TPS ( Tide Power System,China ) Biomass gas generator set was powered by China high quality Biomass gas / Syngas / Synthetic gas engine. This series gas engine is medium speed which reduce engine wear, and is more tolerant with gas compositions because of its Naturally Aspirated Induction system ( No Turbocharger and Intercooler ). TPS Biomass gas / syngas generator set is fueled by Combustion Gasified Gas from abandoned wood chips, rice straw, weeds algae etc, Similar like CAT G3516C syngas genset. We turn Waste to Wealth, try our best to contribute to Recycling Economy and Environmental protection.
Gas Genset Output: 400kw-1100kw
Gas Engine Series: TBG6L, TBG8L, TBG9L
Alternator: Leroy Somer, Siemens
Control Panel: Comap, Deepsea, Harsen
HZ&RPM: 50HZ&60HZ, 500/600/750RPM& 514/600/720RPM
Acceptable Gas: heat value=4MJ/Nm3, Combustion Biomass Gas, Syngas, Synthetic natural gas, Gas CO, Gas H2, Coal Gasified Gas, Combustion Gasified Gas from wood chips, crops, rice straws, husk, weeds algae etc.
Switzerland Liebherr Biogas generator set : 132KW-560KW, G934, G944, G946, G9508, G9512
Applicable Gas : Natural gas generator set, Biogas generator set, LPG generator set ,Landfill gas power plant, Coal mine gas generator, coke oven gas generator, low calorie gas generator, Oil field gas genset, Shale gas generator, Syngas generator, biomass gas generator, wood gas generator, rice husk gas generator set, Pyrolysis Gas generator set, Hydrogen gas generator set, Hydrogen power gas generator, palm kernel shell syngas generator set, PKS gas generator set
Applicable Range: gas power plant, BOO power plant, BOT power plant, EPC power plant, POME power plant, CHP / Cogeneration of Heat and Power with Heat Exchanger to generate hot water or vapor, CCHP/Trigeneration of cold, heat and power, CCHP system with Broad Chiller---lithium bromide chiller (absorption-type Chiller ).
The integrated skid-mounted ozone generator system combines PLC,The integrated equipment of intelligent variable frequency pulse power supply and plate discharge body.The product optimizes the layout of equipment and pipelines, has small space requirements, high integration, and is easy to install.The skid-mounted ozone generator system is finalized and quantitatively produced in advance,With sufficient inventory and stable transportation channels, the delivery speed is fast and the lead time is short.
1) The large-scale ozone generator (1kg/h-150kg/h),
producing Typy:
*Cabinet type ozone generator,
*Container integrated ozone generator device
and supply for ozone systemic design and fix according to client requirement. We can often supply for skill service and training service and fitting for our customer.
2)large-scale ozone generator -oxygen supplier and PSA air source series.
3)Ozone generator technical parameters.
Products Introduction
The power department did some tests to solve some problems. According to theories and test results at home and abroad, the 50KV Very Low Frequency high voltage generator withstand voltage test can solve this problem. Its advantages are that not only the test results are the same, but the instrument size is small and the weight is greatly reduced.
output rated voltage power fuse Refer to the following table
Description:
Portable Medical Oxygen Molecular Sieve is high-efficiency oxygen molecular sieve of X-type molecular sieve(pore diameter:10 angstroms). It is suitable for household and medical oxygen generator with PSA. It has good selectivity of N2/O2. Easily desorption.
VLF high voltage generator 60KV.The capacity of it is 1/500 of traditional way. Greatly simplify testing procedures, That is why commonly used in the developed countries, china ministry of electric power entrust Wuhan high voltage research institute to drafting 35Kv and below XLPE insulated power cable ultra-low frequency (0.1Hz) voltage withstand test methods for promoting this approach. The instrument is developed according to China's made of this need. It can be widely used in cable, large-scale high-pressure rotary motor, power capacitors into AC voltage withstand test.
Power capacitance of single-core XLPE insulated cable (µF/km)
0.1Hz -60KV Ultra-Low Frequency High Voltage Generator
Model
Rated Voltages
Load capacity
Fuse
Weight
Useful
VLF-60
60kV
(peak )
0.1Hz, 0.5 µF
25A
Control 6
HV TANK-I30
HV TANK-II 33
25KV and below the cable Generator
0.05Hz, 1.0 µF
0.02Hz, 2.5 µF
0.01Hz, 5.0 µF
Precautions
1.Please use the STOP button and discharge by rod then shut down the power if you need to discontinue the machines which in the high pressure conditions.Otherwise it will damage the instrument!
2.Please operation it according to the screen instructions.
3.It is a normal phenomenon to see small amount of oil spill after boosting the pressure because the insulating oil in the booster is full, besides, it will not affect your use.
4.When carrying out 10KV cable test, one-phase test is strongly suggested. The voltage shall be 18KV and the frequency shall be 0.1Hz 0.05Hz 0.02Hz 0.01Hz. The manual said load capacity is the theoretical value, the scene 10KV cable length can reach 3-20km.
40KV vlf high voltage generator of this product fully complies with the standards of the electric power industry. Mechanical methods are widely used to modulate and demodulate ultra-low frequency signals, but there is no standard sine wave, some errors in high-voltage part measurement and spark discharge. The product can overcome the above shortcomings.
How to choose the suitable products for test
Please make sure that the capacitance of test products is below the instrument rated capacitance. The waveform will be influence if the capacitance of test products is too small and the instrument can not normally output when it below 0.05µF. 0.05µF capacitor in parallel to auxiliary output. Below is capacitance of some instrument for your reference.
40KV vlf high voltage generator parameter :
Model
Rated Voltages
Load capacity
Fuse
Weight
Useful
VLF-40
40kV
(peak )
0.1Hz,1.1µF
20A
Control 6
Body Boost 50
Used for cable and generator with corresponding voltage
Very Low-Frequency high voltage generator 30KV combines advanced technologies such as modern digital conversion, full computer control, automatic voltage increase, voltage reduction, measurement and protection. In the automatic upgrade process, human intervention can be taken care of. The main advantages include full electronics, small size, light weight, large-screen LCD display (clear and intuitive), printer output test report, and easy use.
Technical Parameter
1 output frequency 0.1Hz 0.05Hz 0.02Hz 0.01Hz
2 Loading capability : Table 1 for reference
0.1 Hz maximum 1.1F
0.05 Hz maximum 2.2F
0.02 Hz maximum 5.5F
0.01 Hz maximum 11.0F
3 accuracy :± (3% of full scale +0.5 KV)
4 voltage waveform distortion 5%
5 condition of use : indoor, outdoor; temperature : -10+40humidity 85%RH
6 power supply AC50 Hz 220V +5%
7 power fuse : output rated voltage Table for reference
Impulse voltage generator is mainly used for impulse voltage test of power equipment such as lightning impulse voltage full wave lightning impulse voltage truncation wave and operating impulse voltage wave to test insulation performance.Impulse voltage generator a power supply device that imitates impulse voltages such as lightning and operating overvoltages.It is mainly used in insulation shock withstand voltage and dielectric shock breakdown and discharge tests.
Scope of application: standard lightning shock lightning cut-off wave for transformers reactors mutual transformers and other high voltage electrical appliances high voltage thyristor valve SVC(HVDC) power cables all kinds of high voltage insulators bushing operation shock and all kinds of non-standard shock wave impulse voltage test required by users.Various test waveforms (standard and non-standard waveforms user-generated waveforms) can be generated by a single set of equipment.Field of application: lightning protection and lightning test for quality inspection measurement inspection and supervision organizations power equipment manufacturers railway communications aerospace and aerospace vehicles military research units universities and meteorological departments.
900kV/67.6 kJ Lightning Impulse Voltage Generator Complete Test Equipment for Transformer Reactor Cable
ZGS type DC high voltage generator used AIPWM technique adjusted the inaccuracy linearity of PWM technology let the instrument precision greatly improved. It is mainly used in the electric power department power department of industrial and mining metallurgy iron and steel enterprise for zinc oxide lightning arrester power cables transformers circuit breakers generators and other high voltage electrical equipment of DC withstand voltage test or DC leakage current test.
Product Characteristics
1ã??Dc high voltage generator adopts high frequency PWM technology to make closed adjustment with high voltage stability, small ripple factor and fast reliable protection circuit. The generator can endure direct discharge by devices of large capacitance. It is of small size and of light weight, convenient for field use.
Product Description
450kV 20kJ High Voltage Impulse Voltage Test System for Lighting Test
Impulse Voltage Test System is used for the full-wave and cut wave tests of standard lightning impulse voltages for power transformers reactors lightning rods switches bushings insulators and other test products with voltage classes of 35kV and below.
Product Characteristics
Rated parameter value
Rated nominal voltage ±450kV
Rated voltage ±150kV
Rated energy 20kJ
Total impulse capacitance 0.20F
The total series 3 series
Rated power capacity
The following waveforms can be generated when the load capacitance is 300~5000PF
2±30%/50 ±20%s Lightning impulse voltage full waveï¼?The efficiency of voltage 92%(no-load )
standard impulse voltage cut wave 2~6 The efficiency of voltage 92% (no-load)
The impulsevoltage waveform parameters all meet the requirements of IEC and GB311-97 national standards
Class voltage within 10% ~ 100% rated voltage range positive and negative synchronous range is not less than 20%.
Ignition range 10%ï½?100%
Synchronous discharge rate out of control 2%
Minimum output voltage 10un
Charging voltage instability ±1.0%
Service duration: > over 70% UN rated voltage can operate continuously every 90 seconds. Under the rated voltage of < 70% UN charging and discharging once every 45 seconds can run continuously.
We have a wide range of Fresh Water Generators of many brands & models:
Alfa Laval: JWP-16-C40 JWSP-26-C80 JWP-36-C100
JWP-26-C80 JWSP-26-C100 DPU-36-C125
JWP-26-C100 JWSP-26-C80/100 DPU-36-C100
Sondex: SFD 3 SFD 7 SFD 23 SFD 45
SFD 5 SFD 13 SFD 35 SFD 245
Sasakura: KE 15 KE 25 KE 35 KE 50
KE 20 KE 30 KE 40
APV: H20 CE H25 CE H30 CE H35 CE
Contact Goyam Marine for further information
3342 Electric Power Generators Suppliers