Please click here to check who's online and chat with them.

Intelligent Vacuum Electromagnetic Starter

Supplier From China
Mar-19-19

Mining explosion-proof intrinsically safe intelligent vacuum electromagnetic starter
The explosion-proof electromagnetic starter is used in coal mines containing explosive gas (methane) and coal dust. It is suitable for the circuit of AC 50Hz, voltage 660V or 1140V, ungrounded three- phase center. Our Mining Reversible Electromagnetic Starter can carry out real-time monitoring and fault handling of the operating status through high-performance microcomputer, achieving mutual switch operation. It is 3-Loop vacuum electromagnetic starter .To local control or remote control the start and stop of three-phase asynchronous motor, and can be reversed at the stop.
Quick opening structure for this vacuum electromagnetic starter
With local control and intrinsically safe remote control function
With automatic water level control function, automatically control the start and stop of water pump according to the water level
With menu operation structure, large LCD screen display, fault inquiry, fault recording and corresponding fault alarm information, and can record the specific time when the fault occurs
With RS485 communication function, remote monitoring and control can be conveniently realized
With the multiple protection functions as short circuit, overload, leakage and open-phase

Price and Minimum Quantity

Price: $1
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Intelligent Vacuum Electromagnetic Starter

May-31-19
 
Features:

The main circuit adopts vacuum contactor, no arc, long service life and high reliability;
Adopting JDB digital protector, it has the functions of overload, short circuit, breaking phase, leakage of main circuit and blocking.
It can be equipped with liquid level controller as a special switch for water level control.

Scope of application:

This series of electromagnetic starter is suitable for the ring of explosive mixture gas such as methane and coal dust in the coal mine and its surrounding medium in the environment. Mainly used for direct start or stop AC 50Hz, rated voltage up to 1140V, rated current to 200A mining
Flameproof three-phase asynchronous motor. For local control, remote control, joint control and sequence control, the irreversible starter is available commutation is performed at the stop time; reversible starter can perform frequent positive and reverse operation on the controlled motor.

Technicial parameter:

Rated voltage, alternating, 3-phase frequency (50±1) Hz, V 127, 220, 380, 660
Rated current of maximum releases, A 16
Mar-19-19
 
Mining explosion-proof AC vacuum soft starter
The device adopts MX2 intelligent drive box, the latest technology developed by the United States BENSHAW, as the core. It can make the motor start in a controlled and smooth way, which is a good solution to the impact to the the grid and mechanical equipment when the motor starts, and extends the service life of the device. The device with the functions of perfect protection and intelligent communication, can be widely used in the coal mine industry to control the tape conveyor, fans, pumps and other motors.
With simple operation, intuitive parameter settings, Our Mining AC Vacuum Soft Starter is mainly used in underground coal mines, where there are mixed explosive gases, such as methane. This Reversible Soft Starter is used to control and protect the motors frequently started in the power system, which is 3-phase neutral point ungrounded, with rated voltage 6kV, rated frequency 50hz and rated current up to 300A. If you are interested in our High Voltage Vacuum Soft Starter, please call us at any time.
Jul-11-12
 
Model : WGQH high voltage cage motor soft start / soft stop
Description: National patent owned ,digital intelligent control
1) Main function
High voltage motor will creat big shake if start or stop directly, heavily influence the motor service life and loaded equipment , some times motor burnt .

WGQH motor soft start/ stop is high-tech national patented product .
1) reduce motor start current, high efficient in saving power
2)much motor protection function (as following introduction)
3)easy install, free maintenance, save maintenance cost
4)highly increase the motor service life
5)accurate setup start torque /start current/start time/ stop time/ etc
6) can connect to computer, PLC

2)USING AREA:
suitable motor AC squirrel cage motor
Rated voltage <=10KV
Rated current 75A ~ 600A
Rated power 500KW ~11000KW
cabinet size mm 2300X1300X1560
working condition ( if special, pls clarify) temperature -20C ~ + 50C
air humidity <=90%
Altitdue normal 2000m
power frequency 50Hz +/-2Hz

3)Working principle:
1> IT adopts DSP controlling technique,power and electron technique, and multiple SCR series/parallel to motor, to protect the motor completely.
2> it has a high effect of over 96%(top to 97%)
3>:the device combines series¶llel thyristor, professional insulating material imported with original packing and modern power& electric control technology
4)Unique Feature:
1> It perfectly protect the stator and motor from faults like short circuit, over current,current limiting, over-voltage, under-voltage,over load, open-phase, 3 phase unbalance, over heat, communication fault,

2>the main circuit is equippment with component-based structure,modularized installation method, can reach the target of multiiple onver-voltage absorption and protection.

3>it multiply limiting the clamp of transient dv/dt, lighting impulse voltage,operation wave over-voltage and that of transient transition process. it has unique measure and methos to reach pressure balancing of di/dt, valve recanalizing and turn-off.

4>different current intensities are isolated perfectly, the system adopts high anti-interferential digital contactor, matched with fiber/CT isolation transforming technology, which help to avoid interference of each current, making the high voltage performance is as reliable and safe .

5>:the specially designed fault detection return and judging system can pass the detecting result to the control circuit in time and start the sound and light alarm

6>unique heat dissiipation design can effectively cool the thyristor and machine

7>it is of small volume, low power dissipation, high sensitivity, and non-contact and so on, also easy to install.


wooden case.
Aug-29-14
 
Wgqh series of high voltage solid soft starter

Performance characteristics
The device combines series & parallel thyristor, professional insulating material imported with original packing and modern power & electric control technology, which is applicable to large and medium high voltage soft starting equipments with motor.
Mar-07-14
 
Jjr3000 series intelligent soft starter adopts international advanced electronics technology, mcp technology and modern control theory to efficiently limit start voltage of asynchronous motor. The equipment could be widely applied to fan, pump, conveyor, and compressor and other heavy load equipment. It is an excellent product to substitute traditional startup equipments such as star/triangle transition, self -coupling voltage reduction, magnetron voltage reduction and so on.
May-23-14
 
Mfld electromagnetic flowmeter is operating based on principle of the electromagnetic induction law of faraday, and the sensor consists of measuring tube, electrode, induction winding, iron core and yoke. It is mainly used to measure the volume flow of the conductive liquid and slurry in a close tube, such as the acid, alkali, salt and other fluid which is easurement will not be affected by the density, viscosity, temperature, pressure and conductivity of the liquid. The lining and electrode materials are manufactured with good corrosion resistance and abrasion resistance. Adopt a novel way e and conductivity of the liquid.
E program is reliable;
7. The measuring system is bidirectional and three integrators inside: positive total, reverse total and difference value total. The positive total and reverse total are both displayable. It also has multiple ways of output: electric current, pulse; digital communication, hart.
8. The mounting technology of converter is surface mount technology (smt) which possesses self-check and self-diagnose functions.


Export standard packing according to buyer's requirements
Sep-01-11
 
The soft starter of air-conditioning TL-ASSU220P3 is an embedded air-conditioning controller.It regulates the start-up voltage and current of the compressor intelligently by utilizing advanced micro-control technology of SCM,and effectively reduces the instantaneous current and power of the compressor while starting-up,thus protects the compressor and prolongs its life.Simultaneously,it also depresses the shock while air-conditioning starting up in the power supply network.

The most important feature of our product is it can control the highest launching transient current of air conditioner to be about 2 times as great as its rated current.never exceed 3 times.It can effectively protect air conditioner compressor, extend its service time. Additionally, when it detects the compressor couldn't start because of the imbalance of pressure,it will protect the compressor, then restart after 90 seconds.So then effectively prevents the compressor from overburning for failure start.

Main technical parameters
Highest continuous working voltage: 250VAC.
Highest continuous working current: 18A.
Highest non-repetitive inrush current: 400A(<20 ms).
Highest launching transient current: 180A(<350 ms).
Effective stimulating number: >100,000 times.
Startup time: 0.5-1.5s
Non-flammable capacity: The insulating material must be no flame, not too hot and its burned depth is less than 7 mm when its temperature reaches 850 C or 650 C with or without the contact of the high power.
The insulating resistance of the chassis and the shell: >300 M ohms.
The tolerant pressure between the chassis and the shell: >3000 V/AC in 1 minute.
Ambient temperature: -40 to 85 C.
Relative Humidity: 0~95% RH(<40 C).
Anti-impact: 200m/s2 and 11ms.
Anti-shock: 10-55mm(double amplitude,1.5mm)
Non-rusty capacity: Components with metal layers can withstand at least a 24-hour salt spray test.

Application: Single-phase 1P/2P/3P air-conditioner.


Dimension: 120mm*70mm*20mm
Weight:200g.
Jul-11-12
 
Model: Efficient 75kw to 10000kw AC wound rotor motor soft starter
1) direct starting problem
motor will create big current shake if start directly ( 5-8 times more than rated current), it makes big strike for electic grid and loaded equipment, heavily reduce motor and equipment service life,Sometimes motor burnt .so,stepless smooth start and stop is neccessory

2) intelligent WYQ6 main function
1:smooth start, without shook to equipment, extend the using life,save equipment maintain cost
2:reduce start current, reduce temperature increasing of motor, largely extend the long of motor,
3:Full protect motor and loaded equipment

3)range of application:
suitable to heavy load soft starting of wound rotor asynchronous motor,
especially in industrial or mines with unstable or lower voltage

4)unique feature:
1: low starting current: the starting current is<= 1.3Ie(A)
2: simple structure, easy for install and maintenance
3:it can start under a lower voltage, for example, start in 5.5KV when rated voltage 6KV
4: Good uniformity, applicable to coiling motor soft s tarting under any load situation, specially for heavy load starting
5: Multiple protection function like starting overtime, over stroke, over temperature,etc
6: can started continuously for 5-10 times
7: adpts worm gear and worm lifter as the transformation tool, which is stable,reliable and noiseless

5)operating principle:
For wound rotor asynchronous motor, when the grid voltage and frequency are invariant,
the connection of the starting resistor to the rotor loop will reduce the starting current and get a larger starting torque.

putting special compound electrolyte into the rotor loop of the controlled winding motor as the liquid resistance, when the stator receive the signal of the motor starting, it will change the location of the electrolyte automatically, so as to reduce the resistance value gradually. when the resistance reached the minimum level, the sensor closed and motor rotor star connected directly, then the equipment start smoothly with a low current, large torque.
suitable motor AC wound rotor motor
Rated voltage 380V~ 10KV
Rated power 75KW ~11000KW
Start current less than motor rated current 1.5 times at least
continous start time 5~10 times
cabinet size mm To demand
working condition ( if special, pls clarify) temperature -40C ~ + 50C
air humidity <=90%
Altitdue normal 2000m


wooden case.
Apr-02-19
Supplier From Shenzhen, Guangdong, China
 
1. Reduce the starting current, reduce power supply peak current, reduce the cost of distribution equipment. Reduce the abrasionmotor, improve the service life of mechanical equipment.

2. Optional starting parameters are convenient in one soft starter starting different motors.

3. Soft starter inspects motor feedback voltage to realize closed loop control, ensure the motor start-up success in different conditions and different loads.

4. A variety of starting ways: voltage ramp starting way can get the maximum output torque; Current limiting can realize biggest limitations of the soft start starting current.

5. Reliable quality assurance: using computer simulation design; SMT production process; Excellent electromagnetic compatibility performance, High temperature aging, vibration test of the machine before delivery.

Verification Status