(peak value): 185 kv
Rated current: 1600A / 2000A
Rated short-circuit breaking current: 20KA, 25KA, 31.5KA
Rated short-circuit making current(peak): 50KA, 63KA, 80KA
Rated operating sequence: O-0.3s-CO-180s-CO
Rated short-time withstand current: 20KA, 25KA, 31.5KA
Rated peak withstand current: 50KA, 63KA, 80KA
Rated short-circuit duration: 4 s
Rated control voltage: AC220,110;DC220,110
Rated short-circuit breaking current break times: 20 times
Full-break time:
Vcb best quality having topmost brands available here
Brands : Siemens, Abb, Schnieder, Havells, Kirloskar, BCH, Bharat Bijlee etc
Out door and Indoor
Type Of Breaker: Vcb
Rated Bus Bar Current: 630, 1250A / 630, 1250, 1600, 2000, 4000A
Rated Voltage: 11Kv /12kv/33kv/ 36Kv
Short Time Withstands Current: 16Ka, 26.3Ka / 25Ka-40Ka
VIBRATION CONTROLLER WITH SENSOR HZD-W/L
Deyang Dongfang Yoyik is a trade production company with many international brands. Our source is authentic, product is quality guaranteed, price is reasonable, welcomed by our new and old customers. We also sell all kinds of processing parts, non-standard parts for power plant dedicated.
#DF-VIBRATION CONTROLLER WITH SENSOR HZD-W/L-DF
Pressure Switch 52RN-KK116-M1-C2A-XX618
Proximity Sensor 330180-X1 05
types of lvdt DET600A
Bolt electric heating rod ZJ-17.5-450
Level switch BH-026006-026
Steam Turbine Speed Probe CS-1-G-075-05-01
Cable grips XY2CZ524
ANTIPUMPING DEVICE ZN63(V1)-12KV VCB OF 1250A
EXTENSION CABLE 84508-17
High-temperature cable HSDS-40/L
differential pressure indicator HS75670
Eddy Current Signal Converter CON041/912-015
Location indicator ZDET250B
speed sensor QBJ-CS-1 L=75
TEXT DISPLAYER FD101
Power module DPC300D2BX-B01B
CLOSING/TRIP COIL ZN63(VS1)-12KV-1250A, 160 Ohm
Pressure Switch B424B XJLNH06
POWER FACTOR TRANSDUCER FPPF-V1-A2-F1-P2-06-D1
Eddy Current Sensor PR6424/001-121
HP expansion amplifier WT0120-A00-B00-C07-D90
Oxygen meter single heater HIGA2121
Eddy Current Sensor PR6422/001-000
Pressure switch DPSN4KB25XFSP5
RELY ELEC JR36-20
pressure sensor alarm 4NN-EE4-N4-C1A-X373
Two position,four-way solenoid valve YDK24DHS
LVDT transmitter XCBSQ-02/50-01-11
Sensor �?o nhi�t �?� b�n dầu thủy lực TEP11X321809
Eddy Current Sensor PR6423/004-100
Eddy Current Sensor PR6423/003-121
Sensor holder TDZ-A
lvdt measurement systems TDZ-1-50
speed sensor 143.35.19-1
SPEED MONITOR UNIT DM-11B
Eddy Current Sensor PR6422/002-111
VIBRATION CONTROLLER WITH SENSOR HZD-W/L
Dermal vesicle NXQA-40/20-L-EH
Deyang YOYIK have power plant professional accessories, non-standard pieces, to spare parts for processing. Only need to figure the number of other companies need drawings and drawings number. If you have any questions or concerns, please contact us. YOYIK has a good talent pool, the company is developing, you need to support, in order to witness its growth.
Yoyik can offer many spare parts for power plants as below:
#DF-Dermal vesicle NXQA-40/20-L-EH-DF
proximity sensor speed measurement TM0180-A07-B00-C04-D05
Eddy Current Sensor PR6422/002-101
LVDT transmitter XCBSQ-02/400-02-22
ANTIPUMPING DEVICE ZN63(V1)-12KV VCB OF 1250A
fluid level gauge UHZ-519C, Length: 5600mm
LVDT Sensor TD-1G-500-15
thermocouple 156.08.33.06(1)
Sensor Proximity Turbine CWY-DO-20Y-45K
TRANSMITTER AMPLIFIER GAP SEAL APH GJCT-15
Bolt electric heating rod ZJ-20-45(R)
Potential Transformer ZDC-2/11
Proximitor WTO112-A90-B00-C01
oil temperature sensor 04524-02230
Indicator light XB4BVM1
outlet Oil Temp., Monitoring Controller DC1040CR-702-100-E
nut and bolt induction heater RJ-17.5-450
DC AUXILIARY RELAY JT3-30/5
Stainless manometer YJTF-100
high pressure transducer RC778NZ084Z
Thyristor element 5STP1842L0013
Bolt electric heating rod ZJ-20-18
LVDT Sensor B151.36.09.G17
LVDT FOR HP Governing Valves ZDET-100A
sight glass level transmitter FMU230E-AA32
LVDT Sensor TH-3G-100-15-01
6KV MOTOR PROTECTION RELAY NEP 998B
MONITOR, VIBRATION HY-3SF
magnetostrictive displacement transducer TD-1 940MM
TSI overspeed probe DSF1210
Rotation Speed Sensor DF6202
actuator position sensor HTD-250-3
RELAY AUXILIARY RELAY JZS-7/2403
System Power card MBD 205
Current Sensor TM0180-A07-B00-C05-D10
Bolt electric heating rod ZJ-20-47
Turbine bolt electric heating rod ZJ-20-T19
Dermal vesicle NXQA-40/20-L-EH
1. Introduction
KYN28-12 indoor metalclad withdrawable switchgear is designed to be complete distribution equipment with three-phase A.C. singe busbar and single busbar section system having a rated voltage of 3.6~12kV and rated frequency of 50Hz.The switchgear is mainly employed in receiving and distribution of power energy from the network as well as starting of large-sized HV motors. In addition, the switchgear is provided with controlling, protection and monitoring functions. The switchgear conforms to IEC 298, GB 3906, DL/T404-91 and other standards. The switchgear itself owns five prevention functions such as prevention of misoperation of circuit breakers, prevention of pushing or pulling truck with load, prevention of closing earth switch under voltage, prevention of supplying power when earth switch is at the earth position and prevention of entering the electrical separation zone by accident. The switchgear selects not only VS1 vacuum circuit breakers but also ABB made VD4 vacuum circuit breaders, thus recogninzed as power distribution equipment with excellent performance.
2. Working condition
2.1 altitude: 1000m
2.2 temperature: -10celsius degree ~+40celsius degree
2.3 relative humidity: daily average value 95%, monthly average value 90%
2.4 saturated vapor pressure: daily average value 2.2 10-3MPa, monthly average value 1.8 10-3MPa
2.5 earthquake intensity: less than 8 degree
2.6 protect the product from fire, explosion, earthquake and corrosion atmosphere.
3. Main features:
3.1. the enclosure is completely adopts the aluminum-zinc alloy coated steel sheet, which are machined and bent by machine tool and then bolted;
3.2. all the operations are under the door closing condition
3.3. with high protection category, can prevent intruding of sundries and insects
3.4. simple efficient 5 protection function can prevent operating incorrectly
3.5. the removing compartment of the switchgear may be assembled with VS1(ZN63A) or VD4 vacuum circuit breaker according to customer s demand
3.6. the replacing of VCB is simple and the interchangeability of truck is good.
3.7. the cabinet body can be installed against the wall, so the maintenance can be made in front of the cabinet and the cover area can be reduced too.
3.8. cable compartment has enough room, can connect muti-cable
3.9. high speed earthing switch is used for grounding and loop short circuit
3.10. VCB vault, relay vault and cable vault can add extra heater separately according the demand of customer, in order to avoiding condensation pheromone and corrosion.
3.11. VCB vault and cable compartment can add extra lighting device separately, in order to convenient maintenance.
4. Main technical parameters
4.1 main technical of vacuum switchgear
item unit parameter
Rated voltage kV 3.6 7.2 12
Rated current A 630 1250 1600 2000 2500 3150
Rated frequency Hz 50
Rated short-time withstand current kA 16 20 25 31.5 40
Rated peak withstand current kA 40 50 63 80 100
Rated power-frequency withstand voltage kV 42/1min
Rated lightning impulse withstand voltage kV 75
Rated duration of short circuit S 4
Degree of protection IP4X
4.2main technical parameters of vacuum circuit breaker
Item Unit Parameter
Rated voltage kV 12
Rated current A 630 1250 1600 2000 2500 3150
Rated short circuit breaking current kA 25 31.5 40
Rated short-time withstand current kA 25 31.5 40
Rated short circuit making current kA 63 80 100
Rated short-time power-frequency withstand voltage kV 42/1min
Rated lightning impulse withstand voltage (peak) kV 75
Rated short circuit duration S 4
Closing time (rated voltage) ms 35 t 70
Opening time (rated voltage) ms 20 t 50
Rated breaking times of short circuit times 50 (40kAis 30)
Mechanical life times 20000
4.3main technical parameters of operation mechanism
Item Unit parameter
Rated operation voltage Opening coil V DC220/110
AC220/110
Closing coil
Rated operation current Opening coil A (DC/AC)220/110V: 0.9/1.8
Closing coil (DC/AC)220/110V: 1.0/2.0
Power of energy storage motor W 70
Rated voltage of energy storage motor V DC220/110 AC220/110
Energy storage time S 15
5. Structure instruction
The basic structure of switchgear panel comprises the panel itself and a removing part (truck). The enclosure and clap-board of the switchgear is bolted with Al-Zn alloy coated steel.Enclosure protection degree of switchgear is IP4X, and the protection degree of every vault is IP2X.
CURRENT TRASDUCER GPA
Deyang YOYIK have power plant professional accessories, non-standard pieces, to spare parts for processing. Only need to figure the number of other companies need drawings and drawings number. If you have any questions or concerns, please contact us. YOYIK has a good talent pool, the company is developing, you need to support, in order to witness its growth.
Yoyik can offer many spare parts for power plants as below:
#DF-CURRENT TRASDUCER GPA-DF
Magnetic Resistance Speed Sensor CS-1-G-065-06-01
LVDT 3000TDGN-40-01
Steam turbine bolt electric heating rod ZJ-17-13
HP CASE EXPANSION SENSOR TD-2-25
Digital temperature measuring instrument 3T-1
Bolt electric heating rod ZJ-22-14
LVDT Sensor 4000TD-15-01
Eddy Current Sensor PR6426/010-141
Hydrogen leakage detection device probe LH1500-B
FOXBORO FBM214
Eddy Current Sensor PR6422/001-001
VELOCITY SEISMOPROBE 9200-01-02-10-00
LVDT transmitter XCBSQ-02/250-01-22
Liquid LevelTransmitter with sensor GB-2100C
Sensor DF311180-50-11-00
CLOSING/TRIP COIL ZN63(VS1)-12KV VCB OF 2000A, 210 Ohm
LVDT Sensor TDZ-FRD-308
high pressure transmitter BH-209028-209
use of thermometer WSS-481 0ï½?150â?? �?8�?100 M27�?2
Electronic Module P223CB01BD5
TRANSMITTER 264DS.A.S.H.B.2.B.1.V1...L1.B1
CONTROLLER WIHT BODBUS TCP INTERFACE SPBRC410
Sensor DF311180-50-04-00
Displacement transmitter LTM-4-S2
analog pressure sensor BH-038013-03
High wear resistance thermal resistance WZPHAR2-02
Control board ME8.530.014 V2-5
Gap Sensor Cable GJCFB-15
Cable WT0182-A50-B00-C00
Blind-free two-color water meter B69H-32/2-W
Embedded intermediate relay GZY-202/220V
displacement measurement transducer LVDT TDZ-1-H 0-300
Oil pressure sensor 32302001001
Water Analyzer Transmitter CM442-45T 8/0
LVDT Sensor TD-1 300S
LVDT Sensor TDZ-1E-45
CURRENT TRANSDUCER GPA
Available used Electric Control Panels with SIEMENS Breakers, ABB VCB & Metering Panels sparingly used ready delivery available at price on weight basis. approx. quantity 40-50 MT.
photos attached.
Mechanical requiements of vacuum circuit breaker
Clearance between opening contacts: 11±1 mm
Average opening speed(Contacts closing position~75% contacts opening distance): 1.1±0.2 m/s
Average closing speed(30% contacts opening distance~contacts closing position): 0.6±0.2 m/s
Rated contacts pressure: 3150±200 N
Contacts bouncing duration at closing operation: â?¤2 ms
Contacts re-bouncing clearance at opening operation: â?¤2 mm
Synchronism of three phases: â?¤1 ms
1. General
HVD32 ZW32 12kv 630A This vacuum circuit breaker VCB is three-phase AC 50Hz, rated voltage 12 kV outdoor high voltage switch equipment. It is mainly used to opening(closing) load current, overload current and short-circuit current. It is suitable to protect or control the city or village electrical power distribution system.
2 . Main technical parameter
Rated voltage: 12 kv
1 minute rated power frequency withstand voltage: Phase to Phase, to Ground 42 kv / Fracture 48 kv
Rated current: 630A
Rated short circuit breaking current: 12.5KA, 16KA, 20KA
Rated short-circuit current (peak): 31.5KA, 40KA, 50KA
Rated peak withstand current: 31.5KA, 40KA, 50KA
4s rated short time withstand current: 12.5KA, 16KA, 20KA
Rated operating sequence: O-0.3s-CO-180s-CO(Electric operation)
Closing time: 30-60 ms
Opening time: 20-40 ms
Rated short circuit breaking current breaking times: 30 times
Mechanical life: 10,000 times
Secondary circuit 1 minute power frequency withstand voltage: 2000 v
Energy storage motor rated power: 40 w
Energy storage motor rated voltage V: DC220/110
Rated closing operation voltage v: DC220/110, AC220/110
Rated switching operation voltage v: DC220/110, AC220/110
Electric energy storage time: 8 s
1. General
HVD32 ZW32 This vacuum circuit breaker VCB is three-phase AC 50Hz, rated voltage 12 kV outdoor high voltage switch equipment. It is mainly used to opening(closing) load current, overload current and short-circuit current. It is suitable to protect or control the city or village electrical power distribution system.
2 . Main technical parameter
Rated voltage: 12 kv
1 minute rated power frequency withstand voltage: Phase to Phase, to Ground 42 kv / Fracture 48 kv
Rated current: 630A / 1250A
Rated short circuit breaking current: 12.5KA, 16KA, 20KA / 25KA
Rated short-circuit current (peak): 31.5KA, 40KA, 50KA / 63KA
Rated peak withstand current: 31.5KA, 40KA, 50KA / 63KA
4s rated short time withstand current: 12.5KA, 16KA, 20KA / 25KA
Rated operating sequence: O-0.3s-CO-180s-CO(Electric operation)
Closing time: 30-60 ms
Opening time: 20-40 ms
Rated short circuit breaking current breaking times: 30 times
Mechanical life: 10,000 times
Secondary circuit 1 minute power frequency withstand voltage: 2000 v
Energy storage motor rated power: 40 w
Energy storage motor rated voltage V: DC220/110
Rated closing operation voltage v: DC220/110, AC220/110
Rated switching operation voltage v: DC220/110, AC220/110
Electric energy storage time: =8 s
1.General
HVD85 ZN85 33kv 36KV indoor vacuum circuit breaker VCB is suitable for three-phase AC power system of 50Hz and 36kV, used to make and break the load current, overload current and fault current in industrial and mining enterprises, power plants and transformer substations, meanwhile, it is suitable for the occasion where the frequent operation is required.
2. Service conditions
2.1The ambient air temperature should be -15?~40?, the daily average temperature should not exceed 35?.
2.2 Daily mean relative humidity should not exceed 95%, and the daily mean vapor pressure should not exceed 2.2kPa; the monthly mean relative humidity should not be higher than 90%, and the monthly mean vapor pressure should not exceed 1.8kPa.
2.3 Altitude: Not exceed 1,000m.
2.4 The ambient air should be free from the dust, smoke, corrosive and flammable gas, steam, salt fog, et…
Main specifications and technical parameters
Rated voltage: 33KV 36kv
Power frequency withstand voltage: 95 kv
Lighting impulse withstand voltage: 185 kv
Rated current: 1250A, 1600A, 2000A
Rated short-time withstand current: 25KA, 31.5KA
Rated peak value withstand current: 63KA, 80KA
Rated short-circuit duration: 4 s
Rated short-circuit breaking current: 25KA, 31.5KA
Rated short-circuit making current: 63KA, 80KA
Rated operation sequence: O-0.3s-CO-180s-CO
Breaking time:
HCJ5 1.14kv 125A vacuum interrupter for vacuum contactor
1. Brief introduction
The interrupter adoption porcelain and ceramics makes to insulate the outer shell. Contact is WCCu metal alloy material advanced technique of adoption Including bulk small. Breaking the abiliting strong the life span is long, maintenanle is simple, no explosion dangerous, no contaminate and the noise is low. It is extensive to used for coal mine , chemical engineering, Petroleum metallurgy etc. department, more than keeping with at the multifarious operation with the bad place usage of environment
2. Vacuum Tube main technique parameter
Rated voltage: 1.14 kv
Rated current: 125A
Rated making current: 1250A
Rated breaking current: 1000A
Limiting breaking current: 1250A
Rated short-time withstand current: 1000A
Rated short-time withstand voltage: 10 kv
Mechanical life: 1000000 times
Breaking operations AC3: 150000 times
Breaking operations AC4: 6000 times
Automatic closing force of the contacts: 25±10 N
Force required to hold contacts open at full stork: 40±10 N
Circuit resistance at lowest rated contacts force: =120µO
Limiting abrasion of contacts: 2 mm
Storage life: 20 years
Internal gas pressure: =1.33×10-3 Pa
Model No.: JTD 12kv 1250A 20KA vacuum interrupter for Solid embedded poles
Rated voltage: 12 KV
Rated current: 1250A
Rated power frequency withstand voltage (1 min): 42 KV
Rated lightning impulse withstand voltage: 75 KV
Rated short circuit breaking current: 20KA
Rated short circuit making current(peak value): 50KA
Breaking operations under rated short circuit breaking current: 30 times
Rated short time withstand current: 20KA
Rated withstand current(peak value): 50KA
Rated duration of short circuit: 4 s
Mechanical life: 20,000 times
Closing force due to bellows and atmosphere: 70±40 N
Force required to hold contacts opening at full stroke: 120±50 N
Circuit resistance at lowest rated contacts force: =35µO
Storage life: 20 years
Limiting abrasion of contacts: 3 mm
Weight of moveable parts: =0.7kg
Mechanical requiements of vacuum circuit breaker
Clearance between opening contacts: 7±1 mm
Average opening speed: 1.0±0.25 m/s
Average closing speed: 0.65±0.15 m/s
Rated contacts pressure: 1600±100 N
Contacts bouncing duration at closing operation: =2 ms
Contacts re-bouncing clearance at opening operation: =2 mm
Synchronism of three phases: =1 ms