IONICS offers an extensive range of HF generators that comes in Radiography and Fluroscopy modes. The high frequency output allows for lower kV per exposure, shorter exposure and superior imaging.
i) Single Phase HF X-ray Generator with Capacitor Bank: These compact high frequency units operate at single phase input and are powered by a capacitor bank. The number of capacitors determine the maximum exposure time.
ii) HF Dual TUbe X-ray Generator for Fixed X-ray Machine: This series of X-ray generators can be connected to two X-Ray tubes - one for radiography mode and the other for radiography & fluoroscopy mode.
The high frequency dental X-ray unit consists of an inverter and HT section in a compact enclosure. It has been designed and developed for OEM application to be used for floor or wall mount systems. The high frequency output allows for lower kV per exposure, shorter exposure and superior imaging.
DESCRIPTION: Titanx
RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps
OUTPUT : 8KW
RECTIFICATION: Full Wave Rectified
TIMER: 0.06 to 5 sec
DIGITAL DISPLAY: Digital Display of mAs, kV & mA
X-RAY TUBE: XD-3/Imported
POWER SUPPLY: 230 Voltage AC, 15 Amps
LINE REGULATION: 10% 0.6max
PROTECTION: Electronic overload Protection
TUBE STAND: Floor to Ceiling Column Stand
The high quality bulgarian rose oil gained its producers scores of medals and diplomas from many exhibitions and fairs.
The rose valley in bulgaria, near the town of kazanlak, is among the major producers of attar of roses in the world.
Thanks to the specific geographic and climate conditions favorable temperatures during february, when blossoming buds formed, the maroon forest soils and frequency of the rainfalls during the rose picking in may and june, more than 3 centuries had been cultivated the famous all over the world bulgarian oil rose. This rose is used for producing the incomparable bulgarian rose attar.
Features of Digital Medical X-ray Radiographic System
PLX8200
1.The electric lift and rotatable newly designed U-shaped
frame can meet the photographic requirements of different
standing and lying positions. The U-shaped design can make
the operation much more convenient and flexible.
2.The world leading digital CCD detector can help you get
the high-definition images.
3.The leading domestic high power compact high frequency X-
ray generator and high frequency power inverter makes the
machine much more compact and more convenient without the
extra high-voltage generator and cable.
4.Newly designed photographic bed used specially for the U-
shaped arm X-ray system . The bed floating and
electromagnetic lock design makes it convenient for the
accurate position of the recumbent patients.
5.Specially designed working station for DR adopts all-
digital intelligent touchable LCD control system which is
graphic and real color. This system makes the operation
easier and more convenient.
Usage of High Quality X-ray Imaging System PLX8200
Applied to the chest, skull, spine and limbs and other parts
of the X-ray digital imaging.China high quality digital x-
ray machine is also called digital radiography x-ray system
.
z
The high frequency portable Dental X-Ray consists of an inverter and oil-filled which houses the high voltage transformer and tube. It has been designed and developed for OEM application in the high radiation output allows for lower kV per exposure, shorter exposure and superior imaging.
Mobile High frequency C-arm X-ray Machine YSX0701
C-arm X-ray Machine Introduction:
The clinical applications of this C-arm X-ray machine include orthopedics (arthroplasty, joint nailing, joint fluoroscopy, restoration and fixation for bone injury in emergency), radiology (abdominal organ angiography, gastrointestinal fluoroscopy), gynecology (uterus angiography), urology (kidney and bladder angiography), surgery (pacemaker implantation, peripheral vascular examination, etc.) and so on.
Key Features of C-arm X-ray Machine:
1. Adopts the true digital high frequency host, gets the clearest and richest image with minimum dose, greatly reduces the potential harm of x-ray to clinicians and patients.
2. The unique double displays make operation intuitive, easy and reliable.
3. The vertical and horizontal movements and rotation of C-arm are all electric maneuvered.
4. Micro-computer based controller features with failure self-diagnostic function, easy maintenance.
5. Digital interfaces optionally equip with picture collection & storage workstation, directly upgrade the digital image system, to provide a short cut for your heavy file management.
Upgraded Digital Image System of C-arm X-ray Machine:
1. Up to 100,000 static images stored in hard disk
2. Multi-image simultaneously display
3. Image processing functions: rotation, overturn lightness and contrast adjustment
4. Diagnostic report by laser printer
Technical Data:
Generator power/Frequency 3.5kw/40KHz 5kw/40KHz
Radiography KV 40-110KV 40-120KV
Radiography mA 30-70mA 24-70mA
Fluoroscopy KV 40-110KV 40-120KV
Fluoroscopy mA 0.1-5mA 0.1-5mA
Pulse fluoroscopy 0.1-8mA 0.1-8mA
Focus size 0.6í-1.5mm 0.3í-0.6mm
Stationary anode Rotation anode
Anode heat capacity 30KJ(40kHU) 150KJ(200kHU)
Heat capacity of 500KJ(667kHU) 600KJ(800kHU)
Collimator Iris, auto-tracking, variable visual field, double leaf
Focus-to-image intensifier distance(SID) 1000mm 1000mm
C-arm depth 730mm 730mm
C-arm open 815mm 815mm
C-arm arc glide with full balance 115íp 115íp
C-arm rotation(motored) í+180íp í+180íp
Upward and downward movement(motored) 400mm 400mm
Forward and backward movement(motored) 200mm 200mm
Horizontal swing angle í+12.5íp í+12.5íp
Image intensifier 9" metal screen intensifier
Camera High speed CCD camera
Monitor 14" high resolution monitor
Panel Two operation panels, automatic display error codes
Image memory Store 8 images, freeze the last image, multilevel denoise, double displays in one screen
Supply power 220V,50Hz,20A
Power capacitor 4KVA .
Specifications
Fluoroscopic capacity
Max rated capacity : tube current 4ma, tube voltage 110kv
Automatic fluoroscopy : tube voltage:40kví½110kv adjust
Automatically
Tube current : 0.3maí½4ma set manually
Manual fluoroscopy : continuous tube voltage:40kví½110kv
Continuous tube current : 0.3maí½4ma
Pulse fluoroscopy : continuous tube voltage 40kví½110kv
Continuous tube current 4.1maí½8ma
Photography capacity
Max rated capacity : 3.5 kw
Tube voltage and cur-
Rent combination : 40kví½49kv 1 í½125 mas
50kví½59kv 1 í½110 mas
60kví½69kv 1 í½90 mas
70kví½79kv 1 í½80 mas
80kví½89kv 1 í½71 mas
90kví½99kv 1 í½63 mas
100kví½110kv 1 í½40 mas
Plateholder size : 200mmíß250mm(8ísíß10ís)or
250mmíß300mmú¿10ísíß12ísú¬
X-ray tube
X-ray tube special for high frequency
Fixed anode
Dual-focus: large focus: 1.5, small focus: 0.6
Inverter frequency: 40khz
Thermal capacity: 30kj (40hu)
Videosystem
Image intensifier : image intensifier made by toshiba (9ísíó
6ísíó4.5ís)
Ccd vidicon : ultra low-light ccd camera imported from japan
Monitor : horizontal 1000 lines and vertical 800 lines,
Bandwidth : 12.5mhz,
Image/sec : 75
Ccu(central control) : recursive filter: k=8, 8 images storage,
Image upright, image overturnú¼positive &
Negative imageú+lih(last image freeze, and
Osdú¿monitor displayú¬
Structure
Directive wheel : ía90íprevolutionú¼can freely change the moving
Direction of the unit.
Ascending & descend-
Ing range of pillar : í²400mm
C-arm : forward and backward movement: 200mm
Revolution around horizontal axis: ía180íp
Revolution around vertical axis : ía15íp
Slip on orbit: 120íp(+90ípí½ -30íp)
Packing details : 2440mmíß1100mmíß1420mm
N.W. 300kgs g.W.400kgs
We have 4sets of used Detroit generators that were used as emergency power sources (Standby only) at a municipal water drainage plant in Korea. Please review the attached documents and assess
ENGINE SPECIFICATION
ENGINE MODEL Detroit Diesel 8163-7416 1232HP
ENGINE NO. 16VF013546
RPM 1,800
Cylinder 16
Injection method Direct injection
Cooling method Water Cooled
Fuel consumption rate 246â??/h
GENERATOR SPECIFICATION (AC Generator, 3Ã??, 60Hz, Brushless type
Generator Model DIG 4800
Emergency output 990 kVA / 792 kW
Continuous output 900kVA / 720kW
Voltage and Current 600 v x 86.6 A
Revolution 1800RPM
Excitation Voltage/Current 65V/10A
Power Factor 80%
Insulation Class F