ItemsUnitValue
Rated powerkw4600
Thermal efficiency%75
Design pressurempa1.1
Working pressurempa0.8
Furnace oil capacitym34.6
Oil circulationm3/h241
Connection pipe diametermm200
Size:L*W*Hmm7768*3300*6784
Reference weight t43.5

Price and Minimum Quantity

Price: $25000
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Heat-Conducting Boilers

May-03-14
 
ItemsUnitValue
Rated powerKw3500
Thermal efficiency%75
Design pressureMpa1.1
Working pressureMpa0.8
Furnace oil capacityM33.8
Oil circulationM3/h188
Connection pipe diameterMm200
Size:l*w*hMm7595*2925*5720
Reference weight T38
Apr-24-14
Supplier From Qingdao, Shandong, China
May-03-14
 
2938
Thermal efficiency % 170
Dust emission concerntration Mg/nm3 <80
Indentified thermal efficiency % 82.5

Max part size for transportation (l¡¡§¡éw¡¡§¡éh) Mm 10700*3550*3400
Max part weight for transporation cargo T 41
Installed exterior size(l¡¡§¡éw¡¡§¡éh) Mm 14000*4730*7820
Apr-28-14
 
ItemUnitData
Steam capacity T/h1
Nominal steam pressureMpa1.0/0.7
Nominal steam temperature¡æ184/170
¡¨¢1.8¡¨¢2.9
Max. Transport weightT11 13
Assembly size(lxwxh) m36.0¡¨¢3.2¡¨¢4.2
Draught fanAirflowM3/h3295-5100
PressureMpa2383-2079
PowerKw5.5
Blower fanAirflowM3/h1688-3517
PressureMpa792-1300
PowerKw1.5
Governing box powerKw0.55
Feed pumpFlow rateM3/h2.4
HeadM119/153
PowerKw3
Slag machine powerKw0.75
Apr-28-14
 
1;¨¢2.9¡¨¢3.6
Max. Transport weightT28
Assembly size(lxwxh) m36.8¡¨¢3.6¡¨¢5.1
Draught fanAirflowM3/h8868-19342
PressureMpa2805-3041
PowerKw18.5
Blower fanAirflowM3/h5360-10288
PressureMpa2582-1616
PowerKw7.5
Governing box powerKw0.55
Feed pumpFlow rateM3/h3.75-7.5
HeadM175/200/300
PowerKw7.5/11/15
Slag machine powerKw1.1
Apr-28-14
 
Item Unit


The coal consumption at full load operation (kg/h) 156
Thermal efficiency % 77.4
Dust emission concerntration (mg/nm3) 132.1
Apr-28-14
 
ItemUnit
Rated effluent pressure (mpa)0.7
Rated effluent water temperature Oc95
Rated return water  temperature Oc70

The coal consumption at full load operation (kg/h)364.32
Thermal efficiency %78.17
Max part size for transportation (l¡¨¢w¡¨¢h) Mm5.113*2.231*3.4
Max part weight for transporation cargo (t)18.5
VERIFIED
Sep-13-20
 
Each kind of castable refractory material serves a different purpose. Here are some examples as to how people would use them for different applications.





Conventional Dense Refractories. These have a high concentration of alumina cement in their composition. Conventional dense refractory materials can handle temperatures that go as high as 1800 Fahrenheit. Applications such as boiler work require these kinds of materials.


Insulating Materials. Another kind of castable refractory is the insulating kind. They are lower density compared to the other types of castable refractory materials. They have low thermal conductivity as well. They are a good choice if you want something that will resist abrasion.


There is such a wide range of refractory materials that you can choose from for their applications. Castable refractory materials also vary, so we advise calling in for a consultation. Our knowledgeable staff will be happy to help out.
GOLD Member
Jul-25-23
Supplier From Vadodara, Gujarat, India
 
Insulation Bricks are used for hot face & back up insulation lining of Boiler, Reheating furnace, Blast furnace, reactor chamber, high temperature furnace etc.

Insulation Bricks are providing energy efficiency by minimising heat loss. They have feature of low density, high purity, low thermal conductivity, excellent thermal shock resistance.

Types of Insulation Bricks:
Cold Face Insulation Bricks
Hot Face Insulation Bricks
HFK Insulation Bricks
Porosint Insulation Bricks

Sizes: Standard 9 * 4.5 * 3 Inch