Please click here to check who's online and chat with them.

Find Verified Analogue Input Module T8403 T8403C P8403 Suppliers, Manufacturers and Wholesalers

Mar-25-20
 
Description
The Trusted TMR 24V dc digital input module interfaces to 40 field input devices. A wide input voltage range and programmable thresholds allow the module to be used in current source and current sink configurations. Comprehensive diagnostic tests are performed on each input channel, including tests for stuck on and stuck off failures. Fault tolerance is achieved through Triple Modular Redundancy (TMR) within the same module for each of the 40 input channels.
When a line-monitoring device is installed at the field switch, the module can detect open and shorted field cables. Line monitoring can be independently configured for each input channel.
The module provides on-board sequence of events (SOE) reporting with a resolution of 1ms. A change of state triggers an SOE entry. States are determined by programmable voltage thresholds that can be configured on a per channel basis. When the field voltage and field return are connected to the auxiliary input channels of the module, thresholds can be specified as a ratio of the current field supply voltage.
Each triplicated section of the module, referred to as a slice, conditions and measures each channel independently. Each slice is optically isolated up to 2500V dc. Each slice sends its data to a safety layer hardware voter that presents the information from all three slices to the Trusted TMR processor. When a fault is detected on a slice of the module, the Trusted TMR processor will flag the error, indicating the need to replace the module. The Trusted TMR processor will continue to use the information provided by the remaining two slices until a replacement module is available. Replacement modules can be located in a standby slot next to the module or in a designated SmartSlot with a temporary connection to the same Trusted termination assembly.
Modules may be placed in any I/O module slot in a Trusted processor chassis or expander chassis. Once the I/O module configuration is set, mechanical keying is available on all I/O modules to prevent inserting a module into an incorrect slot.
Configuration of the module is carried out using the Trusted Toolset running on an engineering workstation. Once configured and loaded into the Trusted controller, replacement modules are online educated by the TMR processor.

Features
40 TMR input channels per module.
Comprehensive diagnostics and self-test.
Line monitoring on a per channel basis.
2500V dc optically isolation.
On-board 1ms resolution sequence of events reporting.
Hot replaceable.
Front panel status LEDs for each channel.
Module fault and status indicators.
IEC 61508, SIL 3 safety applications.
Mar-25-20
 
Description
The Trusted TMR analogue input module interfaces to 40 single-ended field input devices. A wide input range and programmable thresholds allow the module to be used in most voltage or current configurations. Comprehensive diagnostic tests are performed on each input channel, including tests for out of range values and stuck at failures. Fault tolerance is achieved through Triple Modular Redundancy (TMR) within the same module for each of the 40 input channels.
The module can apply a digital filter to each input channel. Individual channels can be configured for high noise immunity (50Hz or 60Hz rejection), low noise immunity (fast response) or pass-through operation (no filtering).
Each input channel has four configurable state thresholds, which may be assigned to SOE reporting. A change of state triggers an SOE entry. The on-board sequence of events (SOE) reporting has a resolution of 1ms.
Each triplicated section of the module, referred to as a slice, conditions and measures each channel independently. Each slice is optically isolated up to 2500V dc. Each slice sends its data to a safety layer hardware voter that presents the information from all three slices to the Trusted TMR processor. When a fault is detected on a slice of the module, the Trusted TMR processor will flag the error, indicating the need to replace the module. The Trusted TMR processor will continue to use the information provided by the remaining two slices until a replacement module is available. Replacement modules can be located in a standby slot next to the module or in a designated SmartSlot with a temporary connection to the same Trusted termination assembly.
Modules may be placed in any I/O module slot in a Trusted processor chassis or expander chassis. Once the I/O module configuration is set, mechanical keying is available on all I/O modules to prevent inserting a module into an incorrect slot.
Configuration of the module is carried out using the Trusted Toolset running on an engineering workstation. Once configured and loaded into the Trusted controller, replacement modules are online educated by the TMR processor.

Features
40 TMR input channels per module.
Comprehensive diagnostics and self-test.
2500V dc optically isolation.
Digital signal filtering on a per channel basis.
Four user configurable thresholds per channel.
On-board 1ms resolution sequence of events reporting.
Hot replaceable.
Front panel status LEDs for each channel.
Module fault and status indicators.
IEC 61508, SIL 3 safety applications.
VERIFIED
Feb-16-22
 
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic.
Functional details
1. Hot plug
Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system.
2. Advanced current sharing technology
Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A.
3. Control of input limited power
Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode.
4. Control of output constant power
When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module.
The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V.
The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage.
5. Temperature limited power
6. Regulation of output current limiting point
8. Regulation of output voltage
The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc.
9. Fan control
The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module.
10. Protection of input overvoltage/ voltage shortage
11. Output overvoltage protection
The overvoltage protection point is 260Vdc ~770Vdc ( +10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection.
12. Over-temperature protection
The environmental over-temperature protection point is 80 C. When the DC panel has a temperature over 100 C, the module will stop working; when the DC panel has a temperature below 90 C, the module will automatically work again.
13. Protection of internal bus fault
When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on.
14. Short circuit protection
In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".
VERIFIED
Feb-17-22
 
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic.
Functional details
1. Hot plug
Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system.
2. Advanced current sharing technology
Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A.
3. Control of input limited power
Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode.
4. Control of output constant power
When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module.
The SD75200 module uses two operating modes with output voltage ranges of 50 to 750V.
The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage.
5. Temperature limited power
6. Regulation of output current limiting point
8. Regulation of output voltage
The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc.
9. Fan control
The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module.
10. Protection of input overvoltage/ voltage shortage
11. Output overvoltage protection
The overvoltage protection point is 260Vdc ~770Vdc (�±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection.
12. Over-temperature protection
The environmental over-temperature protection point is 80�°C. When the DC panel has a temperature over 100�°C, the module will stop working; when the DC panel has a temperature below 90�°C, the module will automatically work again.
13. Protection of internal bus fault
When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on.
14. Short circuit protection
In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".
VERIFIED
Feb-17-22
 
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic.
Functional details
1. Hot plug
Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system.
2. Advanced current sharing technology
Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A.
3. Control of input limited power
Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode.
4. Control of output constant power
When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module.
The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V.
The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage.
5. Temperature limited power
6. Regulation of output current limiting point
8. Regulation of output voltage
The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc.
9. Fan control
The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module.
10. Protection of input overvoltage/ voltage shortage
11. Output overvoltage protection
The overvoltage protection point is 260Vdc ~770Vdc (�±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection.
12. Over-temperature protection
The environmental over-temperature protection point is 80�°C. When the DC panel has a temperature over 100�°C, the module will stop working; when the DC panel has a temperature below 90�°C, the module will automatically work again.
13. Protection of internal bus fault
When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on.
14. Short circuit protection
In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".
1388 Analogue Input Module T8403 T8403C P8403 Suppliers
Short on time? Let Analogue Input Module T8403 T8403C P8403 sellers contact you.
VERIFIED
Mar-02-22
 
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic.
Functional details
1. Hot plug
Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system.
2. Advanced current sharing technology
Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A.
3. Control of input limited power
Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode.
4. Control of output constant power
When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module.
The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V.
The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage.
5. Temperature limited power
6. Regulation of output current limiting point
8. Regulation of output voltage
The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc.
9. Fan control
The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module.
10. Protection of input overvoltage/ voltage shortage
11. Output overvoltage protection
The overvoltage protection point is 260Vdc ~770Vdc (�±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection.
12. Over-temperature protection
The environmental over-temperature protection point is 80�°C. When the DC panel has a temperature over 100�°C, the module will stop working; when the DC panel has a temperature below 90�°C, the module will automatically work again.
13. Protection of internal bus fault
When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on.
14. Short circuit protection
In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".
VERIFIED
Feb-14-23
 
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic.
Functional details
1. Hot plug
Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system.
2. Advanced current sharing technology
Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A.
3. Control of input limited power
Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode.
4. Control of output constant power
When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module.
The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V.
The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage.
5. Temperature limited power
6. Regulation of output current limiting point
8. Regulation of output voltage
The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc.
9. Fan control
The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module.
10. Protection of input overvoltage/ voltage shortage
11. Output overvoltage protection
The overvoltage protection point is 260Vdc ~770Vdc (�±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection.
12. Over-temperature protection
The environmental over-temperature protection point is 80�°C. When the DC panel has a temperature over 100�°C, the module will stop working; when the DC panel has a temperature below 90�°C, the module will automatically work again.
13. Protection of internal bus fault
When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on.
14. Short circuit protection
In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".
VERIFIED
Jul-18-14
Supplier From Mumbai, Maharashtra, India
 
This smartplot paperless chart recorder is universal input data monitoring system with lcd touch screen colour graphical display. It is used to elaborate each input parameter in the form of various trends available like graphical trend, bar graph, numerical format & conventional analogue meter format. It comes with high capacity data storage & usb/ rs 485 communication interface.
Key features :

Smartplot recorder available in size of 7.1” & 10.1”
64k colours, bright & wide viewing angle tft glass with backlight
Variety of trends : bar graph, numerical format, analog format & graphical trend
Universal 8/ 16 inputs : rtd, tc & analog
True 16 bit adc for more accuracy
In-built rtc for timed & event based logging at high resolution
8mb data storage capacity (60, 000 samples/channel)
In-built 24vdc self excitation output
Firmware upgrade at user end
Real time data acquisition & data transfer
Aug-30-24
 
Our products are strictly tested and guaranteed for one year.

Why Choose MOORE AUTOMATION LIMITED ?

 12 Month Warranty
 100% new factory sealed
 We will track the goods until you received
Company Profile:
At MOOREï¼?we specialize in sourcing necessary and scarce automation components that to keep the manufacturing industry running.
Regardless of the year, scarcity or location of the part.
we will locate and deliver the parts you need
so your facility can get back up and running quickly.
FAQ

Q: Are you trading company or manufacturer ?
A: We are trading company.

Q: How long is your delivery time?
A: Generally it is 3-5days to reach your hand by Fedex if the goods are in stock.
If the goods are not in stock, Need to negotiate.

Q: What is your terms of payment ?
A: 100% T/T before shipping.

HIMA is known for its high-integrity safety systems and solutions, particularly in industrial automation. They produce a range of safety modules and control systems designed for safety-critical applications.


The following models are in stockï¼?
PROSOFT MVI56E-MNETXT
PROSOFT MVI71-AFC
PROSOFT PLX31-EIP-PND
PROSOFT 2150-AGA
PROSOFT 5205-DFNT-PDPS
PROSOFT MVI56-GEC
PROSOFT 3300-MBP
PROSOFT MVI56E-MCMR
PROSOFT MVI56-DFCMR
PROSOFT MVI56-MDA4
PROSOFT 5201-MNET-MCM
PROSOFT MVI56E-MCM
PROSOFT ILX69-PBM
PROSOFT PLX32-EIP-PND
PROSOFT 5210-DFNT-RIO
PROSOFT MVI46-GSC
PROSOFT MVI56-GSC
PROSOFT 4205-MNET-PDPS
PROSOFT MVI56E-GSC
PROSOFT PS69-DPS
PROSOFT 3100-INUSA
PROSOFT MVI56-PDPMV1
PROSOFT 3100-MDA4
PROSOFT 3100-LTQ
PROSOFT MVI94-MCM
PROSOFT MVI69-MNETC
PROSOFT 5201-DFNT-EGD
PROSOFT MVI69L-MBS
PROSOFT MVI56-EGD
PROSOFT MVI56-DFCM
PROSOFT MVI56E-MCMXT
VERIFIED
Sep-01-22
 
Product Introduction
SAND AC/DC Charger is specially developed for DC chargers module. It has high efficiency, high power factor, high power density, high reliability advantage. AC input 3 phase or single phase, DC output voltage range from 100 to 750VDC can be set, compliant with CE safety requirements, EMC standard EN61000-6-3 and EN61000-6-1 Class A, it is an advanced international level charger module.
Unique function
High efficiency over the full load range, full load efficiency greater than 95.5%
Wide output voltage range, 100-1000VDC, suitable for a wide range of Lithium and lead acid battery
5-inch LCD touch screen, easy to operate
Flexible application, charging voltage, charging current, charging time, timing charging can be set by LCD screen, easy to operate
Main features
Powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc.
Three phase active power factor correction technology, reduces the harmonic interference to the grid
Dual DSP design, achieve the full digital control, less components means high reliability
Wide input voltage range, allows operation in most poor grid conditions
Soft start charging and soft shutdown minimize the impact on the battery.
Input, output have protective circuit breaker switch
Module adopts hot pluggable design, which is convenient for maintenance.
CAN/RS485 interface
VERIFIED
Sep-01-22
 
Product Introduction
SAND AC/DC Charger is specially developed for DC chargers module. It has high efficiency, high power factor, high power density, high reliability advantage. AC input 3 phase or single phase, DC output voltage range from 100 to 750VDC can be set, compliant with CE safety requirements, EMC standard EN61000-6-3 and EN61000-6-1 Class A, it is an advanced international level charger module.
Unique function
High efficiency over the full load range, full load efficiency greater than 95.5%
Wide output voltage range, 100-1000VDC, suitable for a wide range of Lithium and lead acid battery
5-inch LCD touch screen, easy to operate
Flexible application, charging voltage, charging current, charging time, timing charging can be set by LCD screen, easy to operate
Main features
Powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc.
Three phase active power factor correction technology, reduces the harmonic interference to the grid
Dual DSP design, achieve the full digital control, less components means high reliability
Wide input voltage range, allows operation in most poor grid conditions
Soft start charging and soft shutdown minimize the impact on the battery.
Input, output have protective circuit breaker switch
Module adopts hot pluggable design, which is convenient for maintenance.
CAN/RS485 interface
VERIFIED
Mar-12-24
 
Product Introduction
SANDI AC/DC Charger is specially developed for DC chargers module. It has high efficiency, high power factor, high power density, high reliability advantage. AC input 3 phase or single phase, DC output voltage range from 100 to 750VDC can be set, compliant with CE safety requirements, EMC standard EN61000-6-3 and EN61000-6-1 Class A, it is an advanced international level charger module.
Unique function
High efficiency over the full load range, full load efficiency greater than 95.5%
Wide output voltage range, 100-750VDC, suitable for a wide range of Lithium and lead acid battery
5-inch LCD touch screen, easy to operate
Flexible application, charging voltage, charging current, charging time, timing charging can be set by LCD screen, easy to operate
Main features
Powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc.
Three phase active power factor correction technology, reduces the harmonic interference to the grid
Dual DSP design, achieve the full digital control, less components means high reliability
Wide input voltage range, allows operation in most poor grid conditions
Soft start charging and soft shutdown minimize the impact on the battery.
Input, output have protective circuit breaker switch
Module adopts hot pluggable design, which is convenient for maintenance.
CAN/RS485 interface (Optional)
VERIFIED
Jul-13-24
 
AC to DC converter battery charger 150-1000VDC rectifier 120KW power supply

Product Introductionï¼?

SANDI AC/DC Charger is specially developed for DC chargers. It has high efficiency, high power factor, high power density, high reliability advantage. AC input 3 phase, DC output voltage range from 150 to 1000VDC can be set, compliant with CE safety requirements, EMC standard EN61000-6-3 and EN61000-6-1 Class A, it is an advanced international level charger.

Unique function
High efficiency over the full load range, full load efficiency greater than 95%
Wide output voltage range, 150-1000VDC, suitable for a wide range of Lithium or lead acid battery
5-inch LCD touch screen, easy to operate
Flexible application, charging voltage, charging current, charging time, timing charging can be set by LCD screen, easy to operate
Main featuresï¼?

Powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc.
Wide input voltage range: 260~ 530Vac, adaptable to various power grid environments
Three-phase AC input without neutral wire: Simplifies system design, eliminates the risk of excessive neutral current, and reduces system costs.
Dual DSP design, achieve the full digital control, less components means high reliability
Wide input voltage range, allows operation in most poor grid conditions
Battery anti backflow: effectively protects the battery while ensuring reliable and safe operation of the system
Input, output have protective circuit breaker switch
Module adopts hot pluggable design, which is convenient for maintenance.
RS485 interface (Optional)
VERIFIED
Jun-07-21
 
BRAND: WEST PID TEMPERATURE CONTROLLER
WEST Controller:
Model: WEST-6100+,P6100
Model: WEST-4100+,P4100
Model: WEST-8100+,P8100
Features and Benefits:
Dual setpoints & optional remote selection
Plug-in output modules allow installing just the functions needed in
Expanded user-selectable operator modes in
User-selectable plug-and-play output cards in
Process and loop alarms in
Adjustable hysteresis in
Optional 10V SSR driver in
Improved Windows PC configuration software
Improved easy-to-use HMI
Jumperless input configuration
Auto-hardware recognition
Faster communication speeds
More security options
Backward compatible panel cutout, housing and terminal wiring capability
P6100/P6170/P8100/P4100
VERIFIED
Feb-12-22
 
1, The core components are all imported, adopting the sixth generation IPM module from Mitsubishi, which has stable performance, long service life, strong protection functions and convenient replacement and maintenance.
2, Adopt the central processor DSP28335 chip from American TI Company, respond quickly and accurately, and provide stable and clean power for the load to provide protection.
3, The whole machine adopts modular design and plug-in design, which is convenient for maintenance and reduces the hidden cost of machine failure to repair.
4, According to the product configuration conditions, adjustment the system usage mode: DC(Battery/Solar) priority or AC mains bypass priority can be set.
5, Two kinds of start mode: Reduction Voltage Start and Variable Frequency Start. Customers can set start mode according to the type of their load. This function is very convenient for users and also reduce frequency converter's usage, which reduced the cost of equipment investment, easy to connect wires and control.
6, The output voltage can be set between -40 % to +20 % of rated voltage. And the output voltage is very accuracy ±1%.
7, The DC input voltage range can be set. Over-voltage point, under-voltage point, over-voltage recovery point, under-voltage recovery point all can be setting via the LCD panel.
8, Output AC Power is suitable for all types of electrical equipment, CNC machines, electric tools, motors, pump and air conditioner etc. It has higher efficiency and higher capability of driving load.
9, Humanized safety design, using isolation transformer design, input and output are completely electrically isolated, input and output are equipped with circuit breakers, which saving costs for the user and easy to installation, the electric parts are completely closed to prevent electric shock.
10, Wide input voltage can be set according to customerâ??s requirement. Input voltage range can be selected from 100-300V, 200-500V or 500-850V, suitable for solar/wind system without backup batteries, it can save many cost and maximization use the solar/wind energy.
11, Using SVPWM space vector algorithms, high conversion efficiency, high instantaneous power and low losses conversion efficiency up to 94%.
12, Powerful data display function. LCD + LED display, can display input and output voltage, current, KWH, fault display, convenient for customers to quickly find faults and guide maintenance.
13, European CE (EMC, LVD, UL1741) and ISO9001 certificates.
VERIFIED
Feb-12-22
 
1, The core components are all imported, adopting the sixth generation IPM module from Mitsubishi, which has stable performance, long service life, strong protection functions and convenient replacement and maintenance.
2, Adopt the central processor DSP28335 chip from American TI Company, respond quickly and accurately, and provide stable and clean power for the load to provide protection.
3, The whole machine adopts modular design and plug-in design, which is convenient for maintenance and reduces the hidden cost of machine failure to repair.
4, According to the product configuration conditions, adjustment the system usage mode: DC(Battery/Solar) priority or AC mains bypass priority can be set.
5, Two kinds of start mode: Reduction Voltage Start and Variable Frequency Start. Customers can set start mode according to the type of their load. This function is very convenient for users and also reduce frequency converter's usage, which reduced the cost of equipment investment, easy to connect wires and control.
6, The output voltage can be set between -40 % to +20 % of rated voltage. And the output voltage is very accuracy ±1%.
7, The DC input voltage range can be set. Over-voltage point, under-voltage point, over-voltage recovery point, under-voltage recovery point all can be setting via the LCD panel.
8, Output AC Power is suitable for all types of electrical equipment, CNC machines, electric tools, motors, pump and air conditioner etc. It has higher efficiency and higher capability of driving load.
9, Humanized safety design, using isolation transformer design, input and output are completely electrically isolated, input and output are equipped with circuit breakers, which saving costs for the user and easy to installation, the electric parts are completely closed to prevent electric shock.
10, Wide input voltage can be set according to customerâ??s requirement. Input voltage range can be selected from 100-300V, 200-500V or 500-850V, suitable for solar/wind system without backup batteries, it can save many cost and maximization use the solar/wind energy.
11, Using SVPWM space vector algorithms, high conversion efficiency, high instantaneous power and low losses conversion efficiency up to 94%.
12, Powerful data display function. LCD + LED display, can display input and output voltage, current, KWH, fault display, convenient for customers to quickly find faults and guide maintenance.
13, European CE (EMC, LVD, UL1741) and ISO9001 certificates.
VERIFIED
Feb-12-22
 
1, The core components are all imported, adopting the sixth generation IPM module from Mitsubishi, which has stable performance, long service life, strong protection functions and convenient replacement and maintenance.
2, Adopt the central processor DSP28335 chip from American TI Company, respond quickly and accurately, and provide stable and clean power for the load to provide protection.
3, The whole machine adopts modular design and plug-in design, which is convenient for maintenance and reduces the hidden cost of machine failure to repair.
4, According to the product configuration conditions, adjustment the system usage mode: DC(Battery/Solar) priority or AC mains bypass priority can be set.
5, Two kinds of start mode: Reduction Voltage Start and Variable Frequency Start. Customers can set start mode according to the type of their load. This function is very convenient for users and also reduce frequency converterâ??s usage, which reduced the cost of equipment investment, easy to connect wires and control.
6, The output voltage can be set between -40 % to +20 % of rated voltage. And the output voltage is very accuracy �±1%.
7, The DC input voltage range can be set. Over-voltage point, under-voltage point, over-voltage recovery point, under-voltage recovery point all can be setting via the LCD panel.
8, Output AC Power is suitable for all types of electrical equipment, CNC machines, electric tools, motors, pump and air conditioner etc. It has higher efficiency and higher capability of driving load.
9, Humanized safety design, using isolation transformer design, input and output are completely electrically isolated, input and output are equipped with circuit breakers, which saving costs for the user and easy to installation, the electric parts are completely closed to prevent electric shock.
10, Wide input voltage can be set according to customer's requirement. Input voltage range can be selected from 100-300V, 200-500V or 500-850V, suitable for solar/wind system without backup batteries, it can save many cost and maximization use the solar/wind energy.
11, Using SVPWM space vector algorithms, high conversion efficiency, high instantaneous power and low losses conversion efficiency up to 94%.
12, Powerful data display function. LCD + LED display, can display input and output voltage, current, KWH, fault display, convenient for customers to quickly find faults and guide maintenance.
13, European CE (EMC, LVD, UL1741) and ISO9001 certificates.
[Optional]
A, RS485 communication;
B, AC bypass complementary function;
C, Built-in charger
VERIFIED
Feb-12-22
 
1, The core components are all imported, adopting the sixth generation IPM module from Mitsubishi, which has stable performance, long service life, strong protection functions and convenient replacement and maintenance.
2, Adopt the central processor DSP28335 chip from American TI Company, respond quickly and accurately, and provide stable and clean power for the load to provide protection.
3, The whole machine adopts modular design and plug-in design, which is convenient for maintenance and reduces the hidden cost of machine failure to repair.
4, According to the product configuration conditions, adjustment the system usage mode: DC(Battery/Solar) priority or AC mains bypass priority can be set.
5, Two kinds of start mode: Reduction Voltage Start and Variable Frequency Start. Customers can set start mode according to the type of their load. This function is very convenient for users and also reduce frequency converter's usage, which reduced the cost of equipment investment, easy to connect wires and control.
6, The output voltage can be set between -40 % to +20 % of rated voltage. And the output voltage is very accuracy �±1%.
7, The DC input voltage range can be set. Over-voltage point, under-voltage point, over-voltage recovery point, under-voltage recovery point all can be setting via the LCD panel.
8, Output AC Power is suitable for all types of electrical equipment, CNC machines, electric tools, motors, pump and air conditioner etc. It has higher efficiency and higher capability of driving load.
9, Humanized safety design, using isolation transformer design, input and output are completely electrically isolated, input and output are equipped with circuit breakers, which saving costs for the user and easy to installation, the electric parts are completely closed to prevent electric shock.
10, Wide input voltage can be set according to customerâ??s requirement. Input voltage range can be selected from 100-300V, 200-500V or 500-850V, suitable for solar/wind system without backup batteries, it can save many cost and maximization use the solar/wind energy.
11, Using SVPWM space vector algorithms, high conversion efficiency, high instantaneous power and low losses conversion efficiency up to 94%.
12, Powerful data display function. LCD + LED display, can display input and output voltage, current, KWH, fault display, convenient for customers to quickly find faults and guide maintenance.
13, European CE (EMC, LVD, UL1741) and ISO9001 certificates.
[Optional]
A, RS485 communication;
B, AC bypass complementary function;
C, Built-in charger
VERIFIED
Feb-12-22
 
1, The core components are all imported, adopting the sixth generation IPM module from Mitsubishi, which has stable performance, long service life, strong protection functions and convenient replacement and maintenance.
2, Adopt the central processor DSP28335 chip from American TI Company, respond quickly and accurately, and provide stable and clean power for the load to provide protection.
3, The whole machine adopts modular design and plug-in design, which is convenient for maintenance and reduces the hidden cost of machine failure to repair.
4, According to the product configuration conditions, adjustment the system usage mode: DC(Battery/Solar) priority or AC mains bypass priority can be set.
5, Two kinds of start mode: Reduction Voltage Start and Variable Frequency Start. Customers can set start mode according to the type of their load. This function is very convenient for users and also reduce frequency converter usage, which reduced the cost of equipment investment, easy to connect wires and control.
6, The output voltage can be set between -40 % to +20 % of rated voltage. And the output voltage is very accuracy �±1%.
7, The DC input voltage range can be set. Over-voltage point, under-voltage point, over-voltage recovery point, under-voltage recovery point all can be setting via the LCD panel.
8, Output AC Power is suitable for all types of electrical equipment, CNC machines, electric tools, motors, pump and air conditioner etc. It has higher efficiency and higher capability of driving load.
9, Humanized safety design, using isolation transformer design, input and output are completely electrically isolated, input and output are equipped with circuit breakers, which saving costs for the user and easy to installation, the electric parts are completely closed to prevent electric shock.
10, Wide input voltage can be set according to customer requirement. Input voltage range can be selected from 100-300V, 200-500V or 500-850V, suitable for solar/wind system without backup batteries, it can save many cost and maximization use the solar/wind energy.
11, Using SVPWM space vector algorithms, high conversion efficiency, high instantaneous power and low losses conversion efficiency up to 94%.
12, Powerful data display function. LCD + LED display, can display input and output voltage, current, KWH, fault display, convenient for customers to quickly find faults and guide maintenance.
13, European CE (EMC, LVD, UL1741) and ISO9001 certificates.
[Optional]
A, RS485 communication;
B, AC bypass complementary function;
C, Built-in charger
VERIFIED
Feb-12-22
 
1, The core components are all imported, adopting the sixth generation IPM module from Mitsubishi, which has stable performance, long service life, strong protection functions and convenient replacement and maintenance.
2, Adopt the central processor DSP28335 chip from American TI Company, respond quickly and accurately, and provide stable and clean power for the load to provide protection.
3, The whole machine adopts modular design and plug-in design, which is convenient for maintenance and reduces the hidden cost of machine failure to repair.
4, According to the product configuration conditions, adjustment the system usage mode: DC(Battery/Solar) priority or AC mains bypass priority can be set.
5, Two kinds of start mode: Reduction Voltage Start and Variable Frequency Start. Customers can set start mode according to the type of their load. This function is very convenient for users and also reduce frequency converter usage, which reduced the cost of equipment investment, easy to connect wires and control.
6, The output voltage can be set between -40 % to +20 % of rated voltage. And the output voltage is very accuracy ±1%.
7, The DC input voltage range can be set. Over-voltage point, under-voltage point, over-voltage recovery point, under-voltage recovery point all can be setting via the LCD panel.
8, Output AC Power is suitable for all types of electrical equipment, CNC machines, electric tools, motors, pump and air conditioner etc. It has higher efficiency and higher capability of driving load.
9, Humanized safety design, using isolation transformer design, input and output are completely electrically isolated, input and output are equipped with circuit breakers, which saving costs for the user and easy to installation, the electric parts are completely closed to prevent electric shock.
10, Wide input voltage can be set according to customerâ??s requirement. Input voltage range can be selected from 100-300V, 200-500V or 500-850V, suitable for solar/wind system without backup batteries, it can save many cost and maximization use the solar/wind energy.
11, Using SVPWM space vector algorithms, high conversion efficiency, high instantaneous power and low losses conversion efficiency up to 94%.
12, Powerful data display function. LCD + LED display, can display input and output voltage, current, KWH, fault display, convenient for customers to quickly find faults and guide maintenance.
13, European CE (EMC, LVD, UL1741) and ISO9001 certificates.
[Optional]
A, RS485 communication;
B, AC bypass complementary function;
C, Built-in charger
1388 Analogue Input Module T8403 T8403C P8403 Suppliers
Short on time? Let Analogue Input Module T8403 T8403C P8403 sellers contact you.

About Fertilizers and Pesticides

Using fertilizer products, pesticides, and seeds is crucial in agriculture as quality input produces quality output, supports sustainable farming, and meets the ever-growing demand for quality food. This is because as the world looks for new and improved ways to boost agricultural production, farmers need to get their hands on good fertilizer manufacturers and pesticide suppliers for fertilizer products to continue growing quality produce. At go4WorldBusiness.com, we assist buyers in getting in touch with verified agrochemical manufacturers and seed suppliers and help them get the right fertilizer products they require for their farming needs.

Types of Agriculture Fertilizers Manufacturers

Let’s look at some of the different  types of fertilizer products that are used in agriculture to promote crop growth and improve soil conditions: 

  • NPK Fertilizer: NPK Fertilizer is a balanced nutrient mix that can be used to provide most crops with all the necessary nutrients. 
  • Urea 46 Fertilizer: Urea 46 Fertilizer is rich in nitrogen, promoting plant growth and making plants look greener. 
  • Liquid Fertilizer: These are easy to apply and ensure that nutrients are distributed evenly across the farm in equal proportion. 
  • Organomineral fertilizer: This is a combination of organic and mineral fertilizers that improves the soil's efficiency. 
  • MAP Fertilizer (Monoammonium  Phosphate): This product is mainly used in phosphorus-stunted soils since it contains high phosphorus. 
  • Nitrogen Fertilizer: Nitrogen Fertilizer enhances crop yield by adding nitrogen to the soil. 
  • Vermicompost Fertilizer: Vermicompost is a natural soil conditioning manure that enhances the soil structure. 
  • Seaweed Extract Powder is a natural product containing several micro-nutrients that enhance plant growth and ensure plant health and disease resistance. 

Features and Benefits of  Agrochemical Manufacturers

Using high-quality agrochemicals provides several advantages: 

  • Improved Efficiency: This will reduce manual effort while helping you make more advanced formulations to keep your crops weed and disease-free. 
  • Faster Production: Increase crop yields within shorter timelines to match the ever-growing demand. 
  • Minimized Waste: Ensure optimal use of resources, reducing excess application. 

Why Choose go4WorldBusiness.com?

It has never been easier for businesses to search for agrochemical manufacturers and seed suppliers. Here’s why buyers and sellers trust go4WorldBusiness.com: 

  • Verified Suppliers: go4WorldBusiness.com ensures that you connect with verified and trusted fertilizer manufacturers and pesticide suppliers who are reliable and trustworthy. 
  • Extensive Product Range: go4WorldBusiness.com has everything you need, including fertilizer products, pesticides, and seeds. 
  • Competitive Pricing: Get affordable fertilizer products and services for all farming requirements. 
  • Global Shipping: Reach wholesale fertilizer suppliers from across the globe, ensuring timely delivery. 

Conclusion 

Take your farm to the next level by acquiring good quality fertilizer products, pesticides, and seeds and connect with reliable and trusted wholesale fertilizer suppliers only on go4WorldBusiness.com. Go through various available fertilizer products, compare them to find out which products suit your agricultural needs, and access the contact details of verified sellers.