AustinMoore Prostheses:-
Austinmoore Standard Stem
Head Dia =37mm to 43mm
Stem Length=127mm
Stem Thickness=10mm
Stem Width=25mm
Degree of Device=135 degrees
Hole Dia=6.00mm
Made in ss 316 L
Austinmoore Standard Stem
Head Dia =44mm to 49mm
Stem Length=140mm
Stem Thickness=10mm
Stem Width=25mm
Degree of Device=135 degrees
Hole Dia=6.00mm
Made in ss 316 L
Austinmoore Standard Stem
Head Dia =50mm to 56mm
Stem Length=150mm
Stem Thickness=10mm
Stem Width=25mm
Degree of Device=135 degrees
Hole Dia=6.00mm
Made in ss 316 L
There is no further need to debate the virtues of monopolar versus bipolar technology for minor surgery. The Greenland RFS-4000K affords surgeons the ability to utilize both monopolar and bipolar modalities at, the frequency scientifically and clinically proven to produce the least amount of lateral heat and tissue alteration
Specification:
1. Sample rate: 1000Hz, simultaneous 12 leads recording
2. Resolution:12bit
3. Power: 5.0V (DC)
4. Patient Insulation: 4000V AC
5. Defibrillation Protection: Built-in box
6. Digital resolution: 2ª¦V
7. Frequency response: 0.05-250 Hz
8. Common mode rejection: >90dB
9. Input impedance: >10Mª+
10. Time constant: í¦3.2 s
11. Max electrode potential: í+300mV DC
12. Dynamic range: í+10mV
13. Isolate voltage: 4000V
14. Current leak: <10ª¦A
15. Patient cable: standard 10-wire, 15-pin D connection
16. PC interface: RS232
Feature:
1. Intuitive windows software interface
2.Quick and accurate analyzing system
3.Special editing system of r point
4.Optional main channel
5.Perfect analysis function of st segment
6.The analysis function of t wave of allchannels and t wave trend graph
7.Review of the ecg trend graph of every time
8.The analysis system of hrv, providing the regular sdnn, sdann, rmssd, lf, hf, time domain, and frequency domain
Qt analysis and qt trend graph
Acquire pacing ecg directly without separate channel, also have the functions of vcg, lpg, high frequency ecg, fcg.
Function (9 functions):
1. ECG: 12-lead resting PC-ECG with auto interpretation
2. VCG: Vector-cardiograph with auto interpretation
3. TVCG: Timed Vector-cardiograph
4. FCG: Frequency ECG (unique technique to detect ischemia and CAD)
5. HFECG: High Frequency ECG
6. SAECG(VLP): Signal Averaged ECG or Ventricular Late Potentials, time domain and 3-D frequency domain)
7. QTD: QT Dispersion with chroma map
8. HRV: Heart Rate Variability (time domain, 3-D frequency domain, Lorenz poincare plots
9. PMECG: Pacemaker ECG analysis
Package list:
1. Software CD
2. Dongle key
3. ECG acquisition box
4. Banana type ECG cable
5. USB data cable
6. Chest electrodes
7. Limb electrodes
8. Ground wire for earthing
9. Manual
Range of using :
Match to various types of electrosurgical unit.
Product characte
Operator will control easily for the light material and humanized outline design
Waterproof design reduces the risk of electric shock to the lowest.Drug steam sterilization.
Long cable and strong copper core ensure the electrosurgical pencil with excellent conductivity and security.
Available in push button, rocker switch and foot control configurations
Argon beam coagulator pencil.
Operative Dissector,Single User.
Introduction: Hand-controlled electrosurgical pencils with multifunctions as cutting ,coagulation,dissection,suction. With pushing-key,non-sticky extendable needle, standard Valleylab type connector and 3.2m cable.
Recommended using in deep operations: Lymphonode,dissection,cholecystectomy,hepatectomy,retictoperitoneal tumor resection,throidectomy,mastectomy,etc.
Generally applicable to general surgery, liver, gallbladder, pancreas, spleen, stomach, intestine, cancer and other complex surgery.