Please click here to check who's online and chat with them.

Imr Ex660 Smart Sensor Gas Detector

Supplier From China
Apr-19-18

IMR EX660 SMART Sensor Gas Detector MAIN FUNCTION AND FEATURES
* SMART sensor module, easy for replacement and maintenance
* Intrinsically safe design
* Wide screen LCD
* High / Low alarm adjustable
* Calibrating level adjustable for each calibration
* Combustible gas channel with high-concentration protection function
* Low-voltage alert
* Internal memory storage of measurements (100,000 records)
* Data upload to PC
* Audible, visual and vibration alarm method
* Self-test power on
* Self-diagnostic and self-correction function

IMR EX660 SMART Sensor Gas Detector TECH SPECIFICATIONS
* Target gas: combustible gas, toxic gas, Oxygen, VOC
* Detecting method: Natural diffusion
* Response Time:
Semi-conductor, Catalytic, Thermal Conductivity t 90 < 30s
Oxygen, Carbon Monoxide, Hydrogen Sulfide t 90 < 30s
Other Sensors t 90 < 120s
* Working Conditions:
Combustible Gas: -40'C ~ 70'C
Toxic Gas: -20'C ~ 50'C
Working humidity â?¤ 95%RH non-condensating
* Power Source: Lithium battery (DC3.7V 6600mAh)
* Charging time: 4 ~ 6hours
* Continuous working time:
30 hours (for combustible gas and toxic gas)
300 hours (for toxic gas under temperature of 20'C)
* USB connectivity for data transfer
* Explosion-proof grade: Exia II CT4
* Ingress protection: IP65
* Dimensions: 168mm x 91mm x 45mm
* Weight: about 500g

Price and Minimum Quantity

Price: $1
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Imr Ex660 Smart Sensor Gas Detector

GOLD Member
Dec-26-22
Supplier From Dhaka, Dhaka, Bangladesh
GOLD Member
Mar-28-23
 
RP-2001 is a UL listed six-zone fire alarm control panel for single and dual hazard deluge and preaction applications, providing fire detection, signaling and protection for commercial, industrial and institutional buildings requiring water-based releasing.!
Features & Benefits:
1. Designed for sprinkler standards NFPA 13, 15 and 16.
2. Dual hazard operation.
3. Cross-zone (double-interlock) capability.
4. Six programmable Style B (Class B) IDCs (Initiating Device Circuit).
5. Optional Digital Alarm Communicators
GOLD Member
Mar-28-23
 
RP-2002 is a UL listed six-zone fire alarm control panel for single and dual hazard agent releasing applications, providing fire detection, signaling and protection for commercial, industrial and institutional buildings requiring agent-based releasing.

Features & Benefits:

Disable/Enable control per input zone and output zone.
Extensive transient protection.
Dual hazard operation
Meets International Building Code (IBC) seismic requirements
GOLD Member
Feb-01-23
 
The Notifier NBG-12 Series Pull Station is a fire alarm initiation device that allows manual activation of the fire alarm system. It typically consists of a red or yellow manual-pull handle or lever, which when activated, sends a signal to the fire alarm control panel to initiate an alarm. The NBG-12 series is designed for use in fire alarm systems and is commonly used in commercial, industrial, and residential buildings. The product is known for its durability and reliability, and it meets industry standards for fire alarm systems.
GOLD Member
Oct-10-24
 
The FK-5-1-12 Clean Agents, also known as NOVEC1230 Fire Suppression Agents, is a highly efficient and reliable hydro-fluorocarbon fire extinguishing solution. This product is designed to quickly and effectively suppress fires in various settings while being non-toxic, environmentally friendly, and safe to use.

Model Number: FK-5-1-12 clean agents


Product Name: NOVEC1230 Fire Suppression Agents

Reliability: High

Model NO.: FK-5-1-12 clean agents

Application

The FK-5-1-12 Clean Agents is suitable for use in various applications, including but not limited to:

Commercial buildings
Industrial facilities
Data centers
Telecommunication rooms
Museums and art galleries
Power generation plants
Server rooms
Control rooms
Storage facilities
Jan-18-23
 
Single Gas Detector
A single-gas detector is a device that detects the presence of any gas within an area, usually as part of a safety system. This type of Single-Gas Detector Equipment is used to detect a gas leak and interface with a control system so a process can be automatically shut down. A gas detector can also alert operators in the vicinity of the leak, allowing them to leave the area.

We supply an immense choice of gas finders and screens for various applications like oxygen, combustible gases, and carbon monoxide. The gas detector adopts an embedded MCU controller detector adopts and is easy to operate,

These units can be provided with sensors to recognize the most well-known gases as well as a scope of more extraordinary gases for changing applications. VS-70 xx portable gas detector locators are additionally accessible with a PID sensor to identify the presence of volatile natural compounds and with infrared IR sensors for the estimation of CO2 and other combustible gases.

FEATURES :
Single gas detector individually we can provide gas detectors for the following gases:

Oxygen

Combustible Gases

LPG

Hexane

Hydrogen

Carbon Monoxide

Hydrogen Sulphide

Chlorine

Sulfur Dioxide

Ammonia

Hydrogen Chloride

Hydrogen

Nitric Oxide

Nitrogen Dioxide

Ethylene

Phosphine

Phosgene

Ozone And Many More
VERIFIED
Jul-18-22
 
Metal Detector
May-17-13
 
Our detector is equipped with power and 2-step led indicators, which provide clear information about power and alarm. The state-of-the-art sensing element is ul approved, which ensures the reliability of the detector. The various models provide different solutions to protect household from any possible damage which might be caused from gas applications. You can also have ags-4xx series detecting both co and lng for a complete protection.
This product series is CE approved.


120*41(mm), 310g
Sep-08-10
 
Basic features

Mcu processing
High stability sensor
Ceiling mounted
Independent & network option
Direct current 12v
Auto reset after alarm

Technical parameter

Detecting gas:town gas.Co
Working voltage:12v dc
Standby current:ín120ma
Alarm current:ín60ma
Alarm density:50í½300ppm
Buzzer:í²70db(1m)
Operating condition:-10íµí½+55íµ; relative humidityín90%rh
Stability:regular alarm density erroría80ppm
Repeatability:repeative alarm density erroría80ppm
Alarm density error:ía80ppm
Alarm mode:sound&flash alarm/network alarm signal
Size:ª¦115íß51mm


Packing:80pcs/ctn gw:16.6kgs d:515*335*520

Verification Status