Glazing glass is a combination of two or more pieces of glass spaced apart with a spacer bar and hermetically sealed with a primary and secondary sealant to form a single unit with one or more air spaces between each other.
Max size :3300*12000mm
Main character :
Energy saving , improving the thermal performance
Sound insulated
Security and comfort
Component :
1.� Glass items:� consists of hard or soft low E glass ,reflective glass ,clear glass ,tinted glass, with types of flat tempered ,bent ,laminated processing ,according to the application
2.� Spacer bar :is the material used to separate the two glass lites in an IGU. It can be made by aluminum,stainless steel,hybrid ,plastic material .
Stainless steel cut wire shot with a bright surface that is used for shot blasting, shot peering and deburring in non-ferrous metal and stainless steel products surface. The surface of work-pieces are smooth, no rust and highlight metallic luster after process.
Ultra-sharp, tri-bevelled, anti-coring needle;
Stainless steel cannula;
Metal insert increases needle strength for animal health applications;
Coated with a Silicons Polymer;
Sterile;
Two pieces rigid pack;
Cartridges are color-coded to follow industry standards providing easy gauge Identification
Refer Standards
EN ISO 8537:2007 Sterile single-use syringes, with or without needle, for insulin.
EN ISO 9626:1991 / AMD. 1: 2001 Stainless steel needle tubing for the manufacture of medical devices AMENDMENT 1.
ASTM F88/F88M-09 Standard Test Method for Seal Strength of Flexible Barrier Materials.
ASTM F1140/F1140M -13 Standard Test Methods for Internal Pressurization Failure Resistance of Unrestrained Packages.
ISO 10993-7:2008 Biological evaluation of medical devices - Part 7: Ethylene oxide sterilization residuals.
USP 37- NF32 2014: U.S. Pharmacopeia National Formulary.
Refer Standards
ISO 9626: 1991 + AMENDMENT 1 2001 Stainless steel needle tubing for the manufacture of medical devices.
ISO 8537:2007 Sterile single-use syringes, with or without needle, for insulin.
ISO 10993-7:2008 Biological evaluation of medical devices - Part 7 : Ethylene oxide sterilization residuals.
ASTM F 1140/F 1140M-13 Standard test methods for internal pressurization failure resistance of unrestrained packages.
USP 37-NF 32 <85> Bacterial Endotoxins Limit.
ISO 11737-2:2009 Sterilization of medical devices - Microbiological methods - Part 2: Test of sterility performed in the definition, validation and maintenance of a sterilization process.
ISO 11135-1:2007 Sterilization of health care products - Ethylene oxide - Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices.
Features and Benefits
Sterile pack, single use only.
Needle-stick prevention, safety assured.
Special needle tip design to prevent rubber fragment contamination.
Luer connector, equipped with needleless connector, heparin cap, Y three-way.
Chassis sponge design for a more comfortable application.
High pressure resistant central line with 325 P.S.I
Two holes connector optional.
MDR 2017/745
USA FDA 510K
Refer Standards
ISO 10555-6:2015 Intravascular catheters - Sterile and single-use catheters Part 6: Subcutaneous implanted ports.
ISO 8536-4: 2010 Infusion equipment medical use- Part 4: Infusion Sets for single use, gravity feed.
ISO 23908:2011 Sharps injury protection Requirements and test methods - Sharps protection features for single-use hypodermic needles, introducers for catheters and needles used for blood Samplings.
ISO 7864:2016 Sterile Hypodemic Needles for Single-use requirements and test methods.
ISO 9626:2016 Stainless Steel Needle Tubing for the Manufacture of Medical Devices requirements and Test methods.
ISO 80369-7: 2016 Small - bore connectors for liquids and gases in healthcare applications.
Part 7: Connectors for intravascular or hypodermic applications.
ISO 10993-7:2008 Biological Evaluation of Medical Device - Part 7: Ethylene Oxide Sterilization Residuals.
Light rail is the nominal weight less than or equal to 30 kg per meter of the rail. Light rail, the low proportion of the quality requirements of rail requires only test its chemical composition, tensile strength, hardness and drop test, etc
Light rails(steel rails), the main products of our company are heavy rails of 38kgs/m, 43kgs/m, 50kgs/m, material is u71mn/u71. Standard is gb2585-2007, q/yyg002-2008.Length is 12m, 12.5m
Crane rails of qu70, qu80, qu100, qu120, material is u71mn, standard is yb/t5055-93.Length is 12m, 12.5m
I-beam of mine usage steel of 9, 11, 12, material is 20mnk/q235.Standard is yb/t5047-2000.Length is 8m, 9m, 10m
U-beam of the mine steel channel of 25u, 29u, 36u, material is 20mnk/q275. Standard is gb4697-1997, q/yyg006-2008, gb4697-1991.Length is 8m, 9m, 10m, 12m
Fish plate of 8kgs, 12kgs, 15kgs, 18kgs, 22kgs, 24kgs, 30kgs, 38kgs, 43kgs/m, material is q235b.Standard is gb11265-89, gb185-63. Length is 45.5cm, 53.54cm, 61.73cm, 71.48cm, 79cm
Introduction:
Product description
1. Choosing the optimal grinding media - we can help you choose the correct media for your application based on ore characteristics and your mill
2. Improved production and energy efficiency - our tools allow us to identify the correct media and mill liner pairing
3. Lower total cost of ownership - the correct media choice coupled with our exact manufacturing maximizes wear life
4.Continuous improvement - our sophisticated monitoring tools coupled with wear performance simulation means we can continue helping optimize production
Product name:forged grinding ball/casting steel ball/hot rolling grinding media balls for ball mills
Material:b2, b3, b6, bu 45steel, high chrome, low chrome steel
Surface hardness:hrc58-65
Volume hardness:hrc56-63
Impact toughness:18j/cm2
Breakage rate:less than 0.5%
Annual out out:200, 000 tons
Application:mines/cement plants/power stations/chemical industry, mines/cement plants/power stations/chemical industry