Please click here to check who's online and chat with them.

170M6810D Square Body Fuse

Supplier From China
Jul-11-18

Quick Details
D/C:
Specialty Fuses 1100A 1kV 3BKN-80 AR 170M6549 Square Body Fuse
Package:
carton box
Model Number:
170M6549
Type:
fuse
Brand Name:
170M6549
Place of Origin:
Denmark
item:
Bussmann Fuse
Current:
1100A
Voltage:
690V
Datecode:
New
MOQ:
1 PC
Condition:
original & New
Warranty:
60 days
Shipping:
DHL, FEDEX, TNT, UPS, EMS, SF, etc.
Package Type:
Carton Box
Operating Temperature:
Standard

Price and Minimum Quantity

Price: $370
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: 170M6810D Square Body Fuse

May-23-19

Square Body Fuses Bases

$2.50
MOQ: Not Specified
 
1:Rated voltage: AC 690v/1000v/1250v

 2:Rated current:160-1250A 

 3:Applied size:000/00/1/2/3/4 

 4:Way of mounting:Boil/Rail

  5:Applied seires:NH series,square body blade type high speed series;

  6:Standard: IEC 60269-1-2,VDE0636-1-2,DIN43620

Delivery Port: Shanghai / Ningbo

HS code: 85361000

Brand name: CFriend
Jul-11-18
 
Quick Details
D/C:
Specialty Fuses 1100A 1kV 3BKN-80 AR 170M6549 Square Body Fuse
Package:
carton box
Model Number:
170M6549
Type:
fuse
Brand Name:
170M6549
Place of Origin:
Denmark
item:
Bussmann Fuse
Current:
1100A
Voltage:
690V
Datecode:
New
MOQ:
1 PC
Condition:
original & New
Warranty:
60 days
Shipping:
DHL, FEDEX, TNT, UPS, EMS, SF, etc.
Package Type:
Carton Box
Operating Temperature:
Standard
SupplyAbility
SupplyAbility:
1200 Piece/Pieces per Week Square Body Fuse
Packaging & Delivery
Packaging Details
carton box
Delivery Time
within 3 days after payment
Port:
Shanghai
Lead Time :
within 3 days after payment
Jun-18-19
Supplier From Shenzhen, China
 
Indicators
High speed square body fuses are available with the following
indicators.

Visual indicator
The indicator situated in one end plate is clearly visible as soon as
the fuse has operated. The minimum rated voltage for operating the
indicator is 20 V.

Type T indicator
The indicator is situated on one cover plate with a cover plate tag
to accommodate an auxiliary switch. The minimum rated voltage for
operating the indicator is 20 V. A special low rated voltage indicator
(1.5 V) is available on request.

Type K indicator
The indicator is situated on the fuse body. It is covered by an adapter
for snap-on mounting of a microswitch. The rated operating voltage
of the indicator is 1.5 V. As a matter of safety, the factory mounted
adapter must not be removed from the fuse.

Microswitches
High speed square body fuses with either Type T or K indicators
can be equipped with a microswitch for remote signaling of fuse
operation. All microswitches have one normally open (NO) and one
normally closed (NC) contact.

Ratings
Volts 250 Vac
Amps 5 A

170H0235
170H0236
170H0237
170H0238
170H0069
May-08-14
Supplier From Shenzhen, China
 
Bussmann is the world leading manufaturer for circuit protection.

170 series product is used widely in high power inverter, rectifier, convertors which need to protect the semiconductor.

The product part no:
20
170m8 series, e.G:170m8056
170t7020
170e2091
170e2093
170e2095
170e2097
170e2098
170e2161
170e3579
170e3581
170e3586
170e3949
170e4276
170e5417
170e5420
170e5421
170e6143
170f3002
170f3003
170f3004
170f3005
170h3003
170h3004
170h3005
170h3006
170l7278
170l7290
170l7299-h
170l9572
170l9576
170l9578
170l9581
170l9583
170l9665
170l9868
170t8073


1~10pcs/box;
Standard lot size: size000~size4
Weight: depends on products
Dimensions: depends on products
Jun-14-19

Bussmann Iec Standard Fuse 63D33

$100
MOQ: Not Specified
Supplier From Shenzhen, China
 
D16, D27, D33, D125 DIN Type D Diazed fuses
DIN style Type D ceramic body low voltage fuses.

Ratings
Volts 500 Vac
Amps 2-100 A
IR 50 kA

Agency information
IEC 60269 and DIN 49515, CE

2D16
4D16
6D16
10D16
16D16
20D16
25D16
2D27
4D27
6D27
10D27
16D27
20D27
25D27
35D33
50D33
63D33
80D125
100D125
Aug-20-21
 
In electrical distribution, a fuse cutout or cut-out fuse is a combination of a fuse and a switch, used in primary overhead feeder lines and taps to protect distribution transformers from current surges and overloads. An overcurrent caused by a fault in the transformer or customer circuit will cause the fuse to melt, disconnecting the transformer from the line. It can also be opened manually by utility linemen standing on the ground and using a long insulating stick called a "hot stick".
Wholesale Fuse Cutout â??s Construction
The fuse elements used in most distribution cutouts are tin or silver alloy wires that melt when subjected to high enough current. Ampere ratings of fuse elements vary from 1 ampere to 200 amperes.
Standards
Up until the mid-1990s each manufacturer used their own dimensional standards for cutout design; by the late 1990s most cutouts were of an "interchangeable design". This design allows for the interchangeable use of cutout bodies and fuse holders manufactured by different vendors.
Sep-26-17
 
Fuse Manufacturing
Ya Xun focus on the new over-current | overheating electronic protection components of the research, development, manufacturing and sales, access to a number of world-class fuse patent, with over-current protection alloy wire and overheating protection of fusible alloy wire and other advanced technology, using German automated production process. Provide a full range of current fuses, thermal fuses and other products, high performance, reliability, electronic circuit protection is the best choice.
Ya Xun for domestic and foreign customers with professional free design and application services, and to quickly deliver, excellent cost-effective to win customers praise. Ya Xun has a complete engineering research and development center,
Is the world with a small number of industry at the same time have the materials, equipment, technology patents, as well as computer simulation technology, mechanical and electrical integration R & D strength of the company, manufacturing efficiency, protection of electronic components in the field of world leader.
Our engineers combine the advanced technology of fuses and thermal fuses with traditional industrial technology, to provide you with one-stop from the rapid proofing to small batch production services. Please contact our professional team, let us come for you to achieve all the technical requirements.

What Is A Fuse?
Fuses are also known as current fuses, and the IEC127 standard defines it as a "fuse body." It is primarily a function of current overload protection. When the circuit fails or abnormal, accompanied by rising current, and the rising current may damage some important devices in the circuit, it is possible to burn the circuit or even cause a fire.
If the circuit correctly install the fuse, then the fuse will rise in the current to a certain height and heat, when the fuse itself cut off the current, so as to protect the safe operation of the circuit.

Fuse Characteristics
Resistivity is large; low melting point.
Small size, easy to install
Disjunction capability precision, reliability
Different structural features, installation in various forms
Under normal conditions, the fuse has a long shelf life
Recoverable fuse, reset can be repeated use
Long life of the fuse, in case of fault-free circuit, synchronized with the life of the equipment
Sep-26-17
 
Structural Classification Of Thermal Fuse
organic type metal shell temperature fuse is a combination, the composition of the structure are:
1. Pin (A), 2. Sealed resin, 3. Insulating ceramic, 4. Fine spring, 5. Star reed, 6. Coarse spring, 7. wafer, 8. temperature sensing block, 9. The housing, 10 Pin (B).

When the temperature insurance is in normal operation, the current flows from the left lead to the sliding contact and flows through the metal housing to the right lead. When the external temperature reaches the predetermined temperature, organic matter can melt melt, the compression spring will become loose. That is, spring expansion, sliding contact (slidingcontact) and the left side of the separation. The circuit will cut off, the current between the sliding contact and the left lead is cut off. the temperature fuse will fail and can not be used again.

2, easy to melt alloy wire thermal fuse has ceramic shell and square shell, its temperature sensing element is a fusible gold.
Product structure: is the axis of the symmetrical lead, fusible alloy wire, and resin mixture and insulated porcelain tube, plastic shell.

When the temperature rise of the heating element is set to a temperature, the resin mixture begins to liquefy, when the melting point is reached, with the help of the resin mixture (increasing the surface tension of the melted alloy), has been molten alloy wire in the resin mixture under the action of tension, quickly to both ends of the wire as the center shrink into a spherical, and thus permanently cut off the circuit.

Technical Parameters And terminology Of Thermal Fuses
(1) Rated operating temperature (Tf):
The temperature fuse is tested according to the standard method to change the temperature of its conductive state. According to IEC6091 standards-based security provisions, the temperature fuse must be operated within the rated operating temperature + 0 / -10 C (the Japan Electrical Supplies Act provides a tolerance range of ± 7 C).
(2) Operating temperature Found:
The temperature fuse is heated in the silicone oil tank at a rate of 0.5-1 C per minute, detection current is less than the fusing temperature measured at 10mA condition. It is the actual operating temperature of the temperature fuse.
(3) Holding temperature (Th):
When the temperature fuse passes the rated current, can hold for 168 hours without changing the maximum temperature of its conductive state.
(4) limit temperature (Tm):
Temperature fuse can withstand the maximum temperature for 10 minutes reconnection phenomenon never occurs.
(5) Rated current (Ir):
The maximum current that the temperature fuse can carry.
(6) Rated voltage (Ur):
Temperature fuse maximum operating voltage.
May-04-16
 
Application:Glass fuses, are widely used in power supplies, switching power supply, adapter, charger, LED driver power supply, all kinds of household appliances
The Product Sells Point:
Key Specifications/Special Features:
Functional Characteristics
Testing current

Blow Time
Min

Max
150%

1hour

/
210%

100ms

1800s
275%

50ms

2s
400%

10ms

300ms
1000%

/

20ms
5 * 20 fast Blow glass fuse

Breaking Capacity
35A or 10In whichever is greater
Material
Fuse body –glass tube
End cap--nickel plated brass
Pigtail--tin plated copper on nickel plated brass cap

Verification Status