Scope
Determination (drinks) volatile organic compounds, blood alcohol content detection, detection of indoor air pollutants (TVOC), flavor liquor composition analysis, transformer oil analysis, testing, high-purity gas analysis of residual solvents in pharmaceuticals, medical devices remaining in Determination of ethylene oxide.
Chromatograph units are mainly used: liquor factory, other wineries, petrochemical, gas liquefaction plant, the coal industry, environmental testing, inspection station, Forensic Center, the public security system, food plants, quality inspection departments, water plants, pharmaceutical plants, detection of pesticide plants, gas plants, chemical plants, packaging plant, paint factory, honey factory, chemical engineering universities and other trace ingredients are required to use gas chromatography, liquid chromatography

Features
1. Large-screen LCD English display. Easy to learn.
2. With self-diagnosis, over-temperature shutdown protection, file storage, recall, fifth-order temperature-programmed functions, with single-column automatic compensation function; to ensure the stability of the baseline temperature programmed analysis.
3. Instrument has dual packed column inlet capillary column three, three gas independent way.
4. With six independent temperature control area, after intelligent door systems, cooling is very fast; each of the gasification chamber, detector and amplifier are modular design, installation is very easy to replace.
5. Complete with a separate capillary analysis system, an independent capillary split sampler (includes a diaphragm cleaning, split and tail blowing conditioning). Optional capillary split / splitless injector.
6. Instrument equipped with a flame ionization detector, thermal conductivity detector, a flame photometric detector, electron capture detector, NPD five kinds of detectors, three detectors can be installed, the user can according to their own self-analysis requires optional , also increase the six-way injection valve, reformer devices; and to achieve detector series and parallel work.

Technical Parameters
Temperature Indicators
1. Temperature Area: column oven, injector, detector
2. Temperature range: room temperature on 5 ? ~ 450 ? (Increment 1 ?)
3. Temperature accuracy: better than ± 0.1 ?
4. Temperature program: Eight-order rate of 0.1 ? ~ 40 ? / min (increments of 0.1 ?)

Price and Minimum Quantity

Price: $3589
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Gc Transformer Oil Gas Chromatograph

GOLD Member
Mar-14-17
Supplier From Boston, MA, United States
GOLD Member
VERIFIED
Nov-13-18
Buyer From Singapore, Singapore
GOLD Member
VERIFIED
Apr-06-20
Buyer From Giza, Giza, Egypt
GOLD Member
VERIFIED
Sep-10-15
Buyer From Dombivli East, Maharashtra, India
GOLD Member
Feb-27-12
Supplier From Minneapolis, Minnesota, United States
GOLD Member
Sep-21-10
Supplier From Karachi, Sindh, Pakistan
GOLD Member
Jul-29-19
Buyer From Ho Chi Minh, Viet Nam
GOLD Member
Feb-23-20
Buyer From Singapore, Singapore
GOLD Member
Apr-20-21
Supplier From Johannesburg, Gauteng, South Africa

Verification Status