ALSTOM GBCDG11AF9007ACH
INVERSE TIME E/F RELAY MULTI-AUX-VOLTAGE
Technical specification
Relay model no CDG11AF9007ACH
Relay type CDG 11
Case size 1D S/E
Application E/F
Current setting 1 to 4 amps
C.T.Secondary 5 amps
Taps Std
Burden 3 VA
Operating time 3 secs
Frequency 50 Hz
Aux.voltage vdc 30-50 / 100-125 V
220-250 V dc
Contacts shunt 2 N/O S/R
Flag Yes
Mounting Type Flush
Name plate RFG9126 796
Outline drawing MFJ 012
Wiring diagram MADZ 802.26-1
Gbcdg21af106znch
Idmt Earth Fault Relay With High Set
Relay Model Number Cdg21af106znch
Cdg21
Application E/f
Burden 3va
C.t. Secondary 1 Amp Ct.
Case Size 1d V 10t
Contacts (S/r or H/r) 2 N/o 1 N/c H/r
D.m.t 3 Sec.
E/f or U/v Setting 0.1 to 0.4 a
Flag Yes
Frequency 50 Hz
High Set Type Cag17
Highset Contacts 2m S/r
Highset E/f Setting 1 to 8 a
Highset O/c Setting Not Applicable
Mounting Flush
O/c or O/v Setting Not Applicable
Name Plate-1 Rfg9126 692
Outline Drawing Mfj 012
Wiring Diagram Madz821.32
ALSTOM GBCDG21AF108ZMCH
1 POLE INV.TIME O/C OR E/F RELAY WITH IN
Technical Specifications
Relay Model No CDG21AF108ZMCH
Relay type CDG 21 Special
Case size 1D V 10T
Application O/C
Current setting 0.5 to 2 amps
Contacts 3 N/O S/R
Output contacts 2 N/O S/R
Taps Std
C.T.Secondary 1 amps
Burden 3 VA
Operating time 3 secs
High set contacts 2 N/O S/R
Flag / Mounting Yes / Flush
Highset/Frequency Cag17/50 Hz
High set cur.setting 2.5 to 20 amps
Name Plate RFG9126 771
Outline Diagram MFJ 012
Wiring Diagram MADZ 821.46-1
ALSTOM GBCDG21AF111ZNCH
1 POLE INV.TIME O/C OR E/F RELAY WITH IN
Technical specification
Relay model no CDG21AF111ZNCH
Relay type CDG 21
Case size 1D S/E
Application O/C
Current setting 2.5 to 10 amps
Frequency 50 Hz
Contacts 2M 2B H/R W/F
Output contacts 2M 1B H/R
Taps Std
C.T.Secondary 5 amps
Burden 3 VA
Operating time 1.3 secs
High set contacts/High set 2M S/R / CAG17
High set cur.setting - O/C 12.5 to 100 amps
Name plate RFG9125 774
Outline drawing MFJ 012
Wiring diagram MADZ 821.32
ALSTOM GBCDG21AF112ZMCH
1 POLE INV.TIME O/C OR E/F RELAY WITH IN
MODEL NUMBER CDG21AF112ZMCH
CDG21
APPLICATION O/C
BURDEN / D.M.T 3 VA / 1.3 SEC.
C.T. SECONDARY 1 AMP CT.
CASE SIZE 1D V 10T
CONTACTS (S/R OR H/R) 2 N/O S/R
FLAG YES
FREQUENCY 50 HZ
HIGH SET TYPE CAG17
HIGHSET CONTACTS 2M S/R
HIGHSET O/C SETTING 2.5 - 20 Amps.
MOUNTING FLUSH
O/C OR O/V SETTING 0.5 - 2 Amps.
NAME PLATE-1 RFG9125 771
OUTLINE DRAWING MFJ 012
WIRING DIAGRAM MADZ821.31