ZBW Type Prefabricated Substation
ZBW packaged substation, also known as prefabricated substation. It meet GB17467-1998 high and low voltage prefabricated substation and IEC1330 standards etc. As a new type of power supply and distribution device, has more advantages than traditional civil substation.
Product Description
ZBW packaged substation, also known as prefabricated substation. It meet GB17467-1998 high and low voltage prefabricated substation and IEC1330 standards etc. As a new type of power supply and distribution device, has more advantages than traditional civil substation. Such as smaller size, smaller floor area, compact structure, flexible movement, which greatly reduce period and area for construction in site, also the construction cost. Meanwhile, prefabricated substation is easy to be installed at site , can realize rapid power supply, almost maintenance free. Most particularly, it is placed at load center so that reduce power loss effectively to improve power quality, enhance the reliability of power supply and also is significant for distribution network transformation.
This substation fulfills the functions such as transformation of energy, distribution, transmission, metering, compensation, system control, protection and communication.

The ZBW prefabricated substation is composed by the high-voltage switchgear, low-voltage distribution panel, distribution transformer and enclosure. The high-voltage switchgear adopts air load switch and the transformer is dry-type or oil immersed type. The substation adopts good ventilation structure with elegant appearance and good heat-insulating performance. The temperature rise of the compartments caused by the outdoor solar radiation can be reduced to within the lowest limits on account of the upper and lower ventilation windows. The forced ventilation device and the temperature auto-controlled device should be installed in the substation. The systems of control, protection, live display and the lighting are equipped in each separate unit.
Product Features

Price and Minimum Quantity

Price: Negotiable
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Zbw Type Prefabricated Substation

Jun-18-18
 
American prefabricated substations is based on urban and rural power grid construction and development and transformation of the needs of the development of a series of products. It is the transformer body, switchgear, fuses, tap-changers, low-voltage power distribution equipment and other auxiliary equipment for the combination of transformer, to meet the user energy metering, reactive power compensation, low voltage shunt and other preparation requirements. ZGS-type modular transformer as AC 50Hz, 6 ~ 10kV network, rated capacity of 63 ~ 1600kVA independent set of power distribution equipment, both for outdoor use, can also be used indoors. Widely used in industrial parks, urban residential areas, commercial centers, high-rise buildings and temporary construction sites and other places.
Apr-18-20
 
Functional characteristics
1. The whole box body is divided into four parts: the bottom floor, the frame, the top frame and the box cover. The frame and the top frame are assembled by steel structural parts. The outer shell can be made of coloured steel plate which conforms to the heat insulation plate or steel plate. The clapboard is made of coloured steel composite plate to prevent thermal radiation and thermal guidance between different types. The exposed structural parts are treated by strict acid washing, phosphating, spraying and other processes to ensure corrosion resistance, moisture and heat resistance, mildew resistance and strong outdoor weather resistance.
2. The sub-box structure is adopted to avoid oil pollution in transformer tank.
3. Adopt new louver structure, large area of heat dissipation and ventilation, suitable for areas with strong wind. V-shaped structure design can effectively prevent rainwater from entering while enhancing ventilation.
4. Low-voltage main switch adopts circuit breakers from well-known manufacturers at home and abroad.
5. The transformer uses S11-M series fully sealed oil-immersed power transformer, which has the advantages of low loss, low noise and high efficiency. It can achieve good energy-saving effect and reduce pollution.
6. Substation has perfect protection performance, convenient operation, high and low voltage metering is optional, and can be equipped with automatic reactive power compensation device according to user's requirements.
Jun-26-17

Usa-Type Transformer Substation

$100.00K
MOQ: Not Specified
Supplier From Shanghai, Shanghai, China
 
USA-type Transformer Substation
Box-Type Transformer Substation
ZG(F)S series prefabricated substation, also called USA-type transformer substation, is an new-mode complete set of power distribution equipments that absorbs foreign advanced technology and design concept. It is also can be used in our national power girds, including these distribution systems of industrial and mining enterprises, high-rise buildings, residential areas, stations, port terminals, especially suitable for alteration of urban and rural power grids, not only reduces engineering investment and occupying area, but also shortens the installation period.
Products features
Novel design, innovative structure, smaller volume
The high voltage overload switch, plug-in fuse and backup protection fuses are placed in transformer insulating oil tank, thus substations volume becomes smaller whose occupying area is only 1/3-1/5 of normal products.
Fully enclosed, fully insulating, safe and reliable
Transformer oil tank is fully enclosed structure without conservator. The high voltage inlet wire adopts connections of elbow-type cable plug and high voltage bushing, live parts sealed within the insulator, shape a fully insulating structure. Terminal surface is zero potential which can guarantee human safety.
Advanced protection principle, economic and reliable, easy to operate
Using full range protection mode of double fuse in high voltage side and supplemented by low voltage undervoltage protection to make operation reliable and easy. The body of transformer is used with S11,S13 series, its winding adopts Dyn11,with characteristics of neutral point not drifting, good lightning performance, low loss, low noise, etc.
Jun-26-17

European-Type Transformer Substation

$100.00K
MOQ: Not Specified
Supplier From Shanghai, Shanghai, China
 
European-type Transformer Substation
Box-Type Transformer Substation
Product introduction:
XBF1,YBM series combination substation, is a complete set of equipment making the optimal combination for high voltage switch, power transformer and low voltage switch.
European-type transformer substation is with such advantages complete sets of strong, small footprint, low investment, easy installation and maintenance, attractive appearance, strong weather resistance, etc. Our company can design semi-submerged or buried whole type substation based on special conditions, so as to avoid blocking the line of sight, electromagnetic interference.
Normal operational conditions
a, environment temperature:-25C - +40
b, altitude less than 1000 meters;
c, relative humidity less than 90% (+ 25 ), to allow short-term up to 100%;
d, installation place without risk of fire, explosion, chemical corrosion and severe shock
e ,discuss with us for special operational conditions
Product structure and appearance
Jun-18-18
 
Prefabricated Outdoor Power Distribution Substation is mainly used for AC 50Hz (or 60Hz), voltage 1000V and below the circuit, under the rated load can be continuous long-term work. Usually used in machine tools, mechanical equipment as electrical control lighting and light.
The control transformer is working with the electromagnetic induction principle. The transformer has two sets of coils. Primary and secondary windings. The secondary coil is outside the primary coil. When the primary coil through the AC, the transformer core to produce alternating magnetic field, the secondary coil to produce induced electromotive force. The turns ratio of the Satons transformer coil is equal to the voltage ratio.
Dec-12-24
 
Transportation, installation and maintenance
Transportation
The factory substation should be filled with 25#(or 45#) transformer oil as indicated by the oil level gauge in the tank. During transportation and loading and unloading, it shall not be inverted or turned over, shall not impact the parts, and shall not be strongly shaken
Special attention should be paid to the lifting hook in the lifting hook of the fuel tank, and it should be lifted slowly to avoid damage to the paint on the surface of the substation by the wire rope, and even cause the center of gravity of the whole substation to shift, tilt, and fall.
Install
When the substation is installed on site, pay attention to the protection of the paint on the surface of the cabinet, do not allow the handle of the barometer, oil level meter, the thermometer, plug-in fuse and insulation sleeve element to bump, crack, etc., and the screws are not loose.
Clean the dust and dirt outside the substation, inside the cabinet door and on the surface of the insulation sleeve.
Check whether the name plate data and product certificate of the substation are consistent with the order, and check whether documents and spare parts are missing according to the packing list.
The civil diagram of the inlet and outlet of the substation cable is shown in Figure 6.
Maintenance
The factory products have been strictly adjusted assembly, do not need to be disassembled during installation, so as not to affect the performance, maintenance is limited to the following situations:
Sample analysis of transformer oil once a year;
It is found that the oil level should be supplemented in time, and the brand of oi l is the same as that in the box:
After the fuse is blown, the cause should be identified, and the specifications and models should be the same as the original specifications and models when replacing the melt core.
Jun-19-21
Supplier From Ludhiana, Punjab, India
Mar-25-19
 
S11 Series 6kV-35kV power Transformer With Off Circuit Tap Changer,power oill transformer,high voltage step up transformer,distribution transformer
The products implement the National Standard GB1094-2013 Power Transformer and GB / T6451-2015 Three-phase Oil-immersed Power Transformer Technical Parameters and Requirements, and are recommended as the major equipment products for the national urban and rural power grid construction and retrofit by the State Economic and Trade Commission.
Product Description
The products implement the National Standard GB1094-2013 Power Transformer and GB / T6451-2015 Three-phase Oil-immersed Power Transformer Technical Parameters and Requirements, and are recommended as the major equipment products for the national urban and rural power grid construction and retrofit by the State Economic and Trade Commission.
S11 series transformer adopts high quality material for copper winding, especially applying the new technology and new material for the coil insulation and active parts, thus the no-load and the load loss are obviously reduced, the performance and structure are more reliable and superior.

Product Features
 Good Economic Performance
The no-load loss for S11 series products decreased 10.3% averagely, no-load current decreased 22.4% based on S9 series.
Long Service Life
Transformer tank adopts hermetical structure, tank and tank cover can be connected by bolts or welded firmly, the transformer oil wont contact with air, so that extend the service life effectively.
High Operation Reliability
Improve the relevant sealing parts for the tank, increase the reliability and advance the technical level to ensure the reliability of the seal.
Small Installation Area
S11-M series transformer tank uses the corrugated plate radiator. When the oil temperature changes, the corrugated plate will proceed thermal expansion, which can replace the role of the oil conservator. the corrugated plate tank has beautiful appearance, less occupied area.
Mar-25-19
 
SG (B) 10 series Non-encapsulated H-class Dry-type Power Transformers,Dry type Power Transformers,hermetically sealed transformers,dry type transformer
Dry Type Transformer
Product Description
SG (B) 10 series of non-encapsulated H-class dry-type power transformers adopt the special process technology of German (MORA) dry-type transformers to ensure that the products fully meet the requirements such as fire prevention, waterproof ,environmental protection. It is the ideal product for distribution systems and widely used in the subway, shipbuilding, mining, chemical, power companies and personnel-intensive buildings as well as other special requirements of the occasion for safety.