product features Product Characteristics
1 This Series Standard Current Transformer consists of primary winding Secondary winding composition
2 Check according to standard current ratio indicated on nameplate
3 This Series Standard Current Transformer can be used5/5or1/1The current is self-correcting
4 With casters for easy handling
Product Parameter Product Parameters
technical parameters
service conditions temperature 5+40
humidity 80%
The workplace should not have strong external electromagnetic fields unrelated to work
Allow long service at rated current
boundary dimension HL-22/23 370*170*440mm3
HL-32/33 330*190*430mm3
HL-53/62/63 (HL-62C/63C 470*230*570mm3
weight HL-22/23 13kg
PM cores are a variation on classic P cores, suitable for large high power transformers and energy storage chokes. They have larger wire slots facilitating easy assembly, but still the good shielding of a closed core shape.
PM cores can be found in transmission and radar equipment and in various high power industrial installations.
Transformer winding deformation test instrument based on the measurement of the characteristic parameters of transformer internal winding the internal fault frequency response analysis (FRA) method which is being developed in developed countries is adopted to make an accurate judgment of transformer internal fault.
After the design and manufacture of transformer is completed the line coil and internal structure are determined. Therefore for a multi-winding transformer line coil if the voltage grade is the same and the winding method is the same the corresponding parameters (Ci Li) of each line coil should be determined. Therefore the frequency domain characteristic response of each line coil is determined accordingly and the frequency spectrum of the corresponding three-phase line coil is comparable to some extent.
The distribution parameters of transformer windings will change when short-circuit between turns and phases occurs in the test process or collision occurs in the transportation process resulting in the relative displacement of the line coil and the deformation of the line coil caused by electromagnetic tension in the short-circuit and fault state during the operation process. Then it influences and changes the original frequency domain characteristics of the transformer that is amplitude change of frequency response and resonance frequency offset. The transformer winding test instrument developed according to the response analysis method is such a novel non-destructive testing equipment for transformer internal faults. It is suitable for the internal structure fault detection of 63kV ~ 500kV power transformer.
product names Electric power transformer winding deformation test instrument Transformer winding deformation detector Transformer winding deformation meterTransformer winding deformation analyzer
Product Introduction
This product is specially used for measuring the capacity of distribution power transformer measuring the no-load and short-circuit loss of transformer and has the function of harmonic analysis which is convenient for analyzing the quality of on-site power network. The device can automatically check whether the wiring is correct and display the vector diagram of the three-phase current and voltage when testing the three-phase transformer. At the same time necessary correction (such as waveform correction temperature correction unrated voltage correction calibration unrated current correction) is introduced to make the test results more accurate.
Product name Transformer capacity test instrument transformer capacity load tester
2120 Electric Transformers Suppliers
Short on time? Let Electric Transformers sellers contact you.
Dc resistancetest around group is an indispensable test project of transformer after the submission of pick up overhaul and change of subpick up switch. In general using traditional methods (bridge method and pressure drop method) measurement transformer winding group and dc resistance of large power inductance equipment is a time-consuming and time-consuming work. In order to change this situation shorten measurement time and reduce work burden of test personnel, our company developed Dc resistance rapid test instrument (hereinafter referred to as direct resistance instrument). It adopts new power supply technology featuring stable performance rapid measurement small size easy to use high measurement precision and good data repeatability. Measurement transformer is around the group and large power inductor dc resistance ideal equipment
product names Dc resistance tachometer Transformer dc resistance test instrument. Transformer winding dc resistance test instrument. Transformer direct resistance speed meter Transformer direct resistance quick test instrument Inductive load Dc resistance tachometer Inductive load dc resistance rapid test instrument Inductive load dc resistance test instrument Dc resistance tester
TKBB-S Transformer Ratio Tester is specially designed for three- phase transformer in power system especially for transformer of type Z winding and other transformers whose zero-load current is relatively high.Transformer turns ratio test is very important in order to find out the transformer has the right ratio corresponding on its rated voltage in primary and secondary. TKBB-S is single phase, automatically test set specially designed for turns ratio, phase shift and excitation current measurements of power, distribution and instrument transformer.
The on-load tap changer is the only moving part connected with the transformer circuit so more and more attention has been paid to the detection of the on-load tap changer.In the electrical equipment handover and preventive test regulations it is required to check the action sequence of on-load tap changer measure switching time etc.This device is mainly used for measuring the transition waveform transition time transient resistance of transformer on-load tap changer three-phase synchronism etc.
AC hipot tester series Testing Transformer is power plants power supply bureau and research institutions and other users to do the AC voltage test basic test equipment by the standards of the State Bureau of Quality Supervision for a variety of electrical products electrical components insulation material dielectric strength test etc. the insulation level assessment of products under the provisions of the voltage insulation defects were found in the sample and measure the ability of over-voltage.
AC HV Testing Transformer Classification:
There are four kinds of high voltage testing transformer according to the medium points:
1. Oil-immersed high voltage transformer test: large capacity cheap convenient maintenance mainstream products.
2. Inflatable high voltage test transformer : interrupter resistance and light weight.
3. Dry type high voltage testing transformer: light weight light volume can run backward price expensive.
4. Series type high voltage testing transformer: small volume low voltage light weight easy to transport and install.
product brief introduction Product Introduction
The test transformer calls the booster it is the basic test equipment used by the power station supplying and distributing the electrical power system and the scientific research unit. Which used in the insulated intension test on all kinds of electrical products electrical equipments and insulated materials testing the insulated level of products discovering the insulated objection of quizzee scaling the capacity burdened voltage
AC HV Testing Transformer Classification:
There are four kinds of high voltage testing transformer according to the medium points:
1. Oil-immersed high voltage transformer test: large capacity, cheap, convenient maintenance, mainstream products.
2. Inflatable high voltage test transformer : interrupter resistance, and light weight.
3. Dry type high voltage testing transformer: light weight, light volume, can run backward, price expensive.
4. Series type high voltage testing transformer: small volume, low voltage, light weight, easy to transport and install.
Product Introduction
TKBB-S Transformer Ratio Tester is specially designed for three- phase transformer in power system especially for transformer of type Z winding and other transformers whose zero-load current is relatively high.Transformer turns ratio test is very important in order to find out the transformer has the right ratio corresponding on its rated voltage in primary and secondary. TKBB-S is single phase, automatically test set specially designed for turns ratio, phase shift and excitation current measurements of power, distribution and instrument transformer.
The tester has wide testing range fast testing speed favorable repeatability flexible data processing convenient connection complete protection easy learning and convenient operation
The on-load tap changer is the only moving part connected with the transformer circuit so more and more attention has been paid to the detection of the on-load tap changer.In the electrical equipment handover and preventive test regulations it is required to check the action sequence of on-load tap changer measure switching time etc.This device is mainly used for measuring the transition waveform transition time transient resistance of transformer on-load tap changer three-phase synchronism etc.
product names On - load tap - changer tester transformer on - load tap - changer tester transformer on - load switch tester
Transformer, High Current Transformer, Ultra Isolation Transformer, Three Phase to Single phase transformer, Control Transformer, furnace Transformers, Special purpose transformers, Electroplating Rectifiers, Reactors, D.C.C.T. etc
Wide range of system current Ratings
Hinged terminal cover
Various mounting options like DIN rail mounting, Wall mounting
Terminal with self lifting screw with dual connection facility giving access from both sides of transformers
Product Details
It is the insulating sleeve that leads the transformer's internal high and low voltage leads to the outside of the oil tank, which not only insulates the ground as the lead, but also plays the role of fixing the lead.
Therefore, the transformer sleeve has the following requirements:
(1) it must have specified electrical strength and sufficient mechanical strength.
(2) must have good thermal stability, and can withstand the short circuit of the instant overheating.
(3) small appearance, small quality, good sealing performance, strong universality and easy maintenance folding.
Transformer bushing insulators are applied as a structure, carrying on conductor through a partition such as transformer tank and insulating it, incorporating the means of attached flange to the partition for medium voltage level.
For Entire Range of Bushings Ratings from - 1 Kv to 72 Kv & - 100 Amp. to 10,000 Amp.
All Ares Insulator transformer bushing insulators are made of ceramic materials according to IEC 672. Other Transformer bushing custom-made insulators can be supplied upon customer's request and specifications.
Toroids have the best possible shape from the magnetic point of view. The flux path is completely closed so the capabilities of the ferrite are fully exploited. Especially for high permeability ferrites
the effect of even a minor airgap in the magnetic circuit
can spoil up to 50% of the effective permeability. A further
advantage is the very low leakage fi eld which makes it a
suitable shape for power and pulse transformers.
Ring cores are mainly used for pulse- and wide band transformers and interference suppression coils but also in
special power supplies.
Due to the high saturation fl ux density
of iron powder (950...1600 mT) these
ring cores are very suitable for output
chokes carrying high DC currents.
Another application is found in lamp
dimmers as ballast choke.
The cores are made of electrolytic iron
powder, mixed with a small amount of
resin for insulation. They are coated
with polyamide 11 (thickness 0.1 - 0.3
mm). The isolation voltage between
core and winding is up to 1500 V.
RM cores were designed for use in high Q, high stability fi lter inductors.
Their shape allows economic utilization of surface area on the PCB. The range is standardized in IEC 431 and is available worldwide from many suppliers. The sizes are based on the standard PCB grid distance. RM 5, for instance, fi ts on a board space of 5 x 5 modules of 2.5 mm grid. Coil formers and clips were optimized for automated winding and mounting.
The slots provide suffi cient space for leads of windings. Magnetic shielding is not as good as with P-cores, but still
effective.