Please click here to check who's online and chat with them.

Find Verified Fire Alarm And Detection System Suppliers, Manufacturers and Wholesalers

Oct-08-14
Supplier From Gyeonggi-Do, South Korea (Republic Of Korea)
 
Intelligent fire Detection system as a high efficiency and low cost unmanned fire detection system in capable of an early detection regardless spontaneously fire or firebug.
This system is located in outdoor area such small and middle sized cultureal assets, natural monument and outdoor facilities.
Aug-23-16
 
The 6001 analogue addressable control and indicating equipment forms the central part of a fire detection and alarm

System. The fully networkable 2-wire 6001 is compatible with numens addressable devices and can also be

Connected to non-addressable devices when used with addressable input modules.

Default configuration programming facilitates out-of-box installation and rapid commissioning. A powerful and versatile

Cause-and-effect pc-based programming tool enables rapid customization with software for sites that require

Special operating features.

The 6001 comes standard with features that allows flexibility and expandability.

Single loop or 2-loop options available
Single loop, expandable to 2-loops available
Networkable, up to 4 control panels
Up to 125 addressable devices per loop
Automatic device detection on start-up
Automatic device type-code verification
2 independently programmable non-addressable a/v alarm output circuits
2 programmable fire alarm relay outputs
Fault relay output
Backlit lcd display providing 4 rows of 40 characters
16 zone fire alarm led indicators
3000 event history log
Oct-20-16
 
The 660 manual call points includes a pressure-activated displacement element to provide a safe and convenient
Way for building occupants to manually initiate a fire alarm condition.
Resetting the manual call point is achieved by inserting a key through the underside of the unit to replace the
Operating face to the quiescent position.
Pressure activated displacement element provides a safe user experience
Integral indicator to show polling and alarm activation
Resettable with simple key operation
Suitable for indoor use
Monitors for quiescent, alarm and fault conditions
Dip switch address setting
125 usable detector address settings per loop
Oct-20-16
 
The 6001 analogue addressable control and indicating equipment forms the central part of a fire detection and alarm
System. The fully networkable 2-wire 6001 is compatible with numens addressable devices and can also be connected
To non-addressable devices when used with addressable input modules.
Default configuration programming facilitates out-of-box installation and rapid commissioning. A powerful and versatile
Cause-and-effect pc-based programming tool enables rapid customization with software for sites that
Require special operating features.
The 6001 comes standard with features that allows flexibility and expandability.
Single loop or 2-loop options available
Single loop, expandable to 2-loops available
Networkable, up to 4 control panels
Up to 125 addressable devices per loop
Automatic device detection on start-up
Automatic device type-code verification
2 independently programmable non-addressable a/v alarm output circuits
2 programmable fire alarm relay outputs
Fault relay output
Backlit lcd display providing 4 rows of 40 characters
16 zone fire alarm led indicators
3000 event history log
Aug-23-16
 
SNC-300 non-addressable photoelectric smoke detectors are state-of-the-art detectors suitable for connection to

2-wire or 4-wire non-addressable fire detection control and indicating equipment, or to addressable fire detection

Control and indicating equipment that can accept non-addressable type detectors.

Advanced electronics in conjunction with a photoelectric smoke sensing chamber provide early detection of fire

And high immunity against unwanted alarms.

Photoelectric smoke sensor
Analogue detection discrimination
Dual leds for 360° visibility
2-wire and 4-wire models for dc 12 v and dc 24 v operation
4-wire model for dc 48 v operation
4-wire models available with a n/o alarm relay output
4-wire models available with auto-reset
2-wire models available with remote led output
Connects to zone monitor for use with addressable control and indicating equipment
105210 Fire Alarm And Detection System Suppliers
Short on time? Let Fire Alarm And Detection System sellers contact you.
Oct-20-16
 
The 460 manual call points includes a pressure-activated displacement element to provide a safe and convenient
Way for building occupants to manually initiate a fire alarm condition.
Resetting the manual call point is achieved by inserting a key through the underside of the unit to replace the
Operating face to the quiescent position.
Pressure activated displacement element provides a safe user experience
Integral indicator to show polling and alarm activation
Resettable with simple key operation
Suitable for indoor use
Monitors for quiescent, alarm and fault conditions
Oct-20-16
 
The 4001 non-addressable control and indicating equipment forms the central part of a fire detection and alarm
System. The 2-wire 4001 is compatible with numens non-addressable devices
The 4001 comes standard with features that allows flexibility and expandability. Default configuration programming
Facilitates out-of-box installation and rapid commissioning.
2, 4, 8, or 16 detection zones
Up to 32 non-addressable devices per alarm zone circuit
Configurable non-latching alarm zones, alarm dependency (zone coincidence detection), and output delay timer
3 access levels
Single-person test mode
Day/night mode
Manual activation of audio/visual alarm devices
Supervised auxiliary dc 24 v output
2 independently programmable non-addressable a/v alarm output circuits
2 programmable fire alarm relay outputs
Fault relay output
3 voltage-free inputs for remote reset, evacuation start/stop, and day/night mode
Supports up to 7 repeater panels
Oct-20-16
 
The 640 addressable audio/visual alarm devices are suitable for connection to 2-wire addressable fire detection
And alarm systems.
640 is loop-powered and activation is initiated by a dedicated initiation message from the control and indicating
Equipment. Up to 125 devices can be connected to each alarm zone loop.
Visual, audible and audio/visual models available
Red or white body available for audible alarm device
Loop-powered from control and indicating equipment
Operates when a dedicated activation message is received from the control and indicating equipment
Loud sounder output of 85 db at 1 m
Long-life leds
Low quiescent current
Dip switch address setting
Apr-09-21
 
A fire alarm system is a set of electric/electronic devices/equipment working together to detect and alert people through visual and audio appliances when smoke/fire is present. These alarms may be activated from smoke detectors, heat detectors, water flow sensors, which are automatic or from a manual fire alarm pull station.

Types of Fire Alarm System:
All Fire Alarm Systems essentially operate on the same principle. If a detector detects smoke or heat or someone operates a break glass unit (manual break point), then alarm sounders operate to warn others in the building that there may be a fire and to evacuate. It may also incorporate remote signaling equipment which would alert the fire brigade via a central station.

Conventional Fire Alarm System
In a Conventional Fire Alarm System, a number of call points and detectors are wired to the Fire Alarm Control Panel in Zones. A Zone is a circuit and typically one would wire a circuit per floor or fire compartment. The Fire Alarm Control Panel has a number of Zone Lamps. The reason for having Zones is to give a rough idea as to where a fire has occurred. This is important for the fire brigade and of course for the building management. The accuracy of knowing where a fire has started is controlled by the number of Zones a Control Panel has and the number of circuits that have been wired within the building. The Control Panel is wired to a minimum of two sounder circuits which could contain bells, electronic sounders or other audible devices. Each circuit has an end of line device which is used for monitoring purposes.

Addressable Fire Alarm System
The detection principle of an Addressable System (Fire Alarm System) is similar to a Conventional System except that the Control Panel can determine exactly which detector or call point has initiated the alarm. The detection circuit is wired as a loop and multi devices may be connected to each loop. The detectors are essentially Conventional Detectors, with an address built in. The address in each detector is set by dil switches and the Control Panel is programmed to display the information required when that particular detector is operated. Additional Field Devices are available which may be wired to the loop for detection only i.e. it is possible to detect a normally open contact closing such as sprinkler flow switch, or a normally closed contact opening.

Fire Alarm System comes with single loop as well as multi loops. It depends on requirement. The items which are integrated with Fire Alarm Systems are given belowâ?¦.

Brands are available : AGNI, MORLEY, NOTIFIER,

Modern Technologies gives you top class branded Fire Alarm System with affordable price. We also provide installation & maintenance services.
Oct-20-16
 
Snc-300 non-addressable photoelectric smoke/heat detectors are state-of-the-art detectors suitable for connection
To 2-wire or 4-wire non-addressable fire detection control and indicating equipment, or to addressable fire detection
Control and indicating equipment that can accept non-addressable type detectors.
Advanced electronics in conjunction with a photoelectric smoke sensing chamber and an electronic thermistor
Provide early detection of fire and high immunity against unwanted alarms. The heat sensor provides sensitive
Rate-of-rise operation or fixed-temperature operation when the response threshold value is exceeded.
Photoelectric smoke and heat sensors
Analogue detection discrimination
Dual leds for 360° visibility
2-wire and 4-wire models for dc 12 v and dc 24 v operation
4-wire model for dc 48 v operation
4-wire models available with a n/o alarm relay output
4-wire models available with auto-reset
2-wire models available with remote led output
Connects to zone monitor for use with addressable control and indicating equipment
Feb-16-20
Supplier From Quezon, Philippines
Feb-02-18
Supplier From Ludhiana, Punjab, India
Aug-23-16
 
SNA-360 analogue addressable photoelectric smoke/heat detectors are microprocessor controlled state-of-the-art

Detectors compatible with popular control and indicating equipment loop protocols.

Advanced electronics in conjunction with a photoelectric smoke sensing chamber and an electronic thermistor provide

Early detection of fire and high immunity against unwanted alarms. The heat sensor provides sensitive rate-of-rise

Operation or fixed-temperature operation when the response threshold value is exceeded.

Photoelectric smoke and heat sensors
Analogue detection discrimination
Dual leds for 360° visibility
Dc 24 v operation
2-wire connection to many popular loop protocols
Dip switch address setting
125 usable detector address settings per loop
Optional remote led output
Aug-23-16
 
HNC-310 non-addressable heat detectors are suitable for connection to 2-wire non-addressable fire detection control

And indicating equipment, or to addressable fire detection control and indicating equipment that can accept

Non-addressable type detectors.

An electronic thermistor provides sensitive rate-of-rise operation or fixed-temperature operation when the response

Threshold value is exceeded.

Durable heat sensor
Analogue detection discrimination
Dual leds for 360° visibility
2-wire and 4-wire models for dc 12 v and dc 24 v operation
Dual leds for 360° visibility
4-wire models available with a n/o alarm relay output
4-wire models available with auto-reset
2-wire models available with remote led output
Connects to zone monitor for use with addressable control and indicating equipment
Oct-20-16
 
The 640 addressable audio/visual alarm devices are suitable for connection to 2-wire addressable fire detection
And alarm systems.
640 is loop-powered and activation is initiated by a dedicated initiation message from the control and indicating
Equipment. Up to 125 devices can be connected to each alarm zone loop.
Visual, audible and audio/visual models available
Red or white body available for audible alarm device
Loop-powered from control and indicating equipment
Operates when a dedicated activation message is received from the control and indicating equipment
Loud sounder output of 85 db at 1 m
Long-life leds
Low quiescent current
Dip switch address setting
Oct-20-16
 
The 442 audio/visual alarm devices are suitable for connection to 2-wire and 4-wire fire detection and alarm
Systems.
441 will operate with both addressable and non-addressable fire detection control and indicating equipment.
Activation is initiated upon connection of the operating voltage, allowing connection to either a switched supply or
Via an addressable module.
Visual, audible and audio/visual models available
Red or white body available for audible alarm device
Operates when the supply voltage is connected to the device
Compatible with relay outputs from control and indicating equipment, or from an output module connected to addressable alarm circuit wiring
Dc 24 v operation
Loud sounder output of 85 db at 1 m
Long-life leds
Zero current load in quiescent condition
Oct-20-16
 
The 442 audio/visual alarm devices are suitable for connection to 2-wire and 4-wire fire detection and alarm systems.
441 will operate with both addressable and non-addressable fire detection control and indicating equipment.
Activation is initiated upon connection of the operating voltage, allowing connection to either a switched supply or via
An addressable module.
Visual, audible and audio/visual models available
Red or white body available for audible alarm device
Operates when the supply voltage is connected to the device
Compatible with relay outputs from control and indicating equipment, or from an output module connected to addressable alarm circuit wiring
Dc 24 v operation
Loud sounder output of 85 db at 1 m
Long-life leds
Zero current load in quiescent condition
Oct-20-16
 
Snd-500 dc smoke alarms provide battery powered smoke detection and alarm functions within a single unit.
Advanced electronics in conjunction with a photoelectric smoke sensing chamber provide early detection of fire
And high immunity against unwanted alarms.
Snd-500 dc smoke alarms are battery powered, do not require a mains supply, and are suitable for general
Residential applications.
Photoelectric smoke sensor
Integrated indicator provides visual indication of an alarm condition
Test button verifies battery and alarm operation
Loud 85 db sounder to alert occupants
Single dc 9 v user-replaceable battery provides up to 18 months operation under normal conditions
30 day low battery warning signal
Interconnection function available to connect up to 38 units together
Battery missing indicator
Apr-03-19
 
Model No.
SR-820DHS

Operating voltage
9V battery

Interconnection
N/A

Alarm temperature
57

Sensitivity
2.06%ft±1.3%ft

Sound level
85dB/3m

Installation
Wall or Ceiling mounted

Working environment
-10~+50(â?¤95%RH No congelation)

Dimension
128*38mm
Jul-21-06
Supplier From Mumbai, Maharashtra, India
105210 Fire Alarm And Detection System Suppliers
Short on time? Let Fire Alarm And Detection System sellers contact you.
Explore Fire Alarm And Detection System related import export discussions