Please click here to check who's online and chat with them.

Find Verified Temperature Controllers Indicators Suppliers, Manufacturers and Wholesalers

Mar-27-12
 
Various types of thermocouple
Can be widely supplied as
Customer's requirment--good
Erosion-resistant, corrosion-resistant

1) Thermocouples specified for food, health, medicine, and light industries
2) Inert-gas-filled thermocouples and thermocouples for temperature measurement on ships
3) Thermocouples with stainless steel terminal box

Features:
1) Complete stainless steel structure
2) With npt threaded connection and flange
3) Assorts of lengths and diameters
4) Thermo-wells and assembled integrated transmitters are supplied.



Plastic bags and carton box.
Mar-20-12
 
PH-099, designed for simultaneous pH and ORP measurements.
It also reads temperature, which is continuously displayed on the dual level LCD.
It is a waterproof pH, ORP and temperature meter.
All pH readings are automatically temperature compensated(ATC).
Measurements are highly accurate with a unique stability indicator right on the LCD.

The pH electrode, supplied with the meter, is interchangeable and can be easily replaced by the user.
Range : mV 0~1999mV
pH : 0.00 to 14.00 pH
Temperature : 0 to 55
Resolution : mV 1 mV
pH : 0.01 pH
Temperature : 0.1
Accuracy : mV 5mV
pH : 0.1 pH
Temperature : 1
Temperature Compensation : 0 to 50
Electrode : replaceable pH electrode (included);fixed ORP sensor
Power Supply : 4 x 1.5V(AG13)
Environment : 0 to 50
Dimensions : 170 x 40 x 23 mm
Weight : 100 g.
Mar-19-12
 
Thermocouples are manufactured in many different configurations for multitude of applications. Diameters, lengths, sheath material, lead lengths and sensor material are just a few of the variables that go into determining the style of thermocouple when manufactured. The main determining factors of what type thermocouple needs to be used in a application is temperature, environment, response time and accuracy. The junction of the thermocouple can be grounded, ungrounded or exposed. The thermocouple junction may be of many different styles, from tube type to a washer configuration. The lead length may vary depending on the distance of the temperature controller from the thermocouple sensor. The metal that the sensor is constructed of determines the type of thermocouple manufactured.

Applications:
Plastic injection molding machinery
Food processing equipment
Engine and turbine exhaust gas
Semiconductor processing
Heat treating and metals processing
Medical equipment
Aerospace industries
Packaging equipment
Test stands

Features:
Thermocouple Wires: Cromel-Alumel, Iron- Constant, Copper-Constant, imported Bright & Oxidized finish, SWG 10 to 36. PT/PTRH 10%, 13% .
Thermocouple Extension & Compensating Cables: Fiber glass covered, PVC / PVC. Asbestos / Asbestosis, Teflon/Teflon, Insulated, Teflon/Fg/SS Braided single pair, multi pair, Type K, J, T, R, and PT-100 RTD Cables 2 core, 3 core, 4 core , 6 core, Also Teflon /silicon rubber Teflon/shielded/Teflon etc qualities.
Thermocouple M.I. Cables: SS 316, 310 & Inconel 600 quality type K, J, Simplex 1mm,1.5mm, Simplex & Duplex 3mm,6mm, 8mm, also PT-100 RTD Thermocouple M I Cables SS 316 quality. 3mm, 5mm, 6mm 4 core
Thermocouple Assemblies: Straight, L Type , Rotating type, Inmelt Bolt type, Pencil type, Washer, Holder with Spring. Rotating Type, Adjustable Types etc. Made out of SS tube 4.8mm, 6mm,supplied with Spring & Brass bayonets Single Slot & Double Slot , 10mm id, 12mm id, 14mm id, etc.
Thermocouple Brass Parts: ADAPTORS 1/8 BSP, 1/4 BSP, 1/2 BSP, 3/8 BSP Single Pin, Double pin Bayonets.


Wooden box/carton.
Feb-23-12
 
1 RFT8100 wireless temperature and humidity detection system

is composed by wireless temperature detection probes, humidity detection probes and display terminals. Adopting the advanced wireless temperature detection technology, RFT8100 transmits and displays the real time value detected from the local detection probes for the purpose of inspecting temperature and humidity on-site routinely. The alarm relay sends out signal when the temperature and humidity data exceeds or lowers the setting alarm value, and the alarm points can be found quickly by checking the alarm information. RFT8100 also provides curve diagram for checking temperature and humidity variation in short period for equipments management purpose. RFT8100 can achieve the remote monitoring function by transmitting the measured data to DCS monitor centre or equipments management centre thru RS-485 port or Ethernet port.


2 EMC and safety standard

IEC61000-4-2 (GB/T17626.2)
IEC61000-4-8 (GB/T17626.8)
IEC61000-4-4 (GB/T17626.4)
IEC61010-1 (GB/T4793.1).



Exterior Size:91*91*72mm
0.5KGS.
Dec-06-11
 
1.Large LCD screen with blue backlight
2.Setting Temperature Range: 16-35º C,Room temperature:0-50º C
3.Wiring box: 86mm*86mm
4.High grade electronic accessory
5.TX-1008 remote controller is optional(Price is differ)
6.Temperature precision:1º C
7.Locked by remote controller is optional
8.Electric parameter: AC220V±10% 50/60Hz.
2127 Temperature Controllers Indicators Suppliers
Short on time? Let Temperature Controllers Indicators sellers contact you.
Dec-06-11
 
1.Temperature setpoint:16º C-35º C.room temperature: 0º C-50º C
2.LCD light screen shows the running condition of valve
3.Sleeping function
4.Manual alternate of cool or heat
5.Automatically adjust the wind speed
6.Set output delay time about 0-10 minutes
7.Advanced microcomputer control wafer
8.room temperature control precision 1º C.
9.Shell Material: White ABS flameproof plastic
10.Electric parameter: AC110/220V±10% 50/60Hz
11.Two-line, three-line motorized valve
12.Two-pipe, Four-pipe cooling and heating system.
Dec-06-11
 
1. Auto fan
Adjust fan speed automatically according to the temperature
Differential between set value and room temperature
2. Sleeping mode
Adjust the setting temperature automatically according to the
Thermal environmental conditions.
3. Shortcut menu
Enter into the pre-setting temperature directly
4. Key-lock function
To avoid erroneous operations
5. Timer off function
To deactivate the thermostat at your pre-setting time
6. Timer on function
To activate the thermostat at your pre-setting time
7. On/off key
Zero power consumption after switching off
8. Back light(Optional)
Display with backlight, stay on for 15seconds
9. LCD display
Inclined larger size LCD display for better read out
10. Sensor calibration
To ensure accurate temperature measurement
11. Setting min. /max. Allowed temperature
12. Valve indicator
13. Alternate from Cooling/heating by manual
14.18months Guarantee, ISO9001, CE, FCC.
Oct-17-11
 
• Universal PC programmable (PCP)
• 2 wire technology, 4 to 20 mA analogue output
• High accuracy in total ambient temperature range
• Configuration during measurement using configuration kit
• Customer specific measurement range setting
• Wide measurement range, according to requirement
Field of application
• PC programmable (PCP) Temperature head transmitter for converting the input signal into a standard 4 to 20 mA analog output signal
• Input: Resistance thermometer (RTD) Pt100
• Configuration using a PC with MS180 configuration kit (MS180-PC).



Appearance and Size (in mm)

NOTE: When order, please specify the measuring range, we’ll offer programming tool if needed.
Oct-17-11
 
MS181 is an intelligent temperature transmitter module which can be programmed through a PC with Configuration Kit. It has measurement input for resistance thermometers (RTD) ,thermocouples, resistances or millivolt signals in 2-,3- or 4-wire connection, and converts various input signals into a 4~ 20mA analog output signal after linear processing. Isolation is provided between the input and output. A special signal can be set in advance while the sensor burnout or short.
Primary Technical Characteristics
Programmable Use the MS181 programming tool
Measuring range Set via PC
PC Interface USB/RS232
Input type RTD, TC, R or Millivolt signal
Convert accuracy ¡Ü0.1£¥FS
Cold junction accuracy ¡À1(TC)
Output 4¡«20mA/20¡«4mA Electrical isolation output
Max-load £¨V -8V£©/0.025A£¨Current output £©
Limit current ¡Ü25mA
Response time 1s
Isolated voltage 1500V AC (input/output)
Alarm signal Programmable
Underranging linear drop to 3.8 mA
Overranging linear rise to 20.5 mA
Sensor break or short-circuit:
¡Ü3.6mA or¡Ý21.0mA
Power supply 8¡«30V DC
Temperature drift 0.01£¥ FS / 1
Long-term stability ¡Ü0.1 per year or 0.05£¥ per year
Ambient -40¡«+85
Oct-17-11
 
MS150 Series multi-channel temperature monitor is a multi-point temperature measurement instrument. It takes the highest measured temperature in measuring loops as its output signal which is sent out in the form of a 4 to 20 mA standard current signal and the temperature is displayed by the built-in LED. If required, temperature at any measuring point can be shown by operating the keys on panel. Isolation is provided between the input and output.
It is mainly used in the applications of multi-point temperature measurement or alarm warning system. By adopting SMT technology, it offers excellent accuracy, reliability and anti-disturbance.
Primary Technical Characteristics
Measuring range 0¡«100¡æ¡¢0¡«150¡æ¡¢0¡«200¡æ
£¨according to user's demand£©
Input type Pt100,Cu50£¨TC if specially required£©
Measuring Points 2,3,4,5,6 points
Convert accuracy ¡Ü0.5£¥FS
linearity error < 0.1%
Output 4¡«20mA Electrical isolation output
Digital display LED
Display accuracy 0.5%
Voltage drop for display 3V
Isolated voltage Drop 2V
Isolate Voltage 1500V AC (Input/Output¡¢with isolator)
Max-load £¨V -14V~16V£©/0.025A£¨Current output £©
Limit current ¡Ü25mA
Response time 1s
Power supply 14~30V DC
Temperature draft 0.025% FS/ 1¡æ
Long-term stability ¡Ü0.1¡æper year or 0.05£¥ per year
Ambient -40~+85¡æ£¨Aluminium alloy .Casing£©
-25 ~+75¡æ£¨Plastic Casing£©
Protection level IP66£¨Aluminium alloy£©/IP62£¨Plastic£©
Anti-RFI >10v/m(80MHz¡­¡­1000MHz).
Oct-17-11
 
MS182 is a smart in-head transmitter module with HART® -protocol. It has measurement input for resistance Thermometers (RTD), thermocouples, resistance or millivolt signals in 2-, 3- or 4-wire connection, and converts various input signals into a standard 4 to 20 mA analog output signal after linear processing. The transmitter is programmable directly from PC or via the HART communication. Isolation is provided between the input and output. A special signal can be set in advance while the sensor burnout or short.
Primary Technical Characteristics
Programmable Use PC or the hand operator
Measuring range Set via PC or by the hand operator
Input type RTD, TC, R or Millivolt signal
Convert accuracy 0.1£¥FS
Cold junction accuracy ¡À1(TC)
Output 4¡«20mA/20¡«4mA Electrical isolation output
HART ¨CProtocol output
Max-load £¨V -13V£©/0.025A£¨Current output £©
Limit current 25mA
Response time 1s
Isolated voltage 1500V AC (input/output)
Alarm signal Programmable
Underranging linear drop to 3.8 mA
Overranging linear rise to 20.5 mA
Sensor break or short-circuit:
3.6mA or ¡Ý21.0mA
Power supply 13¡«30V DC
Temperature drift 0.01£¥ FS/1
Long-term stability 0.1 per year or 0.05 £¥per year
Ambient -40¡«+85.
Oct-17-11
 
MS183 , a smart 2-wire in-head and dual-input transmitter module with HART® -protocol, has measurement input for resistance Thermometers (RTD), thermocouples, resistance or millivolt signals in 2-, 3- or 4-wire connection and converts various input signals into a standard 4 to 20 mA analog(high selector, average value or D-value) output signal or 2-way digtal output signals with HART® -protocol after linear processing. The transmitter is programmable directly from PC or via the HART communication. Isolation also is provided between the input and output. A special signal can be set in advance while the sensor burnout or short.
Primary Technical Characteristics
Programmable Use PC or the hand operator
Measuring range Set via PC or by the hand operator
Input type Dual-input ( RTD, TC, R or Millivolt signal)
Convert accuracy ¡Ü0.1£¥FS
Cold junction accuracy ¡À1¡æ(TC)
Output 4¡«20mA/20¡«4mA Electrical isolation output
HART ¨CProtocol output (2-way)
Max-load £¨V -16V£©/0.025A£¨Current output £©
Limit current ¡Ü25mA
Response time 1s
Isolated voltage 1500VAC (input/output)
Alarm signal Programmable
Underranging linear drop to 3.8 mA
Overranging linear rise to 20.5 mA
Sensor break or short-circuit:
¡Ü3.6mA or ¡Ý21.0mA
Automatic switching while sensor damaged
Power supply 16¡«30V DC
Temperature drift 0.01£¥ FS/1¡æ
Long-term stability ¡Ü0.1¡æ per year or 0.05 £¥per year.
Jul-16-11
 
SSR, 0-10v- P, PI, PD, PID Or ON/OFF Hysteresis Control, Selectable Sensor Input (J type (Fe-Const), K type (NiCr-Ni), Pt100, R type (PtRh13Pt), S type (PtRh10Pt), T type (Cu-Const) ).
Feb-14-11
 
The controller is designed for aquarium controlling.It process is directly and efficiently perceived through the senses.The autocontrol including temperature, pump an lights.The customer setting can be remembered when the power shut down.For the physical desigh, we seperate the high voltage circuit from the controlling circuit.This is safe for the operating personnel.The power board print every output name , such as light, uv, .Etc.The controller is necessary for aquarium.



CARTONS
Mar-01-11
 
Cooling and heating controller.
Jan-11-11
 
Fan controllers
Light control / baybus
Front i/o adapters
Temperature sensors
Configurable lcd displays
Fan speed controller
Manual rpm control
Multi fan controller,
Fan rpm monitoring and control .




Cartons.
Apr-26-11
 
Main function: cooling, heating, ventilation, fresh air, error alarm, 3-grade air-flow adjustment, hold cooling.

Application: KINGTECH,LIUGONG Machinery, XGMA Machinery.
May-11-11
 
Power supply : 12V/24V(DC10V-DC15V)(DC20V-DC30V)
Power consumption : 0.5W
Current : Max.100mA
Input
: 1) Interior temp. sensor (25¡æ,Rb=5K£¬B=3274)
2) A/C power£¨generator£©
Output : 1) Fan grade 3(max. 2A)
2) Fan grade 2(max. 1.5A)
3) Fan grade 1(max. 1A)
4) Clutch signal (max. 1A)
Display : Marked
Ambient temperature : -30¡æ¡ª80¡æ 5£¥£­95£¥RH Non-condensing
Storage temperature : -10¡æ¡ª70¡æ 5£¥£­95£¥RH Non-condensing
Display precision : Dual digit display of set temp., accuracy 1¡æ; dual digit display of inside temp. accuracy 1¡æ
Faceplate level : IP54
EMC level : EN50081&EN50082-2
Security level : Applied to EN61010-II, Pollution degree: II
Weight : 150g.
May-11-11
 
Technical date

Code : NHT06006L01
Power supply : DV24V(DC16V-DC30V)
Power consumption : 3W
Current : BELOW 100mA
Electrical connection : Max.1m X 0.5mm
Direction of rotation : ON/OFF
Angle of rotation : 89¡ã+2¡ã
Torque : 6kgf.cm
Running time : 3.5+0.5rpm
Locked torque : 412kgf.cm
Locked current : Max.50mA
Noise level : Max.43dB(A)
Ambient temperature : -30¡ãc¡ª80¡ãc
Storage temperature : -40¡ãc¡ª85¡ãc
Life : Max.500,000 cycle
Dimensions : 112X57X72(mm)
Weight : 205g
Quality certification : TS16949/ISO9001.
Apr-26-11
 
Main functions: fully-automatic control, cool, heating, ventilation, fresh air, air-flow direction, memory, error alarm, voltage auto-protection, demisting, evaporator fan PWM 7-grade adjustment, LCD display ,attractive appearance.

The shift function
1) Running time check
2) Defrost temp. display (press fresh air button for no less than 3S)
3) Hold cooling (press cooling button for no less than 3S)

Application
YUXIN Automotive Air Conditioner, LIUGONG Machinery, XGM Machinery, JINGONG Machinery, KOBELCO.
2127 Temperature Controllers Indicators Suppliers
Short on time? Let Temperature Controllers Indicators sellers contact you.
See what buyers and suppliers are discussing in Temperature Controllers Indicators import export community