Please click here to check who's online and chat with them.

Modulating Capacity Transformer

Supplier From China
Jun-26-17

Modulating Capacity Transformer
Special Transformer
Modulating capacity transformer is one kind of distribution transformers, which has two capacities ( one is small , another one is large) and can adjust according to the load size. The changing of high voltage winding connection mode, the conversion of low voltage winding parallel series and the adjustment of every connection are finished by special no excitation modulating capacity switch. Meanwhile, when large capacity is adjusted to small capacity, no-load loss and no-load current will be reduced because the increasing of low voltage turns and the decrease of coreâ??s magnetic flux density reduce unit loss of silicon steel, thus reaches the purpose of lowing loss and energy-saving. Double voltage distribution transformer has one small and one large voltage, and can adjust according to electric grids voltage. The conversion of high voltage winding parallel series and the adjustment of every connection are finished by special no excitation modulating capacity switch.  
General introduction 
SZ11-T load modulating capacity transformer is one kind of distribution transformers with new technology and energy-saving. It has two kinds rated capacity, one is small and another one is large, and the operation mode of these two capacity can be automatically converted which solves the problem of transformersâ?? large loss caused by relatively large changes of 10 kV distribution grids seasonable magnitude, and also solve the operational maintain problem because capacity must be adjusted by hand after the outage of no-load modulating capacity transformer power . Modulating capacity transformer not only suits rural electric grids which seasonable magnitude changes are relatively large, but also suits downtown, development zones, industrial zones and other distribution work area where circadian load changes are obvious.
 Working principle
Load modulating capacity transformer is adjusted by the intelligent controller externally modulating- switches, thus completing the convert process of high capacity and low capacity, more details as below: intelligent controller determines the current load size by detecting transformers voltage and current of low voltage side; determines related constraints based on the capacity setting value; if meet the setting conditions, intelligent controller will issue the corresponding control commands to load modulating capacity switch, then modulating capacity switch can finish the star ,angle change and the parallel series convert of transformer s inner high voltage winding, low voltage winding; completes the process of capacity adjustment under conditions with power.

Price and Minimum Quantity

Price: $100000
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Modulating Capacity Transformer

Mar-11-19
 
Transformer Capacity and Loss Tester
Transformer Oil Tester

I  Introduction
Transformer Capacity Testing Instrument is specialized in bad power users evading basic electricity secretly adds capacity problems and is a high precision instrument specially used for the measurement of the transformer capacity and parameters. This product uses color LCD monitor, English display, simple and quick menu operation, man-machine interface is friendly. The internal of the instrument has a rechargeable battery and it can work without external power source. A fully charged battery can be continuously measured more than 100 sets. In addition, the instrument can provide three-phase precise 50Hz sine wave AC test power without the external three-phase test power, the pressure regulator, up flow reactor and other auxiliary equipment in measuring the capacity and transformer load loss, thus greatly improving the efficiency of the work.

This is a multi-functional measuring instrument, which is equivalent to two common devices: activity transformer capacity tester and transformer parameter tester. It can be used for test transformer capacity, model, no-load current, no-load loss, load loss, impendence voltage and so on.

This product has many advantages such as small, light , high accuracy, stability, simple operation and so on. It can replace the multi-meter method to measure the transformer loss and capacity with simple wiring and convenient testing so that the work efficiency can be greatly improved.

Function

1. We can measure a variety of distribution transformer, power transformer capacity instead of the additional power. It is more convenient and efficient.

2.Combined with the power, voltage, boost up flow and other equipment, it measures various transformer no-load current, no-load loss, impedance voltage, load loss and so on.

3.All results are automatically carried out relevant correction. You only need to input the related parameters (such as temperature, load adjustment coefficients), then the instrument can automatically correct such as waveform deformity correction, temperature correction, correction of non rated voltage, rated current correction.

4.The maximum voltage is up to 750V and the maximum current is up to 100A. It is equipped with protection circuit.

5.The voltage and current range can be very flexible and easy to expand.

6.It has large screen, high brightness LCD display, English menu and operation tips, friendly man-machine interface and wide temperature, brightness adjustable type LCD screen, which can adapt to the different temperature.
May-29-21

Transformer Capacity Load No-Load

$770 - $15.40K
MOQ: Not Specified
 
Product Introduction
This product is specially used for measuring the capacity of distribution power transformer measuring the no-load and short-circuit loss of transformer and has the function of harmonic analysis which is convenient for analyzing the quality of on-site power network. The device can automatically check whether the wiring is correct and display the vector diagram of the three-phase current and voltage when testing the three-phase transformer. At the same time necessary correction (such as waveform correction temperature correction unrated voltage correction calibration unrated current correction) is introduced to make the test results more accurate.

Product name Transformer capacity test instrument transformer capacity load tester
Jun-15-21
 
Single Phase, Double Wound Transformer Capacity - BRAND - VIJAYANTA, INDIA
1. Single Phase, Double Wound Transformer
Capacity : 1 KVA, 2 KVA.
VERIFIED
Sep-09-22
Supplier From Visakhapatnam, Andhra Pradesh, India
 
Control transformers are mostly used for industrial applications where electromagnetic devices are used such as solenoids, contactors and relays. Also control transformers can be utilized in industrial electrical applications for regulating voltages through electrical and electronic circuits.

We make wide range of control transformers with E-I Lamination core and with various termination styles to suit for customer applications either single phase or Two phase or Three phase as per customer requirements . We provide termination with lead wires, terminal blocks, Din rails, solder points, screws, and terminal connectors. We can provide EI transformers up to 10kVA. We can provide with electrostatic shields, Thermal protector switches and circuit breakers.

Features
Insulation Class as per UL/IS (A,B,F,H)
C and L clamps are provided according to specifications.
High quality Terminal blocks are provided.
High quality XLPE leads wires used.
Low loss EI stampings used for high efficiency.
High quality hardware used.
Glass filled Nylon Bobbins used.
Flame retardant insulation tapes used inside.
High quality insulation used.
Fiber glass sleeves used for external wires.
Compact in space
Cost effective
Particularly well suited for resin cast
Less in weight
UL Approved

Standards
We follow IS11171.
Compatible to IEC61558-1
We can provide UL 5085-1 and UL 5085-2

Applications
Used in converters, inverters, instruments and power supplies.
Used in many types of machines and accessories.
Used in electronic sensing circuits.
Used in voltage stabilizers.
Used in power conditioning equipments.
Used in Rectified Modules
Apr-09-07
Supplier From Xi'an, Shaanxi, China
 
Piezoelectric transformer

Piezoelectric transformer
Dec-10-21

Transformers

$770 - $15.40K
MOQ: Not Specified
 
Product Introduction
Capacitive voltage transformer (CVT) in calibration the test must be conducted under the condition of 50Hz frequency complex geographical condition on site at the same time the traditional experiment device is difficult to meet the requirements of on-site handling testing series resonance booster device is first used in domestic field tunable resonance device has been widely used in domestic 500 kv and below the field calibration of capacitor voltage transformer.



Product Parameters
Technical parameters
Rated Capacity 80kVA
rated voltage 160kV
Adjustable inductance range 65~130H
Rated frequency 50Hz
Rated current 0.5A
Adjustable gap range 0~300mm
Jul-15-10
Supplier From Ludhiana, Punjab, India
 
We can supply
Distribution transformer from the range 10
Kva to 3000kva 33 kv class and power
Transformer from 1000 kva to 5000kva 33 kv
Class


Depend supon capacity
Jul-04-07

Pad Mounted Transformer

$3.00K - $16.00K
MOQ: Not Specified
Supplier From Sn.Luis Soyatlan, Mexico
 
Pad mounted transformer

Capacities: 15kva - 2, 500kva
Voltages up to 34.5kv
Delta - wye, wye-wye
Zig-zag, scott-t
Aug-10-12
 
The busway is used for the electricity transmission from the electric power transformer to the main distribution screen or from the main distribution screen with a current transmission capacity of 3000a.


Product details

Verification Status