TKBLQ-I zinc oxide arrester tester is a special instrument used to test the electrical performance of arresters. The instrument is suitable for live or power failure detection of arresters of various voltage levels, so as to timely detect the internal insulation damp and valve aging and other dangerous defects.
TKBLQ-I zinc oxide arrester test instrument is easy to operate and easy to use. The whole measuring process is controlled by microcomputer. It can measure the total current, resistive current and its harmonics, power frequency reference voltage and its harmonics, active power and phase difference. The real waveform of voltage and current can be displayed on the large screen.
Features:
1. 5.7 "320 Ã?? 240 LCD, high-speed thermal printer; graphic display, intuitive interface, easy to operate and use.
2. It is applicable to live arrester, power failure or laboratory.
3. The current and voltage sensors are completely isolated, safe and reliable. A, B, C three-phase arrester can be stored as a group of test data.
4. The instrument can test continuously, display voltage current curve, and print data and curve quickly.
5. The internal configuration memory can store 200 groups of test data when power down.
6. With RS232 communication interface, the test data can be exported through the upper computer.
7. High speed sampling frequency, advanced digital signal processing technology, strong anti-interference performance, high accuracy of measurement results.
8. It adopts dustproof, waterproof and anticorrosive engineering plastic sealing box, which is small in volume, light in weight and easy to carry.
TKBLQ-II zinc oxide arrester tester is a special instrument used to test the electrical performance of zinc oxide arrester. The instrument is suitable for live or power failure detection of zinc oxide arrester of various voltage levels so as to timely detect the internal insulation damp and valve aging and other dangerous defects.
TKBLQ-II zinc oxide arrester tester is easy to operate and easy to use. The whole measuring process is controlled by single chip microcomputer. It can measure the total current resistive current and its harmonics power frequency reference voltage and its harmonics active power and phase difference. The instrument uses digital waveform analysis technology harmonic analysis and digital filtering software anti-interference methods to make the measurement results accurate and stable.
1. This machine adopts large screen LCD display all English menu operation easy to use.
2. High precision sampling and processing circuit and advanced Fourier harmonic analysis technology ensure more reliable data.
3. The instrument adopts high-speed magnetic isolation digital sensor to directly collect the input voltage and current signals which ensures the reliability and safety of the data.
4. Support wireless synchronous voltage sampling mode (type II).
5. The instrument can use electric field induction instead of PT secondary wiring (type I).
6. It has the functions of resistive current fundamental peak output and side phase correction.
7. The instrument is equipped with rechargeable battery calendar clock and micro printer which can store 120 sets of measurement data.
This Tester is used to verify the electrical performance of Zinc Oxide Arrester. The instrument is suitable for various kinds of voltage levels zinc oxide arrester de-energized testing or energized testing thus define the risk and inner insulation moisture and valve aging defects.
1. 800 Ã?? 480 color LCD touch screen and high speed thermal printer.
2. Long distance wireless transmission. PT signal wireless transmission distance more than 400 m up to 2000 m;
3. Applicable for arrester de-energized test energized test and lab room test.
4. Three-phase current and three-phase voltage test simultaneously current and voltage sensor is isolated safe and reliable.
5. Two signal sampling methods support no voltage mode software calculation to get voltage reference
6. Built in high energy lithium battery And only weak current inside the instrument voltage is less than 12 volts.
7. Equipped with industrial grade operating system support direct shun-down mode
8. With 4G SD card can store massive testing data
9. With USB interface
10. Advanced data processing system support historical data management data analysis report automatic generation&printing
11. High sampling rate advanced digital signal processing technology high anti-interference performance and high precision.
12. With dust-proof waterproof anti-corrosion engineering seal box package small volume light weight and portable.
1. Standard 4-phase voltage and 3-phase current output with 4-phase voltage and 3-phase current output can conveniently carry out various combination outputs for various types of protection tests. Single-phase voltage can output up to 120V single-phase current up to 40A (10 seconds) current three and can output up to 120A the fourth phase voltage Ux is a multi-function voltage item can be set as 4 kinds of 3U0 or check the same period voltage or a certain voltage value of the case output.
2. Single machine is easy to operate. The single machine is operated by a convenient and flexible rotating mouse through a large LCD screen all of which are displayed in Chinese. It can complete most of the field test verification work can verify all kinds of relays and microcomputer protection and can simulate all kinds of complex transient permanent and transformational faults for the whole group of tests. Boot can be used easy to operate.
3. Double operation mode connected to the computer operation through the Windows platform of the full set of Chinese operating software can carry out a variety of large complex and higher degree of automation verification work can be easily tested and scanned a variety of protection fixed value can be real-time storage test data display vector diagram draw fault waveform online print report etc.
4. Software is so powerful that can complete all kinds of high degree of automation of large complex check work such as three phase differential test auxiliary power fast cutting prepared from the cast test line protection inspection period reclosing etc. can easily test and scanning protection setting various fault playback real-time storage test data show that the vector diagram online printing report etc.
5. Switch quantity contact is rich three - phase for 7 contact input and 2 pairs of empty contact output. The input contacts are compatible with 0 ~ 250V potential contacts and can be identified automatically. Input and output contacts can be expanded according to user needs.
6. Large screen LCD display microcomputer relay protection tester adopts 320Ã??240 lattice large screen high-resolution graphics LCD display all the operation process are set on the display screen the operation interface and test results are displayed in Chinese the display is intuitive and clear.
7. Self-protection adopt reasonable design of heat dissipation structure and have a variety of reliable and perfect protection measures and power soft start and a certain fault self-diagnosis and locking function.
8. With an independent dedicated dc power output the device is equipped with one 110V and 220V dedicated dc power output.
9. High cost performance belongs to the cross - professional joint design products integrated multi - professional advanced scientific and technological achievements. Both large tester performance and small tester price with a high performance ratio.
TKJB SINGLE PHASE RELAY TEST SET is a portable field testing equipment with excellent performance; Elegance and polished appearance with aluminum alloy chassis and PC panel, within the ARM chip control, LCD screen display voltage and current output stopwatch, it could output a full isolation way for adjustable AC/DC voltage, and AC/DC current and a way for adjustable DC voltage; the output loop with double overload protection with large output capacity ,small volume, light weight, high reliability ,It Suitable for field calibration and test for various relay.
Product Characteristics
Single Phase Relay Test Set Main Features
1 Output a full isolation way for adjustable DC voltage, Automatic protection for short circuit, overload and out range.
2 Maximum Output Current:0150A
3 Equipped with LCD digital AC/DC volt-ampere meter, can show the AC and DC voltage and current values, stopwatch, potential, contact state.
4 Internal electric stopwatch; Available electrical contacts, maximum potential 250V; Dual channel measurement.
5 Light-weight design, small-volume, and fully-functional.
845 Electronics Communications Suppliers
Short on time? Let Electronics Communications sellers contact you.
TKRJ- electronic thermal relay calibration is mainly used for setting and calibration of various thermal relays and motor protection devices. Because of its reasonable design convenient operation and high output power it is widely used in electric test sites of power system railway petrochemical metallurgical and mining enterprises.
1. It can output three-phase 0-500a current at the same time.
2. It can synchronously test the action time of thermal relay thermocouple and motor protector.
3. Normally open and normally closed contact detection.
4. Several calibrations can be connected in series at the same time to improve working efficiency.
3. Power electronics controlling technique has been adopted to output high current with high speed high precision and continuous adjustability.
4. Current range can be automatically switched by multiple high precision sensors.14 digit AD acquisition chip of high capacity.
5. Automatic data storage. Be capable of saving 200 testing results which will not lose in power failure.
6. Two options: ampere-second characteristic test or through current characteristic test.
7. When linking to PC it is available to do following operations such as controlling the instrument data importing data saving data report and data graph generation.
8. Protection functions for overheat over-current and over voltage.
9. Anti-interference capacity and good EMC(electromagnetic compatibility).
Product Introduction
With the development of society people have higher and higher requirements for the safety and reliability of power consumption. High-voltage circuit breakers have the dual tasks of control and protection in the power system. The performance of the power circuit is directly related to the safe operation of the power system. The mechanical characteristic parameter is one of the important parameters for judging the performance of the circuit breaker.
The Breaker Analyzer is a special instrument developed by the company to meet the needs of various high-voltage switch operating characteristics tests. It can accurately measure low-oil multi-oil vacuum sulfur hexafluoride and other high-voltage circuit breakers of various voltage levels. Mechanical dynamic characteristics parameters. The instrument adopts large screen display Chinese characters prompt man-machine dialogue mode operation Chinese characters display results and printouts with intelligent multi-function accurate data strong anti-interference simple operation small size light weight and beautiful beauty.
Product nickname High voltage switch mechanical characteristic tester High voltage switch comprehensive tester Circuit breaker dynamic characteristic tester Circuit breaker mechanical characteristic tester Circuit breaker comprehensive tester High voltage switch time characteristic tester High voltage switch characteristic tester Switching characteristic tester Breaker Analyzer Switch parameter tester
With the development of society people have higher and higher requirements for the safety and reliability of power consumption. High-voltage circuit breakers have the dual tasks of control and protection in the power system. The performance of the power circuit is directly related to the power system. Safe operation mechanical characteristic parameters are one of the important parameters to judge the performance of the circuit breaker.
Breaker Analyzer is a special instrument developed by the company to meet the needs of various high-voltage switch operating characteristics tests. It can accurately measure low-oil multi-oil vacuum sulfur hexafluoride and other high-voltage circuit breakers of various voltage levels. Mechanical dynamic characteristics parameters. Its main feature is that in addition to meeting the dynamic characteristics test of the general high-voltage switch on the market it also satisfies the test of Siemens graphite contact switch and can reliably test the dynamic resistance waveform of the three fractures of the graphite contact switch. The instrument adopts large screen display Chinese characters prompt man-machine dialogue mode operation Chinese characters display results and printouts with intelligent multi-function accurate data strong anti-interference simple operation small size light weight and beautiful beauty.
With the development of society people have higher and higher requirements for the safety and reliability of power consumption. High-voltage circuit breakers have the dual tasks of control and protection in the power system. The performance of the power circuit is directly related to the safe operation of the power system. The mechanical characteristic parameter is one of the important parameters for judging the performance of the circuit breaker.
The Breaker Analyzer is a special instrument developed by the company to meet the needs of various high-voltage switch operating characteristics tests. It can accurately measure low-oil multi-oil vacuum sulfur hexafluoride and other high-voltage circuit breakers of various voltage levels. Mechanical dynamic characteristics parameters. For circuit breakers with closing resistors the closing resistor and switching waveform can be accurately measured. The instrument adopts large screen display Chinese characters prompt man-machine dialogue mode operation Chinese characters display results and printouts with intelligent multi-function accurate data strong anti-interference simple operation small size light weight and beautiful beauty.
With the development of society people have higher and higher requirements for the safety and reliability of power consumption. High-voltage circuit breakers have the dual tasks of control and protection in the power system. The performance of the power circuit is directly related to the safe operation of the power system. The mechanical characteristic parameter is one of the important parameters for judging the performance of the circuit breaker.
The Breaker Analyzer is a special instrument developed by the company to meet the needs of various high-voltage switch operating characteristics tests. It can accurately measure low-oil multi-oil vacuum sulfur hexafluoride and other high-voltage circuit breakers of various voltage levels. Mechanical dynamic characteristics parameters. The instrument adopts large screen display Chinese characters prompt man-machine dialogue mode operation Chinese characters display results and printouts with intelligent multi-function accurate data strong anti-interference simple operation small size light weight and beautiful beauty.
Product nickname High voltage switch mechanical characteristic tester Switch mechanical characteristic tester High voltage switch comprehensive tester Circuit breaker dynamic characteristic tester Circuit breaker mechanical characteristic tester Circuit breaker comprehensive tester High voltage switch time characteristic tester High voltage switch characteristic tester Switching characteristic tester Breaker Analyzer Switch parameter tester
Product Introduction
With the development of society people have higher and higher requirements for the safety and reliability of power consumption. High-voltage circuit breakers have the dual tasks of control and protection in the power system. The performance of the power circuit is directly related to the safe operation of the power system. The mechanical characteristic parameter is one of the important parameters for judging the performance of the circuit breaker.
The Breaker Analyzer is a special instrument developed by the company to meet the needs of various high-voltage switch operating characteristics tests. It can accurately measure low-oil multi-oil vacuum sulfur hexafluoride and other high-voltage circuit breakers of various voltage levels. Mechanical dynamic characteristics parameters. The instrument adopts large screen display Chinese characters prompt man-machine dialogue mode operation Chinese characters display results and printouts with intelligent multi-function accurate data strong anti-interference simple operation small size light weight and beautiful beauty.
Product nickname High voltage switch mechanical characteristic tester High voltage switch comprehensive tester Circuit breaker dynamic characteristic tester Circuit breaker mechanical characteristic tester Circuit breaker comprehensive tester High voltage switch time characteristic tester High voltage switch characteristic tester Switching characteristic tester Breaker Analyzer Switch parameter tester
Transformer winding deformation test instrument based on the measurement of the characteristic parameters of transformer internal winding the internal fault frequency response analysis (FRA) method which is being developed in developed countries is adopted to make an accurate judgment of transformer internal fault.
After the design and manufacture of transformer is completed the line coil and internal structure are determined. Therefore for a multi-winding transformer line coil if the voltage grade is the same and the winding method is the same the corresponding parameters (Ci Li) of each line coil should be determined. Therefore the frequency domain characteristic response of each line coil is determined accordingly and the frequency spectrum of the corresponding three-phase line coil is comparable to some extent.
The distribution parameters of transformer windings will change when short-circuit between turns and phases occurs in the test process or collision occurs in the transportation process resulting in the relative displacement of the line coil and the deformation of the line coil caused by electromagnetic tension in the short-circuit and fault state during the operation process. Then it influences and changes the original frequency domain characteristics of the transformer that is amplitude change of frequency response and resonance frequency offset. The transformer winding test instrument developed according to the response analysis method is such a novel non-destructive testing equipment for transformer internal faults. It is suitable for the internal structure fault detection of 63kV ~ 500kV power transformer.
product names Electric power transformer winding deformation test instrument Transformer winding deformation detector Transformer winding deformation meterTransformer winding deformation analyzer
Product Introduction
This product is specially used for measuring the capacity of distribution power transformer measuring the no-load and short-circuit loss of transformer and has the function of harmonic analysis which is convenient for analyzing the quality of on-site power network. The device can automatically check whether the wiring is correct and display the vector diagram of the three-phase current and voltage when testing the three-phase transformer. At the same time necessary correction (such as waveform correction temperature correction unrated voltage correction calibration unrated current correction) is introduced to make the test results more accurate.
Product name Transformer capacity test instrument transformer capacity load tester
Dc resistancetest around group is an indispensable test project of transformer after the submission of pick up overhaul and change of subpick up switch. In general using traditional methods (bridge method and pressure drop method) measurement transformer winding group and dc resistance of large power inductance equipment is a time-consuming and time-consuming work. In order to change this situation shorten measurement time and reduce work burden of test personnel, our company developed Dc resistance rapid test instrument (hereinafter referred to as direct resistance instrument). It adopts new power supply technology featuring stable performance rapid measurement small size easy to use high measurement precision and good data repeatability. Measurement transformer is around the group and large power inductor dc resistance ideal equipment
product names Dc resistance tachometer Transformer dc resistance test instrument. Transformer winding dc resistance test instrument. Transformer direct resistance speed meter Transformer direct resistance quick test instrument Inductive load Dc resistance tachometer Inductive load dc resistance rapid test instrument Inductive load dc resistance test instrument Dc resistance tester
TKBB-S Transformer Ratio Tester is specially designed for three- phase transformer in power system especially for transformer of type Z winding and other transformers whose zero-load current is relatively high.Transformer turns ratio test is very important in order to find out the transformer has the right ratio corresponding on its rated voltage in primary and secondary. TKBB-S is single phase, automatically test set specially designed for turns ratio, phase shift and excitation current measurements of power, distribution and instrument transformer.
The on-load tap changer is the only moving part connected with the transformer circuit so more and more attention has been paid to the detection of the on-load tap changer.In the electrical equipment handover and preventive test regulations it is required to check the action sequence of on-load tap changer measure switching time etc.This device is mainly used for measuring the transition waveform transition time transient resistance of transformer on-load tap changer three-phase synchronism etc.
Impulse voltage generator is mainly used for impulse voltage test of power equipment such as lightning impulse voltage full wave lightning impulse voltage truncation wave and operating impulse voltage wave to test insulation performance.Impulse voltage generator a power supply device that imitates impulse voltages such as lightning and operating overvoltages.It is mainly used in insulation shock withstand voltage and dielectric shock breakdown and discharge tests.
Scope of application: standard lightning shock lightning cut-off wave for transformers reactors mutual transformers and other high voltage electrical appliances high voltage thyristor valve SVC(HVDC) power cables all kinds of high voltage insulators bushing operation shock and all kinds of non-standard shock wave impulse voltage test required by users.Various test waveforms (standard and non-standard waveforms user-generated waveforms) can be generated by a single set of equipment.Field of application: lightning protection and lightning test for quality inspection measurement inspection and supervision organizations power equipment manufacturers railway communications aerospace and aerospace vehicles military research units universities and meteorological departments.
900kV/67.6 kJ Lightning Impulse Voltage Generator Complete Test Equipment for Transformer Reactor Cable
VLF (Very Low Frequency) Testers are suitable for testing power cables transformers switchgear rotating machinery and other electrical apparatus.
1. Data of current voltage wave form can be directly sampled at high voltage side so the data is real and accurate.
2. Overvoltage protection: If the output exceeds the set limit of voltage the instrument will shut-down to protect itself the actuation time is less than 20ms.
3. Overcurrent protection: It is high-low voltage dual protection in the design the accurate shut-down protection can be made according to the set value at high voltage side; If the current on low voltage side exceeds the rated current the instrument will take shut-down protection the actuation time are both less than 20ms.
4. A high voltage output protective resistor is provided in the voltage boost body in the design and this eliminates the need of additional protect
845 Electronics Communications Suppliers
Short on time? Let Electronics Communications sellers contact you.