Gas Permeability Tester is based on the differential pressure method and is professionally applicable to the determination of gas transmission rate as well as solubility coefficient, diffusion coefficient and permeability coefficient of plastic films, composite films, high barrier materials, sheeting, metal foils, rubber, tires and permeable membranes.
Features
The touch interface is auto-visual and easy to operate.
Pneumatic clamping improves sealing and avoids manual error.
Fully automatic process and the gas permeability, solubility coefficient and diffusion coefficient of the sample can be measured at the same time.
Three kinds of test mode (proportion, material and time) are getting to meet different requirements.
Provided standard membrane for rapid calibration to ensure the accuracy of testing data.
Widely test under various conditions with high-precise temperature and humidity control (optional).
The testing range can be expanded to meet the requirements of high transmittance test in accordance with clients' demand (can be modified).
Supporting the testing of toxic gas, flammable and explosive gas (can be modified).
Complied with GMP users' three-level authority.
Systematical analysis of testing results can be carried out.
ISP online control and upgrade function are excellent and testing function can be changed remotely according to requirements.
Specialized software is used for real-time testing display, data analysis and storage.
Principle
The pre-conditioned specimen is mounted in the gas diffusion cell as to form a sealed barrier between two chambers. The lower-pressure chamber is firstly evacuated, followed by the evacuation of the entire cell. A flow of gas is thereafter introduced into the evacuated higher-pressure chamber and a constant pressure difference is generated between two chambers. The gas permeates through the specimen from the higher pressure side into the lower side. The gas permeability and other barrier properties of the specimen can be obtained by monitoring the pressure changes in the lower chamber.
Standards
ISO 15105-1, ISO 2556, ASTM D1434, JIS K7126-1, GB/T 1038-2000, YBB 00082003.
Configurations
Standard:Â Instrument, Professional Software, Round Sample Cutter, Vacuum Grease, Fast Quantitative Filter Paper and Vacuum Pump.
Optional: Blades for Sample Cutter, Vacuum Grease, Vacuum Pump Oil, Fast Quantitative Filter Paper, Humidity Generator.
Note: 1. The air connection of the instrument is 6 mm PU Tube.
2. Customers need to prepare for air source and distilled water.
Labthink Gas Transmission Rate Testers are professional developed and manufactured for the determination of gas transmission rate as well as solubility coefficient, diffusion coefficient and permeability coefficient of plastic films, composite films, high barrier materials, sheeting, metal foils, rubber, tires, and permeable membranes.
Gas transmission rate testers applies to multiple international standards, such as ASTM, ISO, JIS Etc.
Large testing range
Temperatures adjustment available
Humidity adjustment available
High precise testing results.
Function and usage:
Gas chromatography carries out the quantitative analysis and peculiar smell testing for residual solvent on food packaging cases after printing;Test the pureness and quality of organic solvents.
Features
1. With higher ratio of function and reasonable price, economic and efficient
2. The design of the cellular integral structure is convenient for installation.
3. It can be connected to the chromatogram data work station so as to greatly improve the working efficiency.
4. With FID detector£ºHydrogen flame ionization detector for organic compounds with high sensitivity
5. With the flexible design of the packed column and capillary column injection ports.
6. Packed column and capillary column sample injectors can be selected as per actual situations. Wide column box (300, 300, 200mm)
7. In order to meet complicated analytic task, it makes use of various chromatographic columns so as to offer convenience and widen the range of the analytic samples. The advanced noise suppression system can fully eliminate the fan noise under the chromatogram working state, so as to provide you a comfortable and quiet working atmosphere.
8. The sampling device is completely vitrified with two modes of rapid vaporizing and column sample injection.
9. Bran-new pressure stabilization and various air circuit system
10. The air circuit has three different kinds of forms: Single, double and triple. It can match six-way valve, blow back, and precut equipment and so on according to the users¡¯ demands. It adopts new type pressure regulation system to ensure the re-productivity of equipment.
11. Reforming furnace can be equipped to implement microanalysis of CO and CO2.
12. Cracking furnace can be equipped to do double eight-step temperature rise with microcomputer control, man-machine conversation and simple application.
13. Advanced temperature control system
14. Adopt microcomputer control and man-machine conversation to indicate various needed temperatures of the temperature column box.
15. Column box temperature control scope: (room temperature +10C) - 400C, eight-step temperature rise.
The speed is 0 - 30C/min (increase 0.1C/min), and the temperature control precision is 0.1%.
The control point number is eight points of A type with control scope (room temperature +10C) - 400C.
16. Overheat protection function
It can freely set temperature within 400C with software program protection, and the hardwired connection adopts dual fail-safe design
Introduction
N530 for the detection of gas permeability of various films, infusion bags and other packaging materials for O2, CO2, N2 and other gases through the barrier properties. It is designed and manufactured according to the standards of ISO 2556-2001, ISO15105-1, GB / T 1038-2000, ASTM D1434-82 (2003), YBB00082003 .It has three independent testing chambers and independent temperature control system. The core is connected with computer through the USB. It can automatically judge and stop testing . The testing result is stable, curves of permeability rate ,temperature, pressure and different pressure will be shown at the same time. The test report will generate automatically while the data automatically stored. It also support TCP/IP protocol. There are three measuring range that can be enlarged.
Test principlesN 530 Gas Permeation Analyzer designed using the principle of differential pressure method, preparation samples will be placed between in the test chamber with high / low pressure , and clamping it ,then make the whole test system to have a vacuum processed, input test gas the high-pressure test chamber to ensure on both sides of the test samples have a constant pressure, the gas under the role of pressure pass through film from high-pressure chamber to the low pressure chamber to infiltrate, observe the changes pressure in low-pressure chamber to caculate barrier parameters of the sample.
Specifications
Measuring range: 0.02 ~ 50000 cm3/m2 day 0.1Mpa (Through the expansion of volume cap can test 600000 cm3/m2 day 0.1Mpa) Measurement Accuracy: 0.01cm3/m2 day 0.1MPa
Temperature range: 5 ~ 50 (standard temperature of 23 )
Temperature Accuracy: 0.01
Humidity Range: 0% RH (5 ~ 100% RH optional)
Wet control accuracy: 2% RH
Vacuum accuracy: 0.1Pa
Test pressure:-0.1Mpa ~ +0.1 Mpa
Test gas: O2, CO2, N2 and other gases
Air Pressure: 0.1Mpa ~ 0.8Mpa
Specimen size: 80mm, through an area of 50.24 cm2
Sample: 3(extension up to more pieces)
Carrier gas interface: 1 / 8 inch
Sample thickness: 2mm
Power: AC 220V /50HZ
Instrument weigh : 75 Kg.
Gloss weight: 90 Kg.
Dimension : 80 cm, 56 cm, 40 cm
Features
1. Computer automatically control three chambers of testing ,can test different samples, Configuration three independent sensors, each chamber can be set different temperatures. First creating positive and negative pressure dual-mode testing, leading international standard.
2.The sample can be tested by single chamber, or double chambers or three chambers .
3. Seperately show the curve of transmission, pressure, pressure value and temperature.
4. High or low levels of barrier test, repeat excellent performance.
5. The international advanced electromagnetic process step temperature control technology, ease lifting the temperature, variable temperature adjustable-rate, temperature control accuracy of 0.01 range.
6. High and low resistance ,two kinds of test mode7. Excellent test reproducibility.
8. An excellent environmental adaptability, no special requirements on the environment.
9. Real-time display of each point transmission, through the transmittance curve, can understand the testing process.
10. The curves of each chamber¡¯s temperature, humidity, weight, and transmission display independently, continous to display four- groups-curve, can monitor the interaction of parameters at the same time.
11. Software interface is simple and easy to operate, automatically test.
12. Overpressure protection13. Software interface is simple and easy to operate, automatically save the test report can be printed and other parameters and the transmittance curve of the report.
14. Optional pairs of air humidity controlling devices, more precise of
controlling wet;
15. Calibration method of standard film.
Type - Disposable/ Refillable
Shape - Stick
Size - J5 / J6 / J23 / J25 / J26
Color - Multi-color
Dimension - 76.7mm*21.9mm*10.8mm
Material - ABS & AS, Plastic, Steel and Metal
Rate of Leaking - Less Than 0.3%
Rate of Inflaming - Over 98%
Resit Water - 55 C
50 pieces in a single tray , 20 trays / carton ,63
cartons / palette ,23 pallets /20'FCL.
- Smooth and bright without trace of scratch or shrunken signs
- The rate of inflaming is over 98%, the inferior lighters is under 0.6%
- The time of continual inflaming can reach 2 minutes
- The tank would not explode when falling down within 1.5 meters high
- Plastic lighters,refillable, good hand feeling, Competitive price & high quality, Cheap price
Type - Disposable/ Refillable
Shape - Stick
Size - J5 / J6 / J23 / J25 / J26
Color - Multi-color
Dimension - 76.7mm*21.9mm*10.8mm
Material - ABS & AS, Plastic, Steel and Metal
Rate of Leaking - Less Than 0.3%
Rate of Inflaming - Over 98%
Resit Water - 55 C
50 pieces in a single tray , 20 trays / carton ,63
cartons / palette ,23 pallets /20'FCL.
- Smooth and bright without trace of scratch or shrunken signs
- The rate of inflaming is over 98%, the inferior lighters is under 0.6%
- The time of continual inflaming can reach 2 minutes
- The tank would not explode when falling down within 1.5 meters high
- Plastic lighters,refillable, good hand feeling, Competitive price & high quality, Cheap price
FUJI developed the first infrared gas analyzer in Japan to use mass-flow sensors. Since then, we have supplied customers with various types of gas analyzers to support environmental preservation and control efforts. These efforts include measurements of atmospheric pollution and detection of low density of SOx and NOx, generated by incinerating facilities and boilers. FUJI's gas analyzers are widely used to monitor the atmosphere to help maintain a cleaner natural environment.
50 pieces in a single tray , 20 trays / carton ,63
cartons / palette ,23 pallets /20'FCL.
- Smooth and bright without trace of scratch or shrunken signs
- The rate of inflaming is over 98%, the inferior lighters is under 0.6%
- The time of continual inflaming can reach 2 minutes
- The tank would not explode when falling down within 1.5 meters high
W301 Water Vapor permeation tester tests the water vapor transmission rate (WVTR) of packaging material.
This instrument is widely used in food industry, pharmaceutical industry, cosmetics flexible packaging materials industry(plastic film, barrier materials, sheets, metal aluminum, PVC,PVC sheets), college, university and quality institution for their water vapor transmission rate(WVTR) test and quality control.
It carries the standards of GB 1037-1988 ,GB/T 16928-1997, ASTM E96-00e1 ,ASTM D1653-03,TAPPI T464,ISO2528.
Working principle
W301 Water Vapor Permeation Tester was designed with the principle of weighting method to use weight reduction method to test the water transmittance rate (WVTR) of plastic films. Namely in the regulated temperature, relative humidity conditions, the sample two sides keep the vapor different pressure, measuring the vapor volume passed through, figure out the WVTR value. Unit is g/ m224h.
Specifications
Measurement range0.02~10000 g/ m224h
Measurement accuracy: 0.001 g/ m224h
Temp. range1545
Temp. accuracy0.1
Humidity range: 0~20%RH dry method 10~90%RH (dual-airflow humidity method, selection
Humidity accuracy: 2%RH
Sample thickness2mm
Sample no1piece
Sample dia.:80mm, transmission area 50.24cm2, (no stipulate for area in international)
Power supply: AC220V/50Hz
Features
1, Automatic test, use friendly,
2, Instrument with configuration of 240,000 true color touch screen to work independently;
3, High-precision sensors with over-range protection, continuous data collection, accurate and reliable data;
4, Automatic control temperature, low requirements for environment;
5, Software displays the status of each curve ,all the test parameters on the real time showing;
6, Work independently without computer;
7. Test precision is the same with infrared method and coulometry method;
8. Superior components ,multi-level security protection design,
9. Calibration with two method of weights and standard film;
10. CE, UL, FCC certifications.
11. Versatile operation language support.
12. Test chambers can expand to ten or even more.
Service :2 years coverage
Speedy reply, 12hrs response to customer questions
Software free update
Minor maintenance ---parts ship within 24 hrs
Major maintenance---Technical will be sent within 15 days
Free inhouse training for customer operator.
Gas stoves are the permanent appliance in most of the kitchens.These kitchen appliances are essential and used for cooking. There are wide varieties of cooking furnaces available, and you can choose depending on your requirements. They have undergone many changes, and you can find a gas stove (with) the burners of two, three, or four. You can also check out an automatic cooking furnace, as you do not need to trigger it with a lighter. A four stove appliance would allow you to cook four dishes simultaneously and are ideal for families with many members. They are available in different materials such as brass, CI , aluminium, and more with your complete gas stove made up of stainless steel & toughen glass tops.
Gas lighter, led screen protector ( not even in domestic ), refill paper cups, table runner, earing brass clamp, auto brass electric parts, cashew nuts, wire mesh, petha sweet, niwar, mohini powder, vermicompost, dry bath incubator, test tube plastic, sordium citrate tube, health care product, ornamental freshwater fish, safed musli, used polymer bag, cotton linter, auto hood cover,
areca plate, rice.
Film Shrinkage Test Equipment Film Shrinkage Tester GBK-D1
Film Shrinkage test, known as linear thermal shrink test or free shrink test, is used for analyzing the effect of temperature on heat shrinkable films made from polyethylene, ethylene copolymers and their mixtures. Basically, shrinking force, contracting force and shrinking ratio can be measured in such determination.
GBPI Film Shrinkage tester conforms to the multiple national and international standards:
ASTM D2732 - Standard Test Method for Unrestrained Linear Thermal Shrinkage of Plastic Film and Sheeting
ISO 14616 - Plastics Heatshrinkable films of polyethylene, ethylene copolymers and their mixtures Determination of
shrinkage stress and contraction stress
DIN 53369 - Testing of plastic films determination of the shrinking stress
Film Shrinkage Test Equipment GBK-D1 is used to determination of the degree of unrestrained linear thermal shrinkage and dimensional stability at different temperatures. Widely used in industries of plastic material, plastic products, petroleum, chemicals, research institute, inspection agency and so on.
Principle
This tester uses the principle of air heating to connect the tested sample to the tension sensor and displacement sensor. After reaching the maximum shrinkage force, it is placed in an external test environment with an ambient temperature of 23 to cool down.
The reference temperature, shrinkage force and displacement are recorded, and the recorded data can be used to determine the optimal shrinkage conditions of the film.