The 640 addressable audio/visual alarm devices are suitable for connection to 2-wire addressable fire detection
And alarm systems.
640 is loop-powered and activation is initiated by a dedicated initiation message from the control and indicating
Equipment. Up to 125 devices can be connected to each alarm zone loop.
Visual, audible and audio/visual models available
Red or white body available for audible alarm device
Loop-powered from control and indicating equipment
Operates when a dedicated activation message is received from the control and indicating equipment
Loud sounder output of 85 db at 1 m
Long-life leds
Low quiescent current
Dip switch address setting
Oct-20-16
 
Snd-500 dc smoke alarms provide battery powered smoke detection and alarm functions within a single unit.
Advanced electronics in conjunction with a photoelectric smoke sensing chamber provide early detection of fire
And high immunity against unwanted alarms.
Snd-500 dc smoke alarms are battery powered, do not require a mains supply, and are suitable for general
Residential applications.
Photoelectric smoke sensor
Integrated indicator provides visual indication of an alarm condition
Test button verifies battery and alarm operation
Loud 85 db sounder to alert occupants
Single dc 9 v user-replaceable battery provides up to 18 months operation under normal conditions
30 day low battery warning signal
Interconnection function available to connect up to 38 units together
Battery missing indicator
Oct-20-16
 
The 6001 analogue addressable control and indicating equipment forms the central part of a fire detection and alarm
System. The fully networkable 2-wire 6001 is compatible with numens addressable devices and can also be connected
To non-addressable devices when used with addressable input modules.
Default configuration programming facilitates out-of-box installation and rapid commissioning. A powerful and versatile
Cause-and-effect pc-based programming tool enables rapid customization with software for sites that
Require special operating features.
The 6001 comes standard with features that allows flexibility and expandability.
Single loop or 2-loop options available
Single loop, expandable to 2-loops available
Networkable, up to 4 control panels
Up to 125 addressable devices per loop
Automatic device detection on start-up
Automatic device type-code verification
2 independently programmable non-addressable a/v alarm output circuits
2 programmable fire alarm relay outputs
Fault relay output
Backlit lcd display providing 4 rows of 40 characters
16 zone fire alarm led indicators
3000 event history log
Aug-23-16
 
The 6001 analogue addressable control and indicating equipment forms the central part of a fire detection and alarm

System. The fully networkable 2-wire 6001 is compatible with numens addressable devices and can also be

Connected to non-addressable devices when used with addressable input modules.

Default configuration programming facilitates out-of-box installation and rapid commissioning. A powerful and versatile

Cause-and-effect pc-based programming tool enables rapid customization with software for sites that require

Special operating features.

The 6001 comes standard with features that allows flexibility and expandability.

Single loop or 2-loop options available
Single loop, expandable to 2-loops available
Networkable, up to 4 control panels
Up to 125 addressable devices per loop
Automatic device detection on start-up
Automatic device type-code verification
2 independently programmable non-addressable a/v alarm output circuits
2 programmable fire alarm relay outputs
Fault relay output
Backlit lcd display providing 4 rows of 40 characters
16 zone fire alarm led indicators
3000 event history log
Aug-15-22
Supplier From Ningbo, Zhejiang, China
468 Electronic Semi Conductor Devices Other Components Suppliers
Short on time? Let Electronic Semi Conductor Devices Other Components sellers contact you.
Mar-31-23
Supplier From Ningbo, Zhejiang, China
Mar-23-07
Supplier From Ningbo, Zhejiang, China
Feb-14-11
Supplier From Ningbo, China
Dec-17-08
Supplier From Ningbo, Zhenhai, China
Mar-13-02
Supplier From Ningbo, Zhejiang, China
Jun-28-12
Supplier From Ningbo, Zhejiang, China
Jun-17-14
Supplier From Ningbo, Zhejiang, China
Mar-03-09
Supplier From Ningbo, China
Jun-09-19
Supplier From Ningbo, Zhejiang, China
Apr-09-15
Supplier From Ningbo, Zhejiang, China
Nov-03-07
Supplier From Ningbo, Zhejiang, China
Mar-25-09
Supplier From Ningbo, Zhejiang, China
May-17-11
Supplier From Ningbo, Zhejiang, China
Nov-01-07
Supplier From Ningbo, Zhejiang, China
Aug-17-13
Supplier From Ningbo, Zhejiang, China
468 Electronic Semi Conductor Devices Other Components Suppliers
Short on time? Let Electronic Semi Conductor Devices Other Components sellers contact you.
See what buyers and suppliers are discussing in Electronic Semi Conductor Devices Other Components import export community