Please click here to check who's online and chat with them.

Casing Of Transformer

Supplier From China
Jun-26-17

Casing of Transformer
Casing of Transformer
Product Introduction
It is not necessary for general dry-type transformer to equip casing, means the protective degree is IP00, if need to be equipped with casing, protective degree is IP20, Casing is constituted by a safety shield to prevent accidental electrocution. Under the conditionof having dripping water, the transformer can be equipped with casing of that protective level is IP23. According to users  special requirements, we can provide casing with IP54 protective level.
Temperature Controlling and Cooling Devices
Temperature controlling device

Transformer adopts BWDK temperature controlling device, temperature measuring component is in the top of low voltage winding that can detect automatically and cyclically display working temperature of three-phase winding. When the temperature of winding reaches setting value , thermometer can automatically start the fan, stop the fan, signal transfer output, tripping output, etc.
Air cooling device
Transformer is equipped with dedicated Axial flow cooling fan, transformers capacity can be increased by 40%, even more under the condition of forced- air cooling.

Price and Minimum Quantity

Price: $100000
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Casing Of Transformer

Aug-05-16
 
MBO Series (9 frames) perfect designed plastic case current transformer, advanced snap on body, high accuracy (up to Class 0.2S),
humanization transparent cover and lead seal hole design makes the CT very easy to indentify after long term use and perfect
anti-stealing electricity.
Features
1:Safe, easy to install, portable
2:Wide inner window, allowing clamping of big cables or bus-bars
3:Wide range of sizes to accommodate all the existing installations
Applications:
1:Current measurement, monitoring and protection for electrical wiring and equipment.
2:Current and power measurement for electric motors, lighting, air compressor, heating and ventilation system, air-condition equipment and automation - control system.
3:Current, power and energy monitoring device.
4:Relay protection device.
Aug-05-16
 
ABO Series (8 frames) perfect designed plastic case current transformer, advanced snap on body, high accuracy (up to Class 0.2S),
humanization transparent cover and lead seal hole design makes the CT very easy to indentify after long term use and perfect
anti-stealing electricity.
Features
1:Safe, easy to install, portable
2:Wide inner window, allowing clamping of big cables or bus-bars
3:Wide range of sizes to accommodate all the existing installations
Applications:
1:Current measurement, monitoring and protection for electrical wiring and equipment.
2:Current and power measurement for electric motors, lighting, air compressor, heating and ventilation system, air-condition equipment and automation - control system.
3:Current, power and energy monitoring device.
4:Relay protection device.
Apr-11-14
Supplier From Shenzhen, Guangdong, China
 
Isolation transformer is used for low-voltage distribution system, isolate load from power, reject stray common mode and dc voltages, ground loop potentials, electromagnetic interference (emi) and radio frequency interference (rfi) from
Dielectric strength: l-l, l-g 4000vac/50hz/60s. Free of arcing breakage
I se is less than 65db (to be measured at the point 1 meter away from the reactor horizontally) .
Protection class: ip00 or as customer required.
Insulation class: h
Environment exists without gas, steam, chemical deposition, dust or dirt that will affect transformer¡¡¥s insulation seriously, explosive or corrosive medium is not allowed.
Standard: iec726:1982 dry power transformer , gb6450-86(equivalent to iec726:1982)


Standard carton or wooden case to the custom made transformer
Mar-09-22
 
Dongfang Yoyik Engineering Co., Ltd is specialized in producing, manufacturing and selling industrial spare parts, as well as providing products of famous brands. Since 1989, our products have being widely used in various industries from power, oil, chemical, electronic, gas to environmental protection, fire-fighting equipments and nuke industry.

YOYIK provides multiple types of spare parts and equipments for power plant :
#DF-Transformer SG-100VA-DF
Thrust bearing of gear box HPS663
thermocouple k-type temperature sensor TE-104
thermocouple WRN2-239 0-600â??
pump coupling 100LY-62
thermocouple k type WRNK2-231-R1/4\K
O-ring
temperature thermocouple WRNK2-332
axial piston variable pump 2.5CY14-1B
lubricating oil pump 2CY-2/0.6
Packing B05-8076Z-06TS
rotary vacuum pump ROTARYPUMP NO.30-WS SEARIAL
reciprocating piston pump PV292R5DC00
Filter element ZLT-50Z06707.63.08
thermocoupl 1000â?? TE-104
pressure hose SMS-20/N1/4-3048mm-C
RTD WZPM2-08-67.5-M18-B
Triple probe KR939SB3
centrifugal pump IS80-50-200
vacuum filter P-1762
Servo Valve SM4-20(15)57-80/40-10-S182-A
thermocouple types TKWRE2-230T �?6
vaccum pump ZS-185
oil transfer gear pump YW50-32-250A
screw pump working DLZB820-R64A-01
vacuum filter P-1761-1
hydraulic motor 65AY50X6
pt100 rtd probe thermowell WRNK2-292
actuator piston ring CV125-7
thermocouple machine WRNK2-231-R1/4\K
thermocouple machine WRNK-321
thermocouple range WRK2-001
vacuum cleaner 150LY-23-B
check washer JB/ZQ4347 30*80
screw pump manufacturer HSND280-43NZ
Platinum-Rhodium Wire WRKT2-11
piston plunger pump PV29-2R50C00
Transformer SG-100VA
vacuum pump oil ACF090N5ITBP
thermocouple wire TC03A2-KY-2B/S19
electric oil transfer pump HSNH120-46
thermocouple temperature sensor WRNK-322
thermocouple protection tube TC03A2-KY-2B/S20
sealing ring HB4-56J8-50
vacuum pump oil 30-WS-COML
LP Control Valve Position Sensor A3000TD-B15-C01
servo valve 760A185A
Fuse 6.6kV XRNM1-7.2/100
ksb pump centrifugal DFB80-50-20
vacuum pump parts P-1751
heater thermocouple TE-204
thermocouple k type TE-209
axial piston variable pump PV29-2R50-000
VALVE ,PC DUMP
Needle Valve SS-12NBSW8P
BFP oil system Diaphragm valve jtk113
thermocoupl 1000â?? WRNK2-0901T �?5
EH oil station cooling pump
k-type thermocouple TC03A2-KY-2B/S3
end suction centrifugal pump DFB80-80-240
Platinum Thermocouple Wire TC03A2-KY-2B/S15
oil pump cost 50FSB-30
centrifugal pumps head DFB-80-300
pt100 thermocouple WRK2-001
DEH CONTROL CARD
O-ring
thermocouple voltage WPNKZ-630
Spare Part Kit DN200/M3231
relief valve 2â?³LOF-98H
Casing Nash TC-31, 101
Transformer SG-100VA

DFYL-2022-3-9-ZYR
Apr-11-14
Supplier From Shenzhen, Guangdong, China
 
Sikes offers a complete line of industrial control transformers, which provide stepped-down voltages to machine tool control devices.
It¡¡¥s specifically designed to meet high inrush industrial applications where electromagnetic components such as relay, solenoids and magnetic motor starters are used.
Technical parameters

Insulation class: h
Environment exists without gas, steam, chemical deposition, dust or dirt that will affect transformer¡¡¥s insulation seriously, explosive or corrosive medium is not allowed.
Standard: iec726:1982 dry power transformer , gb6450-86(equivalent to iec726:1982)


Standard carton or wooden case based on the custom made product.
Jan-22-13
 
230-242kv on-load-tap-changing power transformer is made of high-quality silicon-steel sheets, and laminated by steps. It is advantageous in low loss, low noise, low voltage partial discharge and high anti short-circuit capacity. The dynamical and thermal stability of this transformer, of which the coils are winded by high-quality oxygen-free copper wire as well as used pre-compressing brackets processes and interior and exterior structure. The transformer tank used wave form shell, has very nice appearance, the core is with d shape yoke and 45 angle seaming. The core and oil box are well fixed and well protected on moving.

Packed in wooden case
May-22-20
 
DC immune Current transformer for Electricity meter

-Adopted high permeability core, high accuracy , good linearity;
-Anti-combustion plastic case ;
-Encapsulated with epoxy resin with strong insulation ability;
-DC immune function with good DC error , conform to IEC 62053-21;
- Customised shield to against the external magnetic field .
Mar-23-21
 
Three-phase transformers are used to convert the available 3-phase mains voltage into any load voltage.
To cater for the wide range of application areas involved,these transformers are essentially available in
the same kinds of designs as the single-phase transformers, e.g.
Three-phase dry-type transformer:
separate winding version
Three-phase series transformer:
autotransformer winding version
Three-phase safety, isolating, mains or
insulating transformer: separate winding version
In terms of how the 3 coils are connected, there are various options available and each of these provides
the transformers with specific properties. The vector group code is composed of the following elements:
The upper-case letter indicates the higher-voltage winding
(the highest voltage in terms of operation).
The lower-case letter indicates the lower-voltage winding.
The brought-out neutral is indicated by means of N or n
(depending on voltage level).
â?¢ The distinctive number indicates the phase angle of the lower voltage
in relation to the higher voltage (distinctive number multiplied by 30).
The following winding connection options are available
Delta: D, d
Wye (or star): Y, y
Zigzag: Z, z
Example: Dyn5
Higher-voltage winding is delta-connected.
Lower-voltage winding is star-connected with a brought-out neutral.
The lower voltage lags behind the higher voltage by 150�° (5 x 30�°).
Unless specifically requested otherwise, the transformers are configured with a double-star connection
and a brought-out neutral (vector group Yyn0); for autotransformers the vector group is YNa0.
Our three-phase transformer range includes all our standardised types for the 25 30.0 kVA performance range and a frequency of 50/60 Hz
Mar-18-13
 
Rectifier transformer is a transformer which used as the source of rectifier equipment. And primacy side of rectifier transformer connected with AC power is called line side, and secondary side connected with rectifier is called valve side.
Our company use the advanced techniques and manufacturing process, and with domestic colleges and universities to develop a number of research projects. Using procedural design, insulation breakdown mechanism, the electric field numerical analysis and insulation technology, the impact of characteristics and anti-sudden short-circuit strength of winding, the loss of eddy current filed calculation are analyzed and calculated. With manufacturing experience on rectifier transformer for many years, our company has got major break-though on the basis of the traditional calculation, which will further improve the reliability and advancement of products.
Features about rectifier transformer:
1.The rectifier transformer load is non-linear impedance, and valve side windings of rectifier transformer would get the currents which contain fundamental and other high-order harmonic superposition. And line side also gets corresponding non-sinusoidal currents connected by rectifier circuit coupling method.
2.According to different requirements of various customers, the valve side of rectifier transformer has a variety of special coupling method, such as: dual-back-star with inter phase reactor, three-phase bridge, star-delta parallel, six-phase bridge by inter phase reactor.
3.To improve power factor and reduce the line side harmonic currents of high-power rectifier equipments, rectifier transformer is needed to use star-delta winding phase displacement, phase-shift windings by phase displacement, autotransformer phase displacement, to improve the number of pulse of rectifier equipment.
4.According to the user¡¡¥s process requirements, the rectifier transformer line side voltage is required (such as 220kV) straight down to a very low valve side voltage (such as 1kV). The valve side voltage of rectifier transformer is required within a wide range of on-load tap from 5% - 105%. Auto voltage regulator and main theme of unity, string variable voltage regulator and other ways are used in rectifier transformer to achieve the purposes of a wide range voltage.
5.Self-saturable reactor can be used to change over and stabilize voltage in order to smooth rectify voltage. And some use silicon control to regulate voltage.
6.Valve side current of high-power rectifier equipment is very large, reaching 100kA and even greater. To improve power factor and avoid partial overheating and uneven distribution of current rectification components, it¡¡¥s required the technology of reverse-phase parallel.
7.With the wide application of AC frequency control technology, newly developed three-crack drive rectifier transformer came into being. And the lower voltage valve side of this transformer cracked into three independent branches, which can be made to supply for three different load power, which achieve ¡¡ã multi functional ¡¡À effect, reducing loss and saving area.
8.In order to reduce the large current in the fuel tank and other structures caused by loss, the rectifier transformer used magnetic shielding technology and so on.
A number of 220kV and below and different kinds of rectifier transformers have been manufactured for the general industrial, electrochemical electrolysis, transmission, traction frequency, variable frequency power supply, DC power transmission and other industrial sectors over ten years, and got the user¡¡¥s high praise. Recently, the 220kV level on-load-tap rectifier transformers supporting the country¡¡¥s largest 600 thousand project of caustic soda is done, and got the high praise of users.

fumigation wooden case

Verification Status