Please click here to check who's online and chat with them.

Find Verified Electric Circuit Breakers Suppliers, Manufacturers and Wholesalers

Top Supplier Cities : Shenzhen   Guangzhou   -  
Sep-01-17
 
Advantage products
Allen bradley
1756-l62, 1756-l63, 1746, 1747, 1756, 1769, 1794, 2711p..
Schneider
140cpu43412u, 140cpu65150, 140cpu65160, 140cpu, noe, cra, cps, bmx, tcse....
Abb
Dsqc(07kt98 wt98, 07kt97 wt97, dsqc679, imasi23, imdso14...)
Bently nevada
3500/42m, 3500/22m, 3500/95.3500/15...
Hima
F3330, f3236, f6217, f7126, f8621aesd
Triconex
3805e, 3008, 3504e, 3624, 3700a, 3721, 4351b, 4119a..
Siemens moore
6es7(1.2.3.4), 6es5, 6dd, 6dp.
Ge
Ic693cpu363, ic697pwr711, ic693cpu364, , ic693, ic6 , 97, ic695, is200, is215, ds200...
Westinghouse/ , ovation
1c31194g01, 1c31197g01, 5x00106g01, 1c , 31125g02 ...
Foxboro
Fcp270, fbm203, fbm204, fbm217, , fmb231
Sep-01-17
 
Advantage products,
Allen bradley
1756-l62, 1756-l63, 1746, 1747, 1756, 1769, 1794, 2711p..
Schneider
140cpu43412u, 140cpu65150, 140cpu65160, 140cpu, noe, cra, cps, bmx, tcse....
Abb
Dsqc(07kt98 wt98, 07kt97 wt97, dsqc679, imasi23, imdso14...)
Bently nevada
3500/42m, 3500/22m, 3500/95.3500/15...
Hima
F3330, f3236, f6217, f7126, f8621aesd.
Triconex
3805e, 3008, 3504e, 3624, 3700a, 3721, 4351b, 4119a.
Siemens moore
6es7(1.2.3.4), 6es5, 6dd, 6dp.
Ge
Ic693cpu363, ic697pwr711, ic693cpu364, , ic693, ic6 , 97, ic695, is200, is215, ds200...
Westinghouse/ , ovation
1c31194g01, 1c31197g01, 5x00106g01, 1c , 31125g02 ...
Foxboro
Fcp270, fbm203, fbm204, fbm217, , fmb231
Mar-08-17
 
Miniature circuit breakers protect installations against overload and short-circuit, warranting reliability and safety for operations. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the magnetic tripping mechanism for short circuit protection.
ï?? Extra-wide and complete range of MCBs to cover most applications and markets
ï?? Meeting worldwide standards
ï?? Certificates, documentation, training or background information to support customers due to their daily work
ï?? Space and time saving thanks to frame degree updates

Main features
MCB range offer the possibility to select among different characteristics (B, C, D), configurations (1P, 1P+N, 2P, 3P, 3P+N, 4P), breaking capacities (up to 15 kA) and rated currents (up to 125A).
Compliance to the worldwide standards,
IEC/EN 60898-1
IEC/EN 60947-2
IEC/EN 60947-3
IEC/EN 61009-1
GB10963.1
GB1096.1
GB14048.2
GB14048.3
GB16917.1
Allowing the use for residential, commercial and industrial applications 25 mm2 and 10 mm2 cylinder lift twin terminals for challenging industrial use. Cross Real contact position indication, directly connected to the moving contact, for more comfort and safety
ï?? Environmental
Ambient Air Temperature: Operation -5 ... +55°C Storage -40 ... +70 °C
Resistance to Shock acc. to IEC 60068-2-27: 30g / 2 shocks / 13 ms
Resistance to Vibrations acc. to IEC 60068-2-6: 5g, 20 cycles at 5 ... 150 ... 5 Hz
Environmental Conditions: 28 cycles with 55 °C / 90-96 % and 25 °C / 95-100 %
Technical Standards: IEC/EN 60898-1
Rated Current (In): 6A, 10A,16A, 20A, 25A, 32A, 40A, 50A, 63A, 80A, 125A
Rated Operational Voltage: acc. to IEC 60898-1 230 V AC & 400V AC
Rated Insulation Voltage (Ui): acc. to IEC/EN 60664-1 440 V
Rated Frequency (f): 50 Hz 60 Hz
Rated Ultimate Short-Circuit Breaking Capacity (Icu): (230V AC & 400V AC) 15 kA
Rated Service Short-Circuit Breaking Capacity (Ics): (230V AC & 400V AC) 6 kA
Instantaneous release: Type C: Lighting protection ; Type D: Motor protection
Mar-08-17

Mseed Brand Mcb Dz47-63

$0.50
MOQ: Not Specified
 
Mcb range offer the possibility to select among different characteristics (b, c, d), configurations (1p, 1p+n, 2p, 3p, 3p+n, 4p), breaking capacities (up to 15 ka) and rated currents (up to 125a).
Aug-17-16
 
1. General
VS1 12KV vacuum circuit breaker VCB
HVD1-12(VS1-12) type indoor AC HV vacuum circuit breaker VCB (hereinafter referred to as circuit breaker) are suitable for 12kV air-insulated indoor switchgears, used as protection and control unit of power equipment of industrial& mining enterprise. Due to the super excellence, it is especially for location where requires the frequent operation of rated working current or multi breaking short circuit current.
The circuit breaker adopts the integrated design of operating mechanism and circuit breaker body, servers as not only fixed installation, but also the handcart unit through equipping with a special propelling mechanism.

2. Service conditions
3.1 Environment temperature:-15degree~+40degree;
3.2 Environment humidity: Daily average relative humidity:
610 Electric Circuit Breakers Suppliers
Short on time? Let Electric Circuit Breakers sellers contact you.
Aug-17-16
 
1. Introduction
HVD7 33KV 36kv outdoor HV AC vacuum circuit breaker VCB has many visual advantages like reasonable design, fashionable appearance, high safety and reliability, simple maintenance, long electric life. It is the ideal upgraded products of 35KV outdoor oil circuit breakers.
HVD7-40.5 vacuum circuit breaker is applicable for three-phase power system of AC 50HZ.It is used to make and break the load current ,overload current and short-circuit current.

2. Applicable environment
3.1The ambient temperature should be -30degree~ +40degree(-40degree in the frosty area);
3.2Altitude should not exceed 2000m(over 2000m is plateau type);
3.3The wind pressure should not exceed 700Pa(equal to wind speed 34m/s);
3.4Air pollution degree: 3,that of antifouling type:4;
3.5The installation site should be free from the fire, explosion, chemical corrosion and serious vibration.


1. Main technical parameters
Rated voltage: 33kv 36KV
1 minute power frequency withstand voltage, dry test: 95 kv
1 minute power frequency withstand voltage, wet test: 80 kv
Lightning impulse withstand voltage(peak value): 185 kv
Rated current: 1600A / 2000A
Rated short-circuit breaking current: 20KA, 25KA, 31.5KA
Rated short-circuit making current(peak): 50KA, 63KA, 80KA
Rated operating sequence: O-0.3s-CO-180s-CO
Rated short-time withstand current: 20KA, 25KA, 31.5KA
Rated peak withstand current: 50KA, 63KA, 80KA
Rated short-circuit duration: 4 s
Rated control voltage: AC220,110;DC220,110
Rated short-circuit breaking current break times: 20 times
Full-break time:
Aug-17-16
 
1. General
HVD32 ZW32 This vacuum circuit breaker VCB is three-phase AC 50Hz, rated voltage 12 kV outdoor high voltage switch equipment. It is mainly used to opening(closing) load current, overload current and short-circuit current. It is suitable to protect or control the city or village electrical power distribution system.
2 . Main technical parameter
Rated voltage: 12 kv
1 minute rated power frequency withstand voltage: Phase to Phase, to Ground 42 kv / Fracture 48 kv
Rated current: 630A / 1250A
Rated short circuit breaking current: 12.5KA, 16KA, 20KA / 25KA
Rated short-circuit current (peak): 31.5KA, 40KA, 50KA / 63KA
Rated peak withstand current: 31.5KA, 40KA, 50KA / 63KA
4s rated short time withstand current: 12.5KA, 16KA, 20KA / 25KA
Rated operating sequence: O-0.3s-CO-180s-CO(Electric operation)
Closing time: 30-60 ms
Opening time: 20-40 ms
Rated short circuit breaking current breaking times: 30 times
Mechanical life: 10,000 times
Secondary circuit 1 minute power frequency withstand voltage: 2000 v
Energy storage motor rated power: 40 w
Energy storage motor rated voltage V: DC220/110
Rated closing operation voltage v: DC220/110, AC220/110
Rated switching operation voltage v: DC220/110, AC220/110
Electric energy storage time: =8 s
Aug-17-16
 
1.General
HVD85 ZN85 33kv 36KV indoor vacuum circuit breaker VCB is suitable for three-phase AC power system of 50Hz and 36kV, used to make and break the load current, overload current and fault current in industrial and mining enterprises, power plants and transformer substations, meanwhile, it is suitable for the occasion where the frequent operation is required.

2. Service conditions
2.1The ambient air temperature should be -15?~40?, the daily average temperature should not exceed 35?.
2.2 Daily mean relative humidity should not exceed 95%, and the daily mean vapor pressure should not exceed 2.2kPa; the monthly mean relative humidity should not be higher than 90%, and the monthly mean vapor pressure should not exceed 1.8kPa.
2.3 Altitude: Not exceed 1,000m.
2.4 The ambient air should be free from the dust, smoke, corrosive and flammable gas, steam, salt fog, et…


Main specifications and technical parameters
Rated voltage: 33KV 36kv
Power frequency withstand voltage: 95 kv
Lighting impulse withstand voltage: 185 kv
Rated current: 1250A, 1600A, 2000A
Rated short-time withstand current: 25KA, 31.5KA
Rated peak value withstand current: 63KA, 80KA
Rated short-circuit duration: 4 s
Rated short-circuit breaking current: 25KA, 31.5KA
Rated short-circuit making current: 63KA, 80KA
Rated operation sequence: O-0.3s-CO-180s-CO
Breaking time:
Jun-21-24
 
DZ47-63 Miniature circuit breaker has novel structure,reliable performance,high breaking capacity,pleasing outlook and small size,Its case and items are adopted by high fire-resistant and shockproof plastics,It mainly used in the building office,house and similar building for illuminating at AC 50 Hz/60 Hz,rate voltage below 230/ 400 V,rated current below 63 A,distribution circuit and equipment overload,short circuit protection.It can also be used for unfrequent switch over of the circuit under normal conditions .This product conforms to the requirement of IEC 60898 and GB 10963.1 standards.
Jun-21-24
 
Specifications ID Residual Current Circuit Breaker
Rating up to 100 A
Breaking capacity up to 6 k A
Model No: ID
Rated Current: 16, 25, 40, 63, 80, 100 A
Sensitivity : 10, 30, 100, 300, 500 m A
Rated Voltage: 230 VAC(2 P), 400 VAC(4 P)
No. Of Pole: 2 P, 4 P
Type: Type AC and Type A
Breaking Capacity: 6000 A
Jun-14-24
 
"!!! Specific price, Size, Weight Are subject to Inquiry!!!"
Competitive brands:&�©|160;rexroth, HAGGLUNDS, AVENTICS, Danfoss, Parker, MOOG, sunhydraforce, EOWARDS, Leybold, INFICON ,NSK and other European and American brands.
Apr-16-24
 
The 10KA MCB features an elegant and distinctive design, offering dual protection against both short-circuits and overloads.


Feature of JVM66-63-C 10ka MCB
Notable for its fine and distinctive appearance.
Provides dual protection against both short-circuits and overloads.
Boasts an impressive high-breaking capacity of 10KA, surpassing similar products worldwide.
Features a distinct label and a transparent window for added convenience.
Offers a convenient and dependable installation method.


Specification of JVM66-63-C 10ka MCB
Model: JVM66-63-CPole No.:1P, 2P, 3P, 4P
Rated current:1,2,3,4,6, 10,13,16ï¼?20,25,32,40,50,63ARated working voltage:240/415V
Rated frequency: 50/60Hz
Rated frequency (miniature circuit breaker):400VCurve (miniature circuit breaker):B,C,D
High short-circuit breaking capacity:10000A(10KA)
lnstantaneous tripping current:5In (B type)10In (C type) 20In (D type)
Instantaneous non-tripping current:3In (B type) 5In(C type)10ln(D type)Mechanical life:10000 times
Degree of protection: IP20wiring mode:Front wiring
Connecting conductor:Up to and including 16m2Wiring height:21.5mm
Mar-06-24
 
Miniature Circuit Breaker Automatic Assembly and inspecting line
MCB Automatic Assembly and inspecting line
Keyword: Miniature Circuit Breaker Automatic Assembly, Miniature Circuit Breaker, Automatic Assembly line, Assembly Machine, Assembly Production Line

Product Introduction
Basic operation process:
ï?¼Loading by AGV robots, printing QR codes based on the product work order issued by the SAP system, and then separating the upper and lower shells.
ï?¼Bottom coating of the upper shell: The installation of three components is completed through ten processes, and after each assembly is completed, there is a corresponding installation accuracy testing process to ensure that the assembly is completely qualified.
ï?¼Installation of lower shell components, upper and lower shell assembly: A total of 25 processes are used to install 12 components. After each part is assembled, guide pins are used to ensure the upper and lower assembly. After the installation of internal components is completed, the product's on/off function is tested. After passing the test, rivets are installed, pressed again, and the screws are removed. All installations are checked, and after passing the test, they are transferred to the inspection station.
ï?¼Unipolar products undergo instantaneous detection, delay detection, cooling tower and other unit inspections, and are then labeled with QR codes and covers before being transferred to the next workstation.
ï?¼Multi pole products require 9 steps of multi pole assembly, and after assembly, a second delay is performed to verify the stability and reliability of the product
ï?¼Finally, it is transferred to the automatic packaging unit through pressure resistance testing, transfer printing, laser labeling, and buckle installation.

The specific parameters:

(1) Equipment input voltage: 220V �± 10%, 50Hz;

(2) The equipment has functions such as automatic shell loading, lid opening, assembly of arc extinguishing plates, magnetic guide plates, handle springs, base springs, positioning pins, handles, jump buckles, locks, coil components, iron core components, wiring columns, adjustment screws, arc extinguishing covers, CCD recognition, lid closing, identification of qualified and unqualified products, assembly of cutting processes, online detection, real-time monitoring, component life monitoring, data storage, MES system and ERP system networking, parameter arbitrary formula, smart energy analysis and energy-saving management system, intelligent equipment service big data cloud platform, etc.

(3) Theoretical production effeciency: 2 seconds per unit; Daily production of approximately 14400 pieces/8 hours;

(4) This device has the function of power-off to save data for 30 days, making it easy to manage production data;

(5) This device adopts touch screen operation, has a computer communication interface, and printing function
Dec-27-23
 
A&S Construction Machinery Co., Ltd. supplies all types of Circuit Breakers.

All the brands of Circuit Breakers we can provide:
CAT Circuit Breakers, KOMATSU Circuit Breakers, JOHN DEERE Circuit Breakers, SANY Circuit Breakers, XCMG Circuit Breakers, VOLVO Circuit Breakers, HITACHI Circuit Breakers, SUMITOMO Circuit Breakers, LIEBHERR Circuit Breakers, DOOSAN Circuit Breakers, CASE Circuit Breakers, BOBCAT Circuit Breakers, KUBOTA Circuit Breakers, YANMAR Circuit Breakers, HYUNDAI Circuit Breakers, DAEWOO Circuit Breakers, etc.

For other parts of the brands above, we can also provide cylinder liners, crankshafts, oil pumps, solenoid valves, solenoid coils, fuel injectors, batteries, radiators, compressors, gaskets and seals, mufflers, manifolds, turbochargers, hydraulic pumps, hydraulic motors, hydraulic valves, hydraulic couplers, bearings, reducers, bearing seats, gears, pulley, sprocket, coupling, drive shaft assembly, brakes, clutches, drive chains, actuators, alternators, cables, controllers, distributors, fuses and relays, harnesses, sensors, switches, gearcases, filters, counterweights, heater and A/C accessories, belts, etc.
Nov-14-23
 
Application
1.Electromagnetic leakage protection switch
2.Electronic leakage protection switch

Advantage
1. Better temperature stability, can work stably at -15â??-100â??
2. Nanocrystalline core has high permeability, low coercivity and low loss
3. Sensitive to weak leakage current, with good resistance to large current impact
Sep-04-19

Sf6 Circuit Breaker

$6.98K
MOQ: Not Specified
 
HVD8 /LW8-40.5 type outdoor high-pressure sulfur hexafluoride circuit breaker is three-pole ac 50 hz, outdoor high voltage switch equipment, applicable to 40.5 kV power transmission and distribution system control and protection, can also be used to contact circuit breaker and movable capacitor group.
Sep-04-19

Ac Sf6 Circuit Breaker

$20.00K
MOQ: Not Specified
 
Introduction
The LWâ?¡-252/4000-50 self-extinction Ac circuit breaker which is outdoor type finds its universal range of applications for the electrical system with elevation not greater than 2000m, ambient temperature not lower than-30C, dirtiness grade not higher than IV, alternating current 50Hz and the maximum voltage 126kV. It is used for cutting the rated current, malfunction current or switching the circuitry, to control and protect the electrical system, and it can also be used for connecting with the circuit breaker

The gas of the SF6 is employed as the arc-extinguishing medium and the dielectric material. The self-extinction technology and the new-type spring operating mechanism are introduced in the SF6 circuit breaker. Thus the circuit breaker has good qualities with long electrical life, low operation power, lower noise, high reliability, simple structure, small and long overhaul periods. It can fully replace the import same type one.

Caracteristic of structure
The breaker introduces the three-phase porcelain -pole with single interrupter structure. A spring operating mechanism is supplied and the mechanical action of the three-phase is inner connected. The gas of the SF6 is connected in the three-phase pole parts. A density controller with temperature compensation is used to monitor the gas of the SF6. Because of the self-extinction arc control principle and optimized design, it improves the efficiency of mechanism and reduces the operating power

Excellent breaking performance and long electrical life

High mechanism reliability and can be operated frequently

Because of the high insulation intensity and excellent contact movement, the breaking capacity current will not re-burn

The circuit breaker has high outer insulation level and ratio creepage distance is greater than. So it has excellent performance of resisting the filth and the earthquake, it is also can be operated safely under the environment with atrocious weather

High carrying ability: it has high capability margin as the temperature of each contact rises when it is under temperature rise test in the circuit (1.2 times 0f 4000A)

The appearance of the breaker is compact, and the installation and debugging is very easy. The maintenance is also very convenient
Sep-04-19
 
VED-12 series indoor high voltage vacuum circuit breaker is suitable for 12kV air-insulated indoor switchgear, used as protection and control unit of power equipment of industrial & mining enterprise. Due to the super excellence, it is especially suitable for locations where requires the frequent operation under rated working current or multiple breaking under short circuit breaking current. The circuit breaker adopts the integrated design of operating mechanism and circuit breaker body, servers as not only fixed installation, but also draw-out type equipped with a special propelling mechanism.
VED-12 has two main types. One is Draw-out type. Model No. is VED-12D. The other is Fixed type. Model No. is VED-12F.


Service conditions
1 Environment temperature:-15°C~+40°C;
2 Environment humidity: Daily average relative humidity:â?¤95%, monthly average relative humidity:â?¤90%; Daily average saturated vapor pressure:â?¤2.2Ã?10-3Mpa,monthly average saturated vapor pressure:â?¤1.8Ã?10-3Mpa;
3 Altitude: Not exceed 1000m;
4 Earthquake intensity: Not exceed°ree;
5 Service location: No water, flammable or explosive matter, chemical corrosive gas or drastic vibration.
Sep-04-19
 
Vacuum Circuit Breaker HVD7 40.5KV 1250A outdoor HV AC VCB from Hubei JUCRO Electric
1. Introduction

HVD7 40.5KV 1250A outdoor HV AC vacuum circuit breaker VCB has many visual advantages like reasonable design, fashionable appearance, high safety and reliability, simple maintenance, long electric life. It is the ideal upgraded products of 35KV outdoor oil circuit breakers.

HVD7-40.5 1250A vacuum circuit breaker is applicable for three-phase power system of AC 50HZ.It is used to make and break the load current ,overload current and short-circuit current.


2. Applicable environment

2.1The ambient temperature should be -30degree~ +40degree(-40degree in the frosty area);

2.2Altitude should not exceed 2000m(over 2000m is plateau type);

2.3The wind pressure should not exceed 700Pa(equal to wind speed 34m/s);

2.4Air pollution degree: 3,that of antifouling type:4;

2.5The installation site should be free from the fire, explosion, chemical corrosion and serious vibration.
Sep-04-19

Hvd32 12Kv 630A Vcb

$1.43K
MOQ: Not Specified
 
Vacuum Circuit Breaker VCB HVD32 12KV 630A VCB from Hubei JUCRO Electric
1.General

HVD32 12KV This vacuum circuit breaker VCB is three-phase AC 50Hz, rated voltage 12 kV outdoor high voltage switch equipment. It is mainly used to opening(closing) load current, overload current and short-circuit current. It is suitable to protect or control the city or village electrical power distribution system.