Please click here to check who's online and chat with them.

Anesthesia Machines

Supplier From United States
Sep-26-17

Product Description:

Datex Ohmeda S/5 Aespire

Clinician-inspired solutions help improve patient care

Features
- Enhanced monitor integration capabilities with our Datex-Ohmeda Anaesthesia Monitor and Compact Anaesthesia monitor
- Lightweight and compact for easy manoeuvrability
- Optional integrated auxiliary O2 flowmeter and suction control

General Specifications:
Dimensions
- Height: 134.5 cm/52.9 in
- Width: 72 cm/28.3 in
- Depth: 73 cm/28.7 in
- Weight: Approximately 108 kg/238 lb.

Top shelf
- Weight limit: 34 kg/75 lb.
- Width: 66 cm/26 in
- Depth: 40 cm/15.75 in

Work surface
- Height: 81.7 cm/32.2 in
- Size: 2160 cm-2/334 in-2

DIN rail
- Side of machine: 34.5 cm/13.6 in

Drawers (internal dimensions)
- Height: 17.5 cm/6.9 in
- Width: 33 cm/13 in
- Depth: 26.5 cm/10.4 in

Absorber bag arm (optional)
- Arm length: 30.5 cm/12 in
- Bag arm height (adjustable): 87 cm (34.3 i) to 104 cm (40.9 in)

Casters
- Diameter: 12.5 cm/5 in
- Brakes: Individual locking front casters

Electrical Specifications
Current leakage
- 100/120 V: < 300¼A
- Power
- Power input: 100-120 Vac, 50/60 Hz
- Power cord: Length: 5 m/16.4 ft.
- Rating: 15A @ 120 Vac

Inlet/outlet modules (120 V)
- System circuit breakers: 15A
- Outlets (optional): 4 outlets on back, 3-2A, 1-3A individual breakers, optional isolation transformer

Pneumatic Specifications
Auxiliary common gas outlet
- Connector: ISO 22 mm OD and 15 mm ID

Gas supply
- Pipeline input range: 240 kPa to 600 kPa/35 psig to 88 psig
- Pipeline connections: DISS-male, DISS-female, DIN 13252, AS4059, S90-116 or NIST (ISO 5359). All fittings available for O2, N2O, and Air, and contain pipeline filter and check valve.
- Cylinder input: Pin indexed in accordance with CGA-V-1 or DIN (nut and gland); contains input filter and check valve
Note: Maximum 3 cylinders; two inboard mounted, one outboard mounted.
- Primary regulator diaphragm minimum burst pressure: 2758 kPa/400 psig
- Primary regulator nominal output: < 338 kPa/49 psig Pin indexed cylinder connections
- < 407 kPa/59 psig DIN cylinder connections

Environmental Specifications
System operation
- Temperature: 10° to 40°C/50° to 104°F
- Humidity: 15 to 95% relative humidity (non-condensing) per IEC 68-2-3
- Altitude: -440 to 3565 m/500 to 800 mmHg

System storage
- Temperature: -15° to 50°C/-5° to 122°F
- Humidity: 10 to 95% relative humidity (including condensing) per IEC 68-2-3
- Altitude: -440 to 5860 m/375 to 800 mmHg
- Oxygen cell storage:
-15° to 50°C/5° to 122°F
10 to 95% relative humidity
500 to 800 mmHg

Electromagnetic compatibility
- Immunity: Complies with all requirements of EN 60601-1-2
- Emissions: CISPR 11 group 1 class B
- Approvals:
UL 2601-1
CSA C22.2 #601.1
EN/IEC 60601-1
CE 0197


Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Anesthesia Machines

Nov-13-09
 
Technical data:
Concentration range:
Halothane : 0 to 5%
Enflurane : 0 to 5%
Isoflurane: 0 to 5%
Sevoflurane: 0 to 8%

Temperature range:
Ambient and vapor temperature
During operation 15 to 35oc
During storage (empty, dry wick) -40 to 65oc

Flow range
0.2 to 15l/min
0.2 to 10l/min (normal usage) for concentrations >5 vol.%

Filling volume for anaesthetic agent:
About 340 ml with dry wick
About 300 ml with moist wick

Maximum angle of tilt
During transport (control dial at 0 ) any position and angle
During operation straight up

Warm up time: 5min

Mounting type:
Draeger plug in, selectatec compatible, cagemount (iso 23mm tapers),
Fix mount, cagemount with interlock

Filler type:
Pour fil, easy-fil (isofulrane, halothane, enflurane)
Pour fil, easy-fil, quik fil (sevoflurane)

Standard:
Ce, iso13485, iso9001, iso 8835-4, 93/42/eec mdd.
Oct-19-16
Supplier From Hefei, Anhui, China
 
Ar-325 anesthesia machine

Main body
High-strength engineering plastic rack, light,
Beautiful and corrosion resistant
Scope of application
Adult, child
Gas source
O2: 0.27--0.55mpa n2o: 0.27--0.55mpa
Flow meter
O2 : 0.1--1.0l/min 1.1--10l/min
N20: 0.1--1.0l/min 1.1--10l/min
Air : 0.1--10l/min
O2, n2o linkage and n2o stopper
When using nitrous oxide, oxygen concentration>25%;
When the oxygen pressure
Aug-18-21

Anesthesia Machine

$289
MOQ: Not Specified
Supplier From Guangzhou, Guangdong, China
 
Tidal Volume: 20-1500ml
Working Mode: Semi open, Semi closed or Closed system
Oxygen flush: 25L/min 75L/min
High light LED display
Oct-05-24

Anesthesia Machine

$7.50K
MOQ: Not Specified
 
Anesthesia Machine , Anesthesia workstation with two vaporizers and touch screen display. uses for infant, pediatric and adult application
Aug-01-14
 
Ce approved portable anesthesia machine
Compact light-weight and portable, could be transported by pull-rod case, put on table and assembly on the trolley.
Jackson or bains absorber is available
Specifically designed to accomodate low flow
Selectatec-bar and quick change vaporizer mounting device

Visible inspiration and expiration valve
Could upgrade to oxygen&n2o or oxygen&air flow meter freely
Module rack with polyester medical material with superior spray technology, high strength and light weight.
With transport case, convenient to take and transport
Easy to disassemble and assemble all the components, convenient for clean and maintenance.

Medical air compressor
Low noise medical air compressor, very stable performance, safe and reliable
Air compressor with lcd screen to display output pressure, provide safe, secure and permanent motivation
Compact design and easy to transfer
Assembled with clean control module, supplying cleaner and safer air to the patients
Effective sound-absorbing materials
Oil-free compressor with temperature protection
Match with various ventilator of international standard in the world


Size

Weight
Dec-07-11
 
Special Feature:

Application: Adult, Pediatric
Driven mode: Pneumatically driven electronically controlled
Mode: Semi-open, Semi-closed or closed system
Anesthetic vaporizer: One vaporizer

Anesthesia Ventilator:
Display: High light LED display
Ventilation mode: IPPV and Manual mode
Tidal Volume: 50 ~ 1600ml
Breath frequency: 1 ~ 90BPM
I:E ratio: 4:1 ~ 1:6
Monitor parameter: Tidal volume, breath frequency, MV, Airway pressure
Alarm: MV high alarm, MV low alarm, TV high alarm, TV low alarm

Main Unit:
Circle absorber: Compact circle absorber
Bellow: 50 ~ 1600ml
Oxygen FLUSH: 25L/min ~ 75L/min
Flow meter:
O2, N2O two-tube flowmeter
O2 tube: 0L/min ~ 10L/min
N2O tube: 0L/min ~ 10L/min
O2 and N2O linkage device
Adjust O2 and N2O in proportion ( keep O2 concentration not lower than 25% )
Gas source pressure:
O2: 0.25 ~ 0.65Mpa
N2O: 0.25~ 0.65Mpa
Gauge: 2 units, one N2O, one O2.
Dec-07-11
 
ARIES 2500 Anesthesia Machine:

Display: 10.4 TFT color screen
Application: Adult, Pediatric
Driven mode: Pneumatically driven electronically controlled
Mode: Semi~open, Semi~closed or closed system
Anesthetic vaporizer: two high precise vaporizers
Power supply: 220V,10%, 50Hz,1Hz
10V,10%, 60Hz,1Hz
Internal battery: DC12V (4 working hours)
Fresh gas outlet is in front of frame

Anesthesia Ventilator:
Respiration mode: IPPV, VCV, PCV, SIMV, SIGH, MANUAL, STANDBY, DEMO
Waveform: P-t, F-t, V-t, F-v, V-p
Tidal Volume: 20~1600ml
Respiratory frequency: 1~65bpm
I:E ratio: 4:1~1:4
Inspiration pause: 0~55%Ti Inspiration Pressure: 1~60cmH2O Trigger Pressure: -20~20cmH2O
Monitoring parameters: O2 concentration, MV, Respiratory frequency, Tidal volume, Ppeak, PEEP, I:E ratio, Pmean, Compliance etc..
Alarm parameters:
high pressure alarm, low pressure alarm, O2 concentration alarm, MV alarm, O2 source failure alarm, AC power failure alarm, etc.
Pressure alarm setting:
High pressure alarm set 1~60cmH2O.
Low pressure alarm set 0~20cmH2O
O2 concentration alarm setting:
high: 21~99%.
Low: 21~50%.
MV alarm setting:
MV high alarm set 10~99L/min
MV low alarm set 0~40L/min

Main Unit:
Circle absorber: Compact circle absorber

Flow meter:
Five~tube flow meter O2 tube: 0L/min~1L/min~10L/min.
N2O tube: 0L/min~1L/min~10L/min.
Air tube: 0L/min~10L/min
O2 and N2O Linkage Device, keep oxygen concentration not lower than 25%
Oxygen flush: 25L/min~75L/min

Gas source pressure:
O2: 0.25Mpa~0.65MPa
N2O: 0.25Mpa~0.65MPa
Air: 0.25Mpa~0.65MPa
Gauge: 4 units, 2¡ÁO2£¬N2O, Air.
Apr-09-24

Optimum 3G Anesthesia Machine

$5.00K
MOQ: Not Specified
 
3 Gas (Oxygen, N2O & Air) Anesthesia Machine
7" Touch Screen Display
Frame made up of MS Powder Coated
Tidal Volume - 50-1500 ML
Modes - CMV. ACMV, SIMV, PLV, Bag & Standby
PEEP & FiO2 Monitoring
2 Hours battey back up
Feb-22-22
 
The Anesthesia machine makes a good performance in Intensive Care Units (ICU), Operation room, Anesthesiology Department and other departments. From high to low acuity, simple to complex cases, pediatric to geriatric patients, Superstar Medical Anesthesia Systems offer you the choices you need in ventilation, monitoring and technique. whatâ??s more, our expertise in anesthesia delivery and ventilation is based on rich 23-year history of developing anesthesia solutions that meet your needs. Good performance based on High Security, High Accuracy, High Stability and accurate monitoring.

Verification Status