At Tex Mach International, we provide our customers with a wide range of New & Used Solar Energy Systems & Components. As you know very well, the solar panel business is growing rapidly around the world and we are very excited to be in contact with you. Our Panels, Inverters, Batteries, Racking & other components are all collected from around the globe. Which means, they are the panels distributed in by manufacturers, distributors, wholesalers & end users in new & used quality. Please be noted that our stock rate of turnover changes very drastically as we have big buyers all the time.
For Used Solar Components, we do not attach any WARRANTY to our products, as we do not purchase directly from the solar manufacturing companies. Our prices are is in Ex-Works. They are not in FOB nor CIF/ CNF. Shipping charges will be added on top of these component prices.
Autonomous robots that clean solar panels. 2 types - dependent ( long and for huge solar farms )
independent ( Small and for small to medium solar farms )
"Storage tank for sanitary hot water production for domestic or industrial use.
The tanks are available with1,2,3 flanges in order to be able to adapt the
heat exchanger of the desired capacity.
The tanks can be connected with any source of energy, ideal for solar
applications.
The tanks are made of high quality steel, complete with anodic protection,
internal protection of enamel, according to EN/DIN 4753.
The tank is perfectly insulated with soft PU foam of 100mm thickness.
"
Kaltech Energy 300 Liters Solar water heating system
"Thermosiphon is a method of passive heat transfer by natural convection
External cover with 3layers of protection and UV resistance
Perfect aesthetic result
Internal protection with double enamel, heated at 860C, certified by German enamel Federation.
Two magnesium anodes for absolute protection
Special internal design for increased efficiency."
Pumps that works 100% on solar energy
No Electricity saving of 100% on electricity
No Battery
No Controllers
Direct work with solar panel Less maintenance
This type solar water heater has pumps to circulate thermal media, (water, or glycol) to exchange heat from the solar collector to the water storage tank. Solar collectors and storage tanks installed at different locations of the building and the heat transfer happens through high efficiency pumps controlled by microprocessor-based controls.
Tanks can be installed separately from the collector
Possibility to control overheating during summer
Electric backup heater with auto temperature control
Unlimited capacities & suitable for large installations
Remote monitoring & Control options
This type solar water heater has pumps to circulate thermal media, (water, or glycol) to exchange heat from the solar collector to the water storage tank.
Thermal media circulate and collect heat from the collector and transfer to the drain back storage tank. The solar pump activates and heat transfer occurs only when it is required and as a result heating of the water happens in the controlled manner.
As the media drains to the drain back tank from the collector freely, the storage tank always needs installed below the collector and the interconnecting pipes must have slope.
Tanks can be installed separately from the collector
No overheating
Electric backup heater with auto temperature control
Remote monitoring & Control options
Drain Back Solar Water Heater
Drain back systems are closed-loop, indirect, active solar water heating systems. Glycol-water or mix of both will act as heat transfer media. The heat transfer media contained in an unpressurized, closed loop is pumped through the collectors. The media will transfer heat to the domestic water through a heat exchanger.
Various ratings
Thermostat control attached
Made in Europe
Technical characteristics
Type Three phase with various power rating
Temperature RANGE0 to 100°C
CONTROLAttached The
Technical characteristics
TYPEThree phase with various power rating
Temperature RANGE0 to 100°C
Control Attached Thermostat
Rating7.5KW/10KW/12KW/15KW
Operation
The differential expansion of the sensing element causes the opening of a snap-action switch in the thermostat head. In case of abnormal temperature rise, a bimetal disc ensures double pole safety. The limiter is manually re-settable.
Technical characteristics
Type Single pole stem control with single pole bimetal safety limiter
Temperature Range0 to 160°C
SAFETY LIMITER TEMPERATUREFixed 70 to 120°C
Rating15a – 400V / 20A – 250V
MATERIALBrass, invar, bimetal
Stem Lengthup to 450 mm
Connections Brass faston or screw terminals
Approvals CE conformity, ENEC mark according to EN 60730-1, EN 60730-2-9, ROHS conformity
Independent non self resetting safety function
Over temperature cut out
Available with single pole limiter or as control only
Factory pre-set fixed temperature limiter
End-user adjustable control temperature
Relay activity
Maximum store temperature exceeded
Antifreeze function active
Sensor fault
Manual mode
Normal operation
Indication of the buttons available in the menu item
8179 Solar Power Equipments Suppliers
Short on time? Let Solar Power Equipments sellers contact you.