NH3 3E 100 Ammonia Sensor (NH3 Sensor) FEATURES
* Amperometric 3 electrode sensor cell
* Fixed organic gel electrolyte
* No CO2 interference
* 0 volt bias operation
NH3 3E 100 Ammonia Sensor (NH3 Sensor) TYPICAL APPLICATIONS
* TLV-monitoring, leakage detection
* Fixed point applications in cold storages & refrigeration plants only
* For other applications please use NH3 3E SE versions
* No background concentrations of ammonia & alcohols
NH3 3E 100 Ammonia Sensor (NH3 Sensor) TECHNICAL SPECIFICATIONS
* Measuring Range: 0-100 ppm
* Sensitivity Range: 90 nA/ppm ± 40 nA/ppm
* Zero Current at 20 deg C: < ± 150 nA
* Resolution at 20 deg C: < 2 ppm
* Bias Potential: 0 mV
* Linearity:
NH3-A1 Ammonia Sensor NH3 Sensor Description
Alphasense is expanding its line of electrochemical toxic gas sensors to address industry-specific requirements, including emissions monitoring, process safety, environmental monitoring and VOCs.
Ammonia (NH3)
Our first family of Ammonia sensors. This sensor is designed for higher concentrations of Ammonia. Sensors for lower level detection are in development.
NH3-A1 Ammonia Sensor NH3 Sensor Specifications
* Range: 200 ppm NH3 limit of performance warranty
* Sensitivity: 17 to 27 nA/ppm in 50ppm NH3
* Response time t90:
Honeywell BW Solo is a easy to service single-gas detector with BLE connectivity that provides real-time visibility into the status and safety of hazardous-area workers, helping companies respond faster, more knowingly and decisively to safety incidents. The first single-gas detector with the 1 Series sensor for CO, H2S and O2
Features & Benefits:
User-friendly operation,
Easy-to-read display for multiple languages,
Lightweight convenience,
Ease of maintenance,
Serviceability,
The new 1-Series sensor for enhanced reliability,
Connected Bluetooth Low Energy (BLE) capabilities.
4-20 mA/0-5v/0-10v Output NH3 ammonia sensor
Product Description
Our NH3 sensor uses the electrochemical principle to detect the concentration of ammonia (NH3). The reaction is rapid, sensitive, low-power, high-precision, anti-interference, and has excellent repeatability and stability. This product is widely used in the detection of ammonia in industrial, mining and environmental protection. Analog signal output, 4~20mA, 0~5V, 0~10V optional, equipment 10~30V wide voltage supply. The enclosure rating is high and can be adapted to different environmental monitoring.
Power supply
10~30V DC
output signal
4~20mA0~5V0~10V
Power consumption
0~50ppm accuracy (high precision) 0.25W
0~100ppm accuracy (high precision) 0.25W
0~500ppm 1W
Operating temperature
-20~+50
Working humidity
15%RH~90%RH
Pressure range
Standard atmospheric pressure ±10%
Stability (months)
ï¼?10%
Response time
150S
Zero drift (-20~40C)
-3~10ppm (0~100ppm products)
Repeatability
10%output value
Service life
24 months
Precision
0~50ppm accuracy (high precision) ±10%FS
0~100ppm accuracy (high precision) ±10%FS
0~500ppm ±20%FS±10ppm Oxygen content: 18%
Resolution
0~50ppm model: 0.01ppm
0~100ppm model: 1ppm
0~500ppmmodel1ppm
Detailed Images
1. High-sensitivity gas detection probe, stable signal, accurate measurement of NH3 concentration
(PPM), high accuracy.
2.Avariety of measurement ranges, 0~50PPM, 0~100PPM, 0~500PPM.
3.Avariety of analog signal output options: 4~20mA, 0~5V, 0~10V.
4. The product adopts wall-mounted waterproof shell, which is easy to install and has high
protection level. .
Installation Instructions
No output or output error
possible reason:
1) The range corresponding error causes the PLC to calculate an error.
2) The wiring method is incorrect or the wiring sequence is wrong.
3) The power supply voltage is incorrect (24V power supply for 0~10V models).
4) The distance between the transmitter and the collector is too long, causing signal disturbance.
5) The PLC collection port is damaged.
6) Equipment damage.
Notes
1) The aging test before use is not less than 48 hours;
2) Electrolyte leakage will cause injury, please do not disassemble the sensor at will;
3) The sensor should avoid contact with organic solvents, paints, chemicals, oils and high-concentration gases;
4) The sensor should not be immersed in an oxygen-free environment for a long time,
otherwise it will damage the performance of the sensor;
5) It should not be used for a long time in an environment containing corrosive gases,
corrosive gases will damage the sensor;
6) It is forbidden to store and use in high concentration alkaline gas for a long time;
7) The air inlet holes must not be blocked or contaminated.
Our Services & Strength
1.OEM servie, we can design as your requirements.
2.2 years warranty for our sensors
3.We have CE,FCC,ISO,ROHS certificates.
4.We have sensor in stock, can delivery immediately.
Ar8500 ammonia gas detector product description:
Ammonia analyzer is a continuous quantitative analysis of formaldehyde concentration apparatus, the apparatus using imported high precision electrochemical principle formaldehyde sensor, fast response speed, high precision, of its stability, good repeatability.
The apparatus is widely used in metallurgy, power plant, farms, mines, chemical, scientific research, medical, pharmaceutical, environmental protection and other fields.
Ammonia concentration detector, gas detector, gas leak detector
Characteristics of the instrument:
* adopt imported abroad electrochemical sensor
* big screen for multiple parameters of lcd backlight display, visual display unit, gas concentration, working state
* the two grade dual alarm settings, the outstanding audio sound alarm, voice of up to 80 db
* the service life of the sensor: 2 years(it can be replaced)
* power supply: 3 x 1.5v aa battery
* battery service life: about 100 hours of continuous use (when the backlight is off).
* size: 182*66*32(mm)
Ar8500 ammonia gas detector application:
* farms, animal farm ammonia detection;
* ambient air monitoring and evaluation,
* landfill ammonia detection;
* frozen field ammonia concentration;
* dangerous space into the detection;
* shop and workshop etc and the surrounding places ammonia detection;
* after decorating the house ammonia detection;
* storage tanks, pipelines, valves, leakage detection;
* waste field survey
Ar8500 ammonia gas detector technical parameters
* detection of gas: ammonia ( nh3 )
* measuring range: 0~100ppmâ??
* resolution: 0.1ppm
* basic error: 0.5ppm
* response time: less than 120 seconds
* recovery time: less than 120 seconds
* repeatability: less than â± 1%
* battery: 3 x 1.5v aa batteryâ??
Apogee photometric sensors use a photodetector with a spectral response that closely matches the sensitivity of the human eye to light; sensors include a diffuser to properly weight light incident from any angle. Apogee photometric sensors provide highly accurate illuminance measurements (lux or foot candles) at an affordable price.
Pt sensor are used to measure temp. By correlating the resistance of the rtd element with temp. .Not only does it provide good accuracy , it also provides excellent stability and repeatability.
PCFS-IR2125A level sensor contact type, it is used for tube. The principle is infrared, output signal is analog. When there is no water, the sensor outputs low voltage value; When there is water, the sensor outputs a high voltage signal. The size can be customized. The photoelectric liquid level switch has high precision, low price, high reliability and wide application environment, it is less affected by strong acid, alkali and viscosity. Photoelectric level sensors can be used for higher liquid level accuracy requirements.
China supplier Sensor D-100-02-01 for Kothagudem power
Deyang YOYIK is a strong technical force, first-class product quality, brand reputable large-scale mechanical and electrical equipment Limited. Company products covered a wide range of products sold worldwide, a number of users trust. Acting foreign first-class brand, EATON VICKERS, star, and so on products. Guarantee genuine, the spot sale.
Yoyik can offer many spare parts for power plants as below: