SPECIFICATIONS:
Wavelength Range: 190-900nm
Wavelength Accuracy: ±0.25nm
Resolution: Two Spectral lines of Mn at 279.5nm and 279.8nm can be separated with the spectral bandwidth of
0.2nm and valley-peak energy ratio less than 30%
Baseline Stability:
Background correction: The D2 lamp background correction capability at 1A is better than 30 times.
!0.004A/30min.
Light Source:
Lamp turrel: 6-lamp turret RIC-114/ RIC-113
4-lamp turret RIC-112
Auto-alignment, fully automated scan and peak-picking
Lamp current adjustment: Automatic adjustment and display.
Wide pulse current: 0~25mA
Narrow pulse current: 0~10mA
Lamp power supply mode: 400Hz square wave pulse
100Hz Narrow square wave pulse + 400HzWide Square wave pulse (RIC-114/ RIC-113)
Optical System:
Monochromator: Single beam, Czurney-turner design grating monochromator
Grating: 1800l/mm
Focal length: 277mm
Blazed wavelength: 250nm
Spectral bandwidth: 0.1nm, 0.2nm, 0.4nm, 1.2nm automatic change
Flame Atomizer:
Burner: 10cm single slot all-titanium burner
Spray chamber: Corrosion resistant all-plastic spray chamber
Nebulizer: High efficiency glass nebulizer with metal sleeve, sucking up rate:6-7mL/min
Detection and Data Processing System:
Detector: R928 photomultiplier with high sensitivity and wide spectral range
Software:Windows Operating System
Analytical method:Window curve auto-fitting; standard addition method; automatic sensitivity correction, automatic
calculation of concentration and content.
Repeat times: Maximum 20 times of repeat measurement, automatic calculation of mean value, standard deviation
and relative standard deviation
Multi-task function: Sequential measurement of multi-elements in one sample
Condition reading:With model function
Result printing: Measurement data and final analytical report printout, editing with excel.
Standard RS-232 serial port communication
Characteristic Concentration and Detection Limit:
Normal Air-C H flame: Cu Characteristic concentration
Rich oxygen Air-C H flame: Ba: Characteristic concentration
Function Expansion: Hydride vapor generator can be connected for hydride analysis.
Dimensions and weight: 1020 (L) X 490 (W) X 540 (H) mm (main unit), unpacked 80 Kg.
Dimensions and weight: 1020 (L) X 490 (W) X 540 (H) mm (main unit), unpacked 80 Kg.
Supplier: Tungsten copper contact tips, copper tungsten tips, tungsten carbide tips, low voltage contact materials, pure metal contact materials, alloy contact materials(silver metal alloy, fine grain silver), midium voltage contact material(copper chromium, copper chromium iron), high voltage contact material(copper tungsten), a variety of custom contacts, materials include silver nickel, silver copper, silver tungsten, silver metal oxides alloy, silver cadmium oxide, silver tin oxide, silver cadmium oxide indium oxide, silver tin oxide indium oxide, silver zinc oxide, silver nonmetal alloy, silver graphite, silver tungsten carbide, silver tungsten carbide graphite, equipment for producing contact materials, such as grinders, grinding machines, edm machines, wire cutting machines and other equipment, as well as testing instruments for contact materials, including relays, contactors, vernier calipers, microscopes, hardness testers, atomic absorption spectrophotometers and other equipment.