Please click here to check who's online and chat with them.

O2S-T6-Sh Long Probe Zirconia O2 Sensors

Supplier From China
Jun-24-17

Zirconia o2 sensors
Probe series - long housing

Features
* zirconium dioxide (zro2) sensing elements
* long life, non-depleting technology
* integral heating element
* high accuracy
* requires an external interface board to operate

Benefits
* no reference gas required
* no need for temperature stabilisation
* two lengths available; 220mm and 400mm

Technical specifications
Heater voltage
Operating: 4v dc ± 0.1v dc (1.7a)
Standby: 1.65v dc (0.7a)
Pump impedance at 700'c: < 6k
Permissible gas temperature
Standard temperature: -100'c to +250'c
High temperature: -100'c to +400'c
Gas flow rate: 0 - 10 m/s
Repetitive permissible acceleration: 5g
Incidental permissible acceleration: 30g

Output values
Oxygen pressure range: 2mbar - 3bar max
Accuracy: 5 mbar max
Internal operational temperature: 700'c
Response time (10 - 90% step): < 15s
Warm up time (prior to sensor operation): 100s
Warm up time (from stand by): 20s
Output stabilisation time: ~ 180s

Price and Minimum Quantity

Price: $1
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: O2S-T6-Sh Long Probe Zirconia O2 Sensors

Jun-02-17
Supplier From Shenzhen, Nanshan, China
 
Zirconia O2 Sensors
Probe Series - Long Housing

FEATURES
* Zirconium dioxide (ZrO2) sensing elements
* Long life, non-depleting technology
* Integral heating element
* High accuracy
* Requires an external interface board to operate

BENEFITS
* No reference gas required
* No need for temperature stabilisation
* Two lengths available; 220mm and 400mm

TECHNICAL SPECIFICATIONS
Heater voltage
Operating 4V DC ± 0.1V DC (1.7A)
Standby 1.65V DC (0.7A)
Pump impedance at 700'C < 6kohm
Permissible gas temperature
Standard temperature -100'C to +250'C
High temperature -100'C to +400'C
Gas flow rate 0 - 10 m/s
Repetitive permissible acceleration 5g
Incidental permissible acceleration 30g

OUTPUT VALUES
Oxygen pressure range 2mbar - 3bar max
Accuracy 5 mbar max
Internal operational temperature 700'C
Response time (10 - 90% step) < 15s
Warm up time (prior to sensor operation) 100s
Warm up time (from stand by) 20s
Output stabilisation time ~ 180s
Jun-23-17
Supplier From Shenzhen, Nanshan, China
 
Zirconia o2 sensors
Miniature series

The miniature zirconium dioxide oxygen sensors can be pcb mounted and are used when measuring ambient gas with the complete sensor immersed in the atmosphere which is to be measured.

Features
* zirconium dioxide (zro2 ) sensing elements
* long life, non-depleting technology
* integral heating element
* high accuracy
* requires an external interface board to operate

Benefits
* no reference gas required
* no need for temperature stabilisation
* pcb mountable

Technical specifications
Heater voltage
Standard response sensor: 4v dc â± 0.1v dc (1.7a)
Standby: 1.65v dc (0.7a)
Fast response sensor: 4.35v dc â± 0.1v dc (1.85a)
Standby: 2v dc (0.85a)
Pump impedance at 700'c: < 6k
Permissible gas temperature: -100'c to +250'c
Gas flow rate : 0 - 10 m/s
Repetitive permissible acceleration: 5g
Incidental permissible acceleration: 30g

Output values
Oxygen pressure range: 2mbar - 3bar max
Accuracy: 5mbar max
Internal operational temperature: 700'c
Response time (10 - 90% step)
Standard response sensor:
Jun-24-17
Supplier From Shenzhen, Nanshan, China
 
Zirconia o2 sensors
Flange mounted series

The flange mount zirconium dioxide oxygen sensor is designed for easy sealing into a manifold or sampling chamber. Favoured by ssts aerospace customers and in applications that require high temperature and pressure operation.

O2s-fr-t4-4p flange zirconia o2 sensors features
Zirconium dioxide (zro2) sensing elements
Long life, non-depleting technology
Integral heating element
High accuracy
Requires an external interface board to operate

O2s-fr-t4-4p flange zirconia o2 sensors benefits
No reference gas required
No need for temperature stabilisation
Flange mounting

O2s-fr-t4-4p flange zirconia o2 sensors technical specifications
Heater voltage
Operating: 4.35vdc ± 0.1vdc (1.85a)
Standby: 2vdc (0.85a)
Pump impedance at 700'c: < 6k
Permissible gas temperature: -100'c to +400'c
Gas flow rate: 0 - 10 m/s
Repetitive permissible acceleration : 5g
Incidental permissible acceleration: 30g

O2s-fr-t4-4p flange zirconia o2 sensors output values
Oxygen pressure range: 2mbar - 3bar max
Accuracy: 5mbar max
Internal operational temp: 700'c
Response time (10 - 90% step): < 4s
Warm up time (prior to sensor operation): 60s
Warm up time (from standby): 20s
Output stabilisation time: ~ 180s
GOLD Member
VERIFIED
Oct-19-20
Supplier From Seoul, South Korea (Republic Of Korea)
GOLD Member
VERIFIED
Jul-12-24
Supplier From Mumbai, Maharashtra, India
Dec-02-16
Supplier From Shenzhen, Guangdong, China
 
Features
* oxygen pressure range 2 mbar - 3bar
* zirconium dioxide (zro2 ) sensing elements
* non-consumption technology
* integral heating element
* no need for temperature stabilisation
* no reference gas required
* high accuracy
* linear output signal
* operates with external interface boards
* 80mm, 220mm and 400mm probes available

Specifications
Heater supply*
Porous lid cap 4v dc +/- 0.1v dc (1.7a)
Stand by 1.65v dc (0.7a)
Full porous cap 4.35v dc +/- 0.1v dc (1.85a)
Stand by 2v dc (0.85a)
GOLD Member
Jul-07-25
Supplier From Anyang-si, Gyeonggi-do, South Korea (Republic Of Korea)
GOLD Member
VERIFIED
Aug-09-25

Temperature Sensor Accessories, A1/A2

$0.05 - $1 / Piece (FOB)
MOQ: Not Specified
Supplier From Jamnagar, Gujarat, India
 
Temperature Sensor Accessories are essential components that support the accurate, safe, and efficient operation of temperature sensing devices such as RTDs, thermocouples, thermistors, and digital sensors. Designed for industrial, commercial, and laboratory use, these accessories enhance sensor performance, ensure reliable signal transmission, and protect the sensor in harsh environments.

â?? Key Features:
Compatible with RTD, thermocouple (K, J, T, etc.), and digital temperature sensors
Designed for easy installation, calibration, and maintenance
Made from durable materials like brass, stainless steel, aluminum, or plastic
Withstands high temperatures, corrosive media, and vibration
Available in custom thread sizes, cable lengths, and mounting styles
Ensures signal integrity and sensor protection in field conditions

ð??§ Available Accessories Include:
Thermowells â?? Protective sleeves for sensors in high-pressure/temperature environments
Compression Fittings & Adaptors â?? Secure and leak-proof sensor mounting
Terminal Heads & Enclosures â?? Weatherproof and explosion-proof housings
Cable Glands & Bushings â?? Secure wire entries with strain relief
Mounting Brackets & Flanges â?? For stable and accurate sensor placement
Connectors & Extension Cables â?? For signal transmission and modular installation
Ceramic Beads & Insulators â?? For high-temperature applications

ð?? ï¸? Applications:
Industrial automation and process control


Power generation and utility monitoring
Chemical and pharmaceutical manufacturing
Food processing and thermal mapping
Laboratory and scientific instrumentation
Dec-01-17
Supplier From Shenzhen, Guangdong, China
 
O2-M2 Oxygen Sensor Description
Alphasense Oxygen sensors use capillary flow control.

Unlike partial pressure oxygen sensors, they have good pressure and temperature dependence, making them the best choice in safety applications.

Standard galavanic sensors use lead for greatest reliability but fixed lifetime.

Specifications
* Output: 80 to 120 uA @ 20.9% O2
* Response time t90: < 15 (s) from 20.9% to 0% O2


* Linearity: 0.6 % O2 deviation @ 10% O2
* Operating life: > 24 months
*Temperature range: -30 to 55 'C
* Pressure range: 80 to 120 kPa
* Humidity range: 5 to 95 % rh continuous
* Diameter: 20.0 mm (including label)
* Heigh: 17.4 mm (including foam ring)
* Weight: < 16g

Verification Status