Please click here to check who's online and chat with them.

1250 Kva Cummins Generator

Supplier From United Arab Emirates
Oct-15-14

SET MODEL 1250KVA Prime at 50HZ,40? ambient 1000KW 1250KVA Standby at 50HZ, 40 ambient 1100KW 1375KVA Rated Gen-set output 230/400V 50HZ Rated Relative humidity 60%
Dimension(L×W×H) 5000×2200×2600mm Weight 8800kg

Fuel consumption 100% prime load 231L/h


Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: 1250 Kva Cummins Generator

GOLD Member
Oct-18-24
Supplier From Busan, South Korea (Republic Of Korea)
 
We have a stock of quality, low-life generators from the military
ï?¬ CAT 3408 400kW
ï?¬ CAT C-16 500kW
ï?¬ CAT 3406 350kW (House type)
ï?¬ Cummins VTA-28G5 500kW
ï?¬ Cummins LTA-10 250kW (House Type)
ï?¬ Cummins LTA-10 250kW
ï?¬ Cummins NT85-G3 350kW
ï?¬ Cummins NT85-G3 350kW (House type)
ï?¬ Cummins NT85-G2 300kW
Please study if it is suitable for your market.
Feb-27-25

Diesel Generator Sets - 1250 Kva

$250.00K
MOQ: Not Specified
Supplier From Dorohoi, Botosani, Romania
 
Cat DE1250 GC

Engine C32
Bore â?? mm (in) 145 (5.7)
Stroke â?? mm (in) 162 (6.4)
Displacement â?? L (in3) 32.1 (1959)
Compression Ratio 15.0:1
Aspiration TA
Fuel System EUI
Governor Type ADEMâ?¢ A4

Applicable Codes and Standards
AS1359, IEC 60034-1, ISO 3046, ISO 8528, 2014/35/EU, 2006/42/EC, 2014/30/EU, 2008 No. 1597, 2016 No. 1091, 2016 No. 1101 and 2001 No. 1701 amended by 2005 No. 3525
GOLD Member
Feb-21-25
Supplier From Busan, South Korea (Republic Of Korea)
 
We have 4sets of used Detroit generators that were used as emergency power sources (Standby only) at a municipal water drainage plant in Korea. Please review the attached documents and assess
ENGINE SPECIFICATION
ENGINE MODEL Detroit Diesel 8163-7416 1232HP
ENGINE NO. 16VF013546
RPM 1,800
Cylinder 16
Injection method Direct injection
Cooling method Water Cooled
Fuel consumption rate 246â??/h
GENERATOR SPECIFICATION (AC Generator, 3Ã??, 60Hz, Brushless type
Generator Model DIG 4800
Emergency output 990 kVA / 792 kW
Continuous output 900kVA / 720kW
Voltage and Current 600 v x 86.6 A
Revolution 1800RPM
Excitation Voltage/Current 65V/10A
Power Factor 80%
Insulation Class F
Oct-10-22
 
EAC 1000
Engine: CUMMINS
Engine Model : KTA38-G2A
Stand By kVA: 1000
Stand By kW : 800
Prime kVA: 909
Prime kW : 727
Rated Current : 1308

Engine
- CUMMINS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed

Alternat�¶r
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm

Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)

Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system

Engine CUMM�°NS
Engine Model KTA38-G2A
Number of Cylinders 12 - V TYPE
Injection System Direct
Compression Ratio 14.5:1
Bore 159
Strok 159
Displacement Lt 38
Air Intake Turbocharged, Aftercooled
Speed (RPM) 1500
Oil Capacity Lt 135
Standby Power kw / Hp 895 / 1199
Prime Power Hp 813 / 1089
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity Lt 350
Fuel Consumption (lt / h) Lt Full Load 202,3
Lt %75 LOAD 153,7
Lt %50 LOAD 103,1

Frequency Hz
Power kVA 825
Voltage V 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation �±1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8

Weight (Silent) Kg 9350
Weight (Open) Kg 8200
Width (Silent) Mm 2200
Length (Silent) Mm 6200
Height (Silent) Mm 2800
Fuel Tank Capacity Lt 1750

1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Oct-07-22
 
EAC 890
Engine: CUMMINS
Engine Model : KTA38-G2B
Stand By kVA: 890
Stand By kW : 712
Prime kVA: 809
Prime kW : 647
Rated Current : 1165

Engine
- CUMMINS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed

Alternator
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm

Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis

Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system

Engine CUMM�°NS
Engine Model KTA38-G2B
Number of Cylinders 12 - V TYPE
Injection System Direct
Compression Ratio 14.5:1
Bore 159
Strok 159
Displacement Lt 38
Air Intake Turbocharged, Aftercooled
Speed (RPM) 1500
Oil Capacity Lt 135
Standby Power kw / Hp 789 / 1057
Prime Power Hp 711 / 953
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity Lt 350
Fuel Consumption (lt / h) Lt Full Load 176,9
Lt %75 LOAD 133,3
Lt %50 LOAD 91,3

Frequency Hz
Power kVA 825
Voltage V 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation ±1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8

Weight (Silent) Kg 9300
Weight (Open) Kg 8150
Width (Silent) Mm 2200
Length (Silent) Mm 6200
Height (Silent) Mm 2800
Fuel Tank Capacity Lt 1750

1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Sep-27-22
 
EAC 825
Engine: CUMM�°NS
Engine Model : KTA38-G2
Stand By kVA: 825
Stand By kW : 660
Prime kVA: 750
Prime kW : 600
Rated Current : 1080
Engine
- CUMMINS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat�¶r
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine CUMM�°NS
Engine Model KTA38-G2
Number of Cylinders 12 - V TYPE
Injection System Direct
Compression Ratio 14.5:1
Bore 159
Strok 159
Displacement Lt 38
Air Intake Turbocharged, Aftercooled
Speed (RPM) 1500
Oil Capacity Lt 135
Standby Power kw / Hp 731 / 980
Prime Power Hp 664 / 890
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity Lt 350
Fuel Consumption (lt / h) Lt Full Load 167
Lt %75 LOAD 128
Lt %50 LOAD 90
Frequency Hz
Power kVA 825
Voltage V 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation ±1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 9250
Weight (Open) Kg 8100
Width (Silent) Mm 2200
Length (Silent) Mm 6200
Height (Silent) Mm 2800
Fuel Tank Capacity Lt 1750
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnot permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Jul-23-22
 
EAC 790
Engine: CUMMINS
Engine Model : KTA38-G1
Stand By kVA: 790
Stand By kW : 632
Prime kVA: 718
Prime kW : 574
Rated Current : 1033
Engine
- CUMM�°NS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat�¶r
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine CUMM�°NS
Engine Model KTA38-G1
Number of Cylinders 12 - V TYPE
Injection System Direct
Compression Ratio 14.5:1
Bore 159
Strok 159
Displacement Lt 19
Air Intake Turbocharged, Aftercooled
Speed (RPM) 1500
Oil Capacity Lt 135
Standby Power kw / Hp 701 / 953
Prime Power Hp 634 / 862
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity Lt 350
Fuel Consumption (lt / h) Lt Full Load 158
Lt %75 LOAD 122
Lt %50 LOAD 86
Frequency Hz
Power kVA 550
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation �±1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 9200
Weight (Open) Kg 8050
Width (Silent) Mm 2200
Length (Silent) Mm 6200
Height (Silent) Mm 2800
Fuel Tank Capacity Lt 1750
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Jun-17-22
 
EAC 495
Engine: CUMMINS
Engine Model : QSZ13-G3
Stand By kVA: 495
Stand By kW : 396
Prime kVA: 450
Prime kW : 360
Rated Current : 648
Engine
- CUMMINS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternator
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine CUMMINS
Engine Model QSZ13-G3
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 17:01
Bore 130
Strok 163
Displacement L 13
Air Intake Turbocharged,Air-Air Cooled
Speed (RPM) 1500
Oil Capacity L 40
Standby Power kw / Hp 470 /629
Prime Power kw / Hp 450 /603
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity L 60
Fuel Consumption (lt / h) L Full Load 101
L %75 LOAD 74,2
L %50 LOAD 49
Frequency Hz
Power kVA 385
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation ±1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 4100
Weight (Open) Kg 3625
Width (Silent) Mm 1600
Length (Silent) Mm 4500
Height (Silent) Mm 2400
Fuel Tank Capacity L 650
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
May-18-22
 
EAC 440
Engine: CUMMINS
Engine Model : NTAA855-G7A
Stand By kVA: 440
Stand By kW : 352
Prime kVA: 400
Prime kW : 320
Rated Current : 576
Engine
- CUMM�°NS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat�¶r
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine CUMM�°NS
Engine Model NTAA855-G7A
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 14.0:1
Bore 140
Strok 152
Displacement L 14
Air Intake Turbocharged,Air-Air Cooled
Speed (RPM) 1500
Oil Capacity L 38,6
Standby Power kw / Hp 407 / 545
Prime Power kw / Hp 370/ 500
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity L 60
Fuel Consumption (lt / h) L Full Load 89,2
L %75 LOAD 67,8
L %50 LOAD 47,5
Frequency Hz
Power kVA 385
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation �±1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 3765
Weight (Open) Kg 3290
Width (Silent) Mm 1600
Length (Silent) Mm 4500
Height (Silent) Mm 2400
Fuel Tank Capacity L 650
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.

Verification Status