INTRODUCTIONS
I- GENERAL CHARACTERISTICS

Transformers immersed in insulating fluid with natural self cooling (ONAN), three-phase, 10 - 20 MVA.for indoor or outdoor use, 50/60 Hz, hermetically sealed.

II- MANUFACTURING STANDARD
The transformers described in this catalogue are designedand tested in accordance to IEC/BSEN 60076

III- RATINGS
30,50, 80,100,125,160, 200,250, 315, 400, 500, 630, 800, 1000, 1250, 1600, 2000, 2500kVA.

IV- HIGH VOLTAGE
This material is designed for voltages of â?¤ 36 kV. Specific figures are not given for this parameter because of the wide variety of voltagesused. Transformers can be supplied on demand to run at two different primary voltages, the shift between these input voltages has two basic alternatives:
with a primary tap changer which can be switched with no load and no applied voltage
or by changing terminals under the cover.

V- LOW VOLTAGE
The secondary voltage under no load is allocated at 400V, 415V, 433V, though other voltages can be supplied on demand. When usage requires two voltages, transformers with two simultaneous voltages can be supplied. In this case the no-load voltages are set to 400V(230V),415V(240V),433V(230V).

VI- VECTOR GROUP REFERENCE
The connections normally used are as follows:
For rated power levels of 160 kVA or less: Yyn0
For rated power levels over 160 kVA: Dyn11.

ACCESSORIES

I- BASIC EQUIPMENTS
All transformers are supplied with:
3 high voltage bushings
4 or 7 low voltage bushings
5-position tap changer on cover, workable with transformer off load
2 lifting & tank removal eye-bolts
Filling hole with M-40 x 1.5 outside thread and threaded cover
Drainage & sampling plug at bottom of tank
Two-way, standard rail gauge welded at the bottom of tank
2 earthing connections at bottom with M-10 screws

II- OPTIONAL ACCESSORIES
Thermometer
Tap changer
HV plug-in bushing
Thermostat
Protection & control block for the following

Price and Minimum Quantity

Price: $4000
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: High Voltage Oil Immersed Transformer

Jun-03-17
 
Title goes here.
INTRODUCTIONS
I- GENERAL CHARACTERISTICS

Transformers immersed in insulating fluid with natural self cooling (ONAN), three-phase, 10 - 20 MVA.for indoor or outdoor use, 50/60 Hz, hermetically sealed.

II- MANUFACTURING STANDARD
The transformers described in this catalogue are designedand tested in accordance to IEC/BSEN 60076

III- RATINGS
30,50, 80,100,125,160, 200,250, 315, 400, 500, 630, 800, 1000, 1250, 1600, 2000, 2500kVA.

IV- HIGH VOLTAGE
This material is designed for voltages of â?¤ 36 kV. Specific figures are not given for this parameter because of the wide variety of voltagesused. Transformers can be supplied on demand to run at two different primary voltages, the shift between these input voltages has two basic alternatives:
with a primary tap changer which can be switched with no load and no applied voltage
or by changing terminals under the cover.

V- LOW VOLTAGE
The secondary voltage under no load is allocated at 400V, 415V, 433V, though other voltages can be supplied on demand. When usage requires two voltages, transformers with two simultaneous voltages can be supplied. In this case the no-load voltages are set to 400V(230V),415V(240V),433V(230V).

VI- VECTOR GROUP REFERENCE
The connections normally used are as follows:
For rated power levels of 160 kVA or less: Yyn0
For rated power levels over 160 kVA: Dyn11.

ACCESSORIES

I- BASIC EQUIPMENTS
All transformers are supplied with:
3 high voltage bushings
4 or 7 low voltage bushings
5-position tap changer on cover, workable with transformer off load
2 lifting & tank removal eye-bolts
Filling hole with M-40 x 1.5 outside thread and threaded cover
Drainage & sampling plug at bottom of tank
Two-way, standard rail gauge welded at the bottom of tank
2 earthing connections at bottom with M-10 screws

II- OPTIONAL ACCESSORIES
Thermometer
Tap changer
HV plug-in bushing
Thermostat
Protection & control block for the following
Jun-30-21

Ac High Voltage Testing Transformer

$770 - $15.40K
MOQ: Not Specified
 
Pproduct brief introduction

AC hipot tester series Testing Transformer is power plants power supply bureau and research institutions and other users to do the AC voltage test basic test equipment by the standards of the State Bureau of Quality Supervision for a variety of electrical products electrical components insulation material dielectric strength test etc. the insulation level assessment of products under the provisions of the voltage insulation defects were found in the sample and measure the ability of over-voltage.

AC HV Testing Transformer Classification:
There are four kinds of high voltage testing transformer according to the medium points:
1. Oil-immersed high voltage transformer test: large capacity cheap convenient maintenance mainstream products.
2. Inflatable high voltage test transformer : interrupter resistance and light weight.
3. Dry type high voltage testing transformer: light weight light volume can run backward price expensive.
4. Series type high voltage testing transformer: small volume low voltage light weight easy to transport and install.
May-25-21
 
product brief introduction

AC hipot tester series Testing Transformer is power plants power supply bureau and research institutions and other users to do the AC voltage test basic test equipment by the standards of the State Bureau of Quality Supervision for a variety of electrical products electrical components insulation material dielectric strength test etc. the insulation level assessment of products under the provisions of the voltage insulation defects were found in the sample and measure the ability of over-voltage.

AC HV Testing Transformer Classification:
There are four kinds of high voltage testing transformer according to the medium points:
1. Oil-immersed high voltage transformer test: large capacity cheap convenient maintenance mainstream products.
2. Inflatable high voltage test transformer : interrupter resistance and light weight.
3. Dry type high voltage testing transformer: light weight light volume can run backward price expensive.
4. Series type high voltage testing transformer: small volume low voltage light weight easy to transport and install.
Jun-23-22

Oil Immersed Transformer 500Kva

$8.00K
MOQ: Not Specified
Supplier From Ha Noi, Alabama, Viet Nam
 
Product specifications
Rated power: 2500kVA
Voltage: 22/0,4kV
Winding connection: Dyn11
No-load loss (Po): 1850 W
Short-circuit loss(Pk): 21000 W
Max. no-load current(I0): 1.5%
Short circuit voltage(Uk ): 6%
Standard: : TCVN 6306 (IEC 60076); Decision 62 / Q EVN (Vietnam), ISO 9001:2015; ISO 14001:2015 (International).
Dec-26-19
 
main parameter of  69kv CT
Rated current ratio: 2000/1600/1500/1200/1100/800/500/400/300 : 5 A
Rated output capacity of each corresponding ratio: 200/160/150/120/110/80/45/35/25 VA
Winding accuracy class: 0.2/5P20/5P20/5P20 
CNMEs business activities cover national and international engineering, Generation Stations, Electrical Engineering Equipment, all kinds of electrical equipment, Test And Design and so on. The activities consist of the industries of high voltage power transmission and distribution, diesel power generation, thermal power generation, Transformer Test Laboratory Design, Electrical Lab Design And Solution, Power Plant Design and so on.
Aug-05-22

Oil Immersed Testing Transformer

$770 - $15.40K
MOQ: Not Specified
 
Product description

The test transformer calls the booster, it is the basic test equipment used by the power station, supplying and distributing the electrical power system and the scientific research unit. Which used in the insulated intension test on all kinds of electrical products, electrical equipments and insulated materials, testing the insulated level of products, discovering the insulated objection of quizzee, scaling the capacity burdened voltage

Oil Immersed Testing Transformer 1

Technical index

Model

Capacity


High Frequency Voltage Output Voltage
High Frequency Voltage Output Current )

Low Frequency Voltage input

Change

Tempera- ture raised

30 minute

V

A

1.5

50

30

200

7.5

500

10
3

50

60

200

15

500

10

5

50

100

200

25

500

10

10

50

200

220/380

50/26

500

10
Apr-28-22

Oil Immersed Testing Transformer

$770 - $15.40K
MOQ: Not Specified
 
Product description

The test transformer calls the booster, it is the basic test equipment used by the power station, supplying and distributing the electrical power system and the scientific research unit. Which used in the insulated intension test on all kinds of electrical products, electrical equipments and insulated materials, testing the insulated level of products, discovering the insulated objection of quizzee, scaling the capacity burdened voltage

Oil Immersed Testing Transformer 1

Technical index

Model

Capacity



High Frequency Voltage Output Voltage

High Frequency Voltage Output Currentm)

Low Frequency Voltage input

Change

Tempera- ture raised

30 minute

V

A

YD G1.5

1.5

50

30

200

7.5

500

10

YD G 3

3

50

60

200

15

500

10

YD G 5

5

50

100

200

25

500

10

YD G10

10

50

200

220/380

50/26

500

10

YD G 20

20

50

400

380

53

500

10

YD G 30

30

50

600

380

79

500

10

YD G 40

40

50

800

380

105

500

10

YD G 50

50

50

1000

380

132

500

10
GOLD Member
Mar-01-24

Transformers

$20
MOQ: Not Specified
Supplier From Ludhiana, Punjab, India
 
Transformers,Distribution and Power Transformer,Varivolt
Safety Transformers
Diesel Generators
Industrial Panels
Stabilizers
Energy Saver
Industrial Panels
Jan-20-22
 
Product description

The test transformer calls the booster, it is the basic test equipment used by the power station, supplying and distributing the electrical power system and the scientific research unit. Which used in the insulated intension test on all kinds of electrical products, electrical equipments and insulated materials, testing the insulated level of products, discovering the insulated objection of quizzee, scaling the capacity burdened voltage

Oil Immersed Testing Transformer 1

Technical index

Model

Capacity



KVA

High Frequency Voltage Output Voltage

KV

High Frequency Voltage Output Current mA)

Low Frequency Voltage input

Change

Tempera- ture() raised/

30 minute

V

A

YD G -1.5

1.5

50

30

200

7.5

500

10

YD G 3

3

50

60

200

15

500

10

YD G-5

5

50

100

200

25

500

10

YD G10

10

50

200

220/380

50/26

500

10

YD G20

20

50

400

380

53

500

10



30

50

600

380

79

500

10


40

50

800

380

105

500

10



50

50

1000

380

132

500

10



100

100

100

500

263

1000

10


150

100

1500

500

300

1000

10



200

100

2000

500

400

1000

10

Verification Status