ALSTOM GBCDG61EG020SGCH
IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S
Technical specification
Relay model no CDG61EG020SGCH
Relay type CDG 61
Case size 3D HOR.
Application 2 O/C & 1 E/F
Current setting - O/C 0.5 to 2 amps
Contacts 3M S/R
Output contacts 2M S/R
C.T.Secondary 1 amps
Frequency 50 Hz
Burden 3 VA
Operating time 3 secs
Current setting - E/F 0.1 to 0.4 amps
High set - O/C Setting 4 to 16 amps
High set - E/F Setting 1 to 4 amps
High set/High set contact CAG 13 / 2M S/R
Name plate RFG9126 901
Outline drawing MFJ 014
Wiring diagram MADZ 821.27-1
VERIFIED
Jun-09-21
 
DEIF GENSET CONTROLLER
Automatic Genset Controller AGC-4 Mk II
The automatic genset controller AGC-4 MK II can be used as a single genset controller. Also, several AGCs can be connected in a complete power management system for synchronising projects, islanded or paralleled to the mains.

The generator controller is ideal for mission-critical applications such as hospitals and data centres, and it is capable of delivering backup power in only six seconds.
VERIFIED
Jun-09-21
 
'ALSTOM' Protection Relay
MODEL NO:- P94VP16A7C0540A;
Advanced Transformer Protection, Control and Condition Monitoring Transformers are high capital cost assets in electrical power systems. Internal faults are a risk for all transformers, with short-circuits dissipating the highest localised energy. Unless cleared quickly, the possibility of rewinding will diminish and core damage may become irreparable.The MiCOM Agile P642, P643 and P645 address all these issues - preserving service life and offering fast protection for transformer faults. A transient bias technique has been included, enhancing relay stability and CT requirements. CT saturation and no gap detection techniques have been included to improve the low set differential element operating time during CT saturation where the second harmonic blocking might be asserted. An external fault detection algorithm has been incorporated to prevent the CT saturation and no gap detection from affecting the second harmonic blocking .
VERIFIED
Jun-12-21
 
GBCCUM21PF153A
DEFINITE TIME REVERSE POWER RELAY
Technical Specifications
Model No : CCUM21PF153A
CCUM21
Case Size - 1-1/2D VERT. 10T
Current Rating Cup unit - 1 Amp CT
V.T Secondary Volts - 110 V ac
Torque Angle (MTA)I Lead V- 30 Degree
Frequency - 50 Hz
Aux. Voltage - 48 / 50 V dc
Contacts - 2 N/O S/R
Flag - Yes
Mounting - Flush
Timing Range - 2.5 - 25 Secs
Ext.Resistor - 400 Ohms 35 Watts
Name Plate VTT RZF9151-601
Name Plate RFH9072-604
Outline Diagram MFJ 013 & RFJ0349
Wiring Diagram MPDZ609-01-1
VERIFIED
Jun-12-21
 
GBCCUM21PF168A
DEFINITE TIME REVERSE POWER RELAY
Technical specification
Relay model no CCUM21PF168A
Relay type CCUM 21
Case size 1-1/2D VERT.10T
C.T.Secondary 5 amps
V.T/P.T SECONDARY 110V ac
Frequency 50 Hz
MTA Phase-Char angle 30 Deg
Aux.current or voltage 110/125V dc
Contacts (S/R OR H/R) 1 N/O 1 N/C S/R
Flag Yes
Mounting Flush
Timing range 2.5 - 25 secs
External rest 1.3K.Ohms
Name plate RFH9072-604
Name plate-1 RZF9151-601
Outline drawinG MFJ013 & FJ0349
Wiring diagram MPDZ 609-01-2
2018 Temperature Controllers Indicators Suppliers
Short on time? Let Temperature Controllers Indicators sellers contact you.
VERIFIED
Jun-12-21
 
GBCCUM21PF171A
DEFINITE TIME REVERSE POWER RELAY
Technical Specifications
Model No : CCUM21PF171A
CCUM21
AUX. CURRENT OR VOLTAGE - 110/125V DC
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 1-1/2D VERT. 10T
CONTACTS (S/R OR H/R) - 2 N/O S/R
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
MTA PHASE-CHAR ANGLE - 30 DEGREES
TIME DELAY P/U OR D/O - 0.5 - 5 SECS.
V.T/P.T SECONDARY - 110V AC
External Resistor 1.3 K.OHMS
Name Plate RFH9072-604
RZF9151-601
Outline Diagram MFJ013 & FJ0349
Wiring Diagram MPDZ609-01-1
VERIFIED
Jun-12-21
 
GBCCUM21PF174A
DEFINITE TIME REVERSE POWER RELAY
Technical Specifications
Relay Model No CCUM21PF174A
Relay Type CCUM 21
Case Size 1 1/2D V 10T
Mounting flush.
Current Rating 1 Amps
V.T.Secondary Volts. 110 V ac
Frequency 50 Hz
Torque Angle(M.T.A) I Lead 30 deg
Operating Voltage 110/125V dc
Contacts 2 N/O S/R
Flag Yes
Timing Range 6/60 sec
External Resistor 1.3 K / 35W
Nameplate RFH9072 604
RZF9151 601
Outline Drawing MFJ 013
Wiring Diagram MPDZ609 01-1
VERIFIED
Jun-12-21
 
GBCCUM21PF175A
DEFINITE TIME REVERSE POWER RELAY
Technical Specifications
Model No : CCUM21PF175A
CCUM21
Case Size - 1-1/2D VERT. 10T
Current Rating Cup unit - 1 Amp CT
V.T Secondary Volts - 110 V ac
Torque Angle (MTA)I Lead V- 30 Degree
Frequency - 50 Hz
Aux. Voltage - 110 / 125 V dc
Contacts - 2 N/O S/R
Flag - Yes
Mounting - Flush
Timing Range - 12 - 120 Secs
Ext.Resistor - 1.3K Ohms 35 Watts
Name Plate VTT RZF9151-601
Name Plate RFH9072-604
Outline Diagram MFJ 013 & RFJ0349
Wiring Diagram MPDZ609-01-1
VERIFIED
Jun-12-21

Ccum21Pf176A

$1.50K
MOQ: Not Specified
 
GBCCUM21PF176A
DEFINITE TIME REVERSE POWER RELAY
RELAY MODEL CCUM21PF176A
CCUM21
AUX. CURRENT OR VOLTAGE 110/125V DC
C.T. SECONDARY 1 AMP CT.
CASE SIZE 1-1/2D VERT. 10T
CONTACTS (S/R OR H/R) 1 N/O 1 N/C S/R
FLAG YES
FREQUENCY 50 HZ
MOUNTING FLUSH
MTA PHASE-CHAR ANGLE 30 DEGREES
TIME DELAY P/U OR D/O 0.5 - 5 SECS.
V.T/P.T SECONDARY 110V AC
EXTERNAL REST 1.3 K.OHMS
NAME PLATE-1 RFH9072-604
NAME PLATE-2 RZF9151-601
OUTLINE DRAWING MFJ013 & FJ0349
WIRING DIAGRAM MPDZ609-01-2
VERIFIED
Jun-12-21
 
CCUM21PF176A GBCCUM21PF176A
DEFINITE TIME REVERSE POWER RELAY
RELAY MODEL CCUM21PF176A
CCUM21
AUX. CURRENT OR VOLTAGE 110/125V DC
C.T. SECONDARY 1 AMP CT.
CASE SIZE 1-1/2D VERT. 10T
CONTACTS (S/R OR H/R) 1 N/O 1 N/C S/R
FLAG YES
FREQUENCY 50 HZ
MOUNTING FLUSH
MTA PHASE-CHAR ANGLE 30 DEGREES
TIME DELAY P/U OR D/O 0.5 - 5 SECS.
V.T/P.T SECONDARY 110V AC
EXTERNAL REST 1.3 K.OHMS
NAME PLATE-1 RFH9072-604
NAME PLATE-2 RZF9151-601
OUTLINE DRAWING MFJ013 & FJ0349
WIRING DIAGRAM MPDZ609-01-2
VERIFIED
Jun-12-21
 
GBCCUM21PF191A
DEFINITE TIME REVERSE POWER RELAY
Technical Specifications
Model No : CCUM21PF191A
CCUM21
APPLICATION REVERSE POWER PROTN
AUX. CURRENT OR VOLTAGE 220/230V DC
C.T. SECONDARY 1 AMP CT.
CASE SIZE 1-1/2D VERT. 10T
CONTACTS (S/R OR H/R) 2 N/O S/R
FLAG YES
FREQUENCY 50 HZ
MOUNTING FLUSH
MTA PHASE-CHAR ANGLE 30 DEGREES
TIME DELAY P/U OR D/O 0.5 - 5 SECS.
V.T/P.T SECONDARY 110V AC
NAME PLATE-1 RFH9072-604
NAME PLATE-2 RZF9151-601
EXTERNAL REST 3.3 K.OHMS
OUTLINE DRAWING MFJ013 & FJ0349
WIRING DIAGRAM MPDZ609.01-1
VERIFIED
Jun-12-21
 
GBCCUM21PF192A
DEFINITE TIME REVERSE POWER RELAY
Technical Specifications
MODEL NUMBER CCUM21PF192A
CCUM21
AUX. CURRENT OR VOLTAGE 220/230V DC
C.T. SECONDARY 1 AMP CT.
CASE SIZE 1-1/2D VERT. 10T
CONTACTS (S/R OR H/R) 2 N/O S/R
FLAG YES
FREQUENCY 50 HZ
MOUNTING FLUSH
MTA PHASE-CHAR ANGLE 30 DEGREES
TIME DELAY P/U OR D/O 1 - 10 SECS.
V.T/P.T SECONDARY 110V AC
EXTERNAL REST 3.3 K.OHMS
NAME PLATE-1 RFH9072-604
NAME PLATE-2 RZF9151-601
OUTLINE DRAWING MFJ013 & FJ0349
WIRING DIAGRAM MPDZ609-01-1
VERIFIED
Jun-12-21
 
GBCCUM21PF196A
DEFINITE TIME REVERSE POWER RELAY/VTT 11
Technical Specifications
MODEL NUMBER CCUM21PF196A
CCUM21
Case Size 1-1/2D Ver.10T
Currnt Rating Amps Cupunit 1 Amp
V.T Secondary Volts Cupunit 110 V Ac
Torque Angle (mta)I lead V 30 Degrees
Frequency 50 Hz
Aux.Voltage 220/230 V dc
Contacts 1 N/O 1 N/C S/R
Flag YES
Timing Range Secs 0.5 - 5 Secs.
Mounting Flush
External Rest 3.3 K 35 Watts
Name Plate-1 RFH9072-604
Name Plate-2 RZF9151-601
Outline Drawing MFJ013 & FJ0349
Wiring Diagram MPDZ609.01-2
VERIFIED
Jun-12-21
 
GBCCUM21PF662A
DEFINITE TIME REVERSE POWER RELAY 60 HZ
Technical Specifications
Model No : CCUM21PF662A
CCUM21
AUX. CURRENT OR VOLTAGE - 110/125V DC
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 1-1/2D VERT. 10T
CONTACTS (S/R OR H/R) - 2 N/O S/R
FLAG - YES
FREQUENCY - 60 HZ
MOUNTING - FLUSH
MTA PHASE-CHAR ANGLE - 30 DEGREES
TIME DELAY P/U OR D/O - 1 - 10 SECS.
V.T/P.T SECONDARY - 110 V AC
External Resistor 1.3 K.OHMS
Name Plate RZF9151-601 RFH9072-604
NOTE:-Relay to be caliberated at 60 Hz <(>&<)>
engrave in N'plate as 60 Hz instead of 50 Hz
Outline Diagram MFJ013 <(>&<)> FJ0349
Wiring Diagram MPDZ609-01-1
VERIFIED
Jun-12-21
 
GBCDD21PF003SACH
DIRECTIONAL IDMT RELAY SELF POWERED
MODEL No. CDD21PF003SACH
APPLICATION O/C
BURDEN 3VA
C.T. SECONDARY 5 AMP C.T.
CASE SIZE 1-1/2D VERT. 10T
CONTACTS (S/R OR H/R) 2 N/O S/R
D.M.T 3 SEC.
E/F OR U/V SETTING NOT APPLICABLE
FLAG YES
FREQUENCY 50 HZ
MOUNTING FLUSH
MTA PHASE-CHAR ANGLE 30 DEGREES O/C
O/C OR O/V SETTING 50 - 200%
V.T/P.T SECONDARY 110V A.C(O/C)
NAME PLATE-1 RFG9126-021
OUTLINE DRAWING MFJ013
WIRING DIAGRAM MPDZ801.23
VERIFIED
Jun-12-21
 
ALSTOM GBCDD21PF004SACH
SELF-POWERED DIR. INVERSE TIME O/C OR E/
Technical Specifications
Model No : CDD21PF004SACH
CDD21(SELF-POWERED)
APPLICATION - O/C
BURDEN - 3VA
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 1-1/2D VERT. 10T
CONTACTS (S/R OR H/R) - 2 N/O S/R
D.M.T - 3 SEC.
E/F OR U/V SETTING - NOT APPLICABLE
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
MTA PHASE-CHAR ANGLE - 45 DEGREES
O/C OR O/V SETTING - 50 - 200%
V.T/P.T SECONDARY - 110V A.C(O/C)
Name Plate RFG9126-021
Outline Diagram MFJ013
Wiring Diagram MPDZ801.23
VERIFIED
Jun-12-21
 
GBCDD21PF004SJCH
DIRECTIONAL IDMT RELAY SELF POWERED
RELAY MODEL CDD21PF004SJCH
CDD21
APPLICATION O/C
BURDEN 3VA
C.T. SECONDARY 5 AMP C.T.
CASE SIZE 1-1/2D VERT. 10T
CONTACTS (S/R OR H/R) 2 NO 1NC H/R
D.M.T 3 SEC.
E/F OR U/V SETTING NOT APPLICABLE
FLAG YES
FREQUENCY 50 HZ
MOUNTING FLUSH
MTA PHASE-CHAR ANGLE 45 DEGREES
O/C OR O/V SETTING 50 - 200%
V.T/P.T SECONDARY 110V A.C(O/C)
NAME PLATE-1 RFG9126021
OUTLINE DRAWING MFJ 013
WIRING DIAGRAM MPDZ801.24
VERIFIED
Jun-12-21
 
GBCDD21PF005SACH
SELF-POWERED DIR. INVERSE TIME O/C OR E/
Technical Specifications
Model No : CDD21PF005SA(M)
CDD21(SELF-POWERED)
APPLICATION - O/C
BURDEN - 3VA
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 1-1/2D VERT. 10T
CONTACTS (S/R OR H/R) - 2 N/O S/R
D.M.T - 3 SEC.
E/F OR U/V SETTING - NOT APPLICABLE
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
MTA PHASE-CHAR ANGLE - 30 DEGREES O/C
O/C OR O/V SETTING - 50 - 200%
V.T/P.T SECONDARY - 110V A.C(O/C)
External Resistor
Name Plate RFG9126-011
Outline Diagram MFJ013
Wiring Diagram MPDZ801.23
VERIFIED
Jun-12-21
 
ALSTOM GBCDD21PF005SBCH
SELF-POWERED DIR. INVERSE TIME O/C OR E/
Technical Specifications
Model No : CDD21PF005SB(M)
CDD21(SELF-POWERED)
APPLICATION - E/F
BURDEN - 3VA
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 1-1/2D VERT. 10T
CONTACTS (S/R OR H/R) - 2 N/O S/R
D.M.T - 3 SEC.
E/F OR U/V SETTING - 10 - 40% E/F
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
MTA PHASE-CHAR ANGLE - 45 DEGREES
V.T/P.T SECONDARY - 63.5 TO 190V AC(E/F)
External Resistor
Name Plate RFG9126-035
Outline Diagram MFJ013
Wiring Diagram MPDZ801.23
VERIFIED
Jun-12-21
 
Alstom Gbcdd21pf005sjch
Directional Idmt Relay Self Powered
Relay Model Cdd21pf005sjch
Cdd21
Application O/c
Burden 3va
C.t. Secondary 1 Amp Ct.
Case Size 1-1/2d Vert. 10t
Contacts (S/r or H/r) 2 No 1nc H/r
D.m.t 3 Sec.
E/f or U/v Setting Not Applicable
Flag Yes
Frequency 50 Hz
Mounting Flush
Mta Phase-char Angle 30 Degrees O/c
O/c or O/v Setting 50 - 200%
V.t/p.t Secondary 110v a.c(O/c)
Name Plate-1 Rfg9126-011
Outline Drawing Mfj013
Wiring Diagram Mpdz801.24