Please click here to check who's online and chat with them.

Earth-Resistant Tester Etcr2000

Supplier From China
Jan-02-12

Features:
Widely applied in ground resistance measurement, loop resistance measurement
With optional function of RS232 interface data upload
No need to disconnect the ground wire from the ground net
Without auxiliary electrode
High accuracy and resolution
With data memory
Automatic power off

Specifications:
Clamp size: 65 x 32mm
Resistance range: 0.01 to 1,200ohm;
With automatic shifting
Resistance resolution: 0.001ohm;
Data memory: 99 sets
Alarm setting: 1 to 199ohm; and buzzer alarm
Quick boot: in 0.5 second
With lower consumption.

Price and Minimum Quantity

Price: $329.23
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Earth-Resistant Tester Etcr2000

May-26-09
 
Earth Resistance Tester:
Model: ETCR2100+(basal)
Category: Ground Resistance tester
Earth Resistance Tester (ETCR2100+)-Illustration:
ETCR 2100+ of Pincers Earth Tester, in the measurement of a grounding system with loop current, does not require breaking down the grounding wire, and need no auxiliary electrode. It is safe, fast and simple in use.
1.Wider range: 0.01Ñ+-1200Ñ+
2.Stored data: 99 groups.
3.Resistance Resolution: 0.01Ñ+
4.Size of Jaw: ¬¬32ú¿mmú¬
5. Sound and light alarm, "beep - beep - beep -" alarm sound.
6. Breakthrough in self-test the boot a long time to wait, start immediately into the test.
7. Breakthrough relay self-test mode, using the most advanced processing algorithms and digital integration technology, a fully intelligent.
8. Break the old product to heavy issues, more in line with characteristics of handheld devices.
9. The new design, panel 6 button operation, the performance through.
10. Lower power consumption: Maximum operating current not exceeding 50mA.




260*90*66(MM)
Jul-26-18
Supplier From Guang Dong, Guang Zhou, China
 
Main features:1. 2/3/4-wires measurement of earth resistance, soil resistivity, earth voltage, , ac voltage;, 2.Measurement range: earth resistance: 0.00î©-30.00kî©; 0~600v, soil, resistivity: 0.00î©m-9000kî©m; 3. Data upload: rs232 interface, 4.Date storage:300 sets, model no:mewoi4000c, name:mewoi4000c-earth ground resistance/soil resistivity tester, electrode distance range:can be set 1m-100m, low power consumption:standby:1. About 20ma (backlight shut off), 2.Boot and with backlight: about 45ma, (25ma without backlight), 3.Measurement: about 100ma, (backlight shut off)
Aug-22-08
 
Clamp on ground resistance tester

ETCR 2000C
*Accurate ground resistance measurement from 0.01to 1000Ohms
*current measurement including leakage current
*Accurate readings regardless of power quality in 1 seconds
*Simple and easy to use, no test leads or auxiliary electrodes necessary
*Data logging capability - 50 records
*Individual data point recording
*User selectable audible alarms
*Auto power off
*Low battery indicator
*Large LCD display

Ground Resistance: 0.010 - 0.099 Ohms (¿¬+ 1% ¿¬+ 0.01 Ohms, resolution 0.001 Ohms)
Ground Resistance: 0.10 - 0.99 Ohms (¿¬+ 1% ¿¬+ 0.01 Ohms, resolution 0.01 Ohms)
Ground Resistance: 1.0~49.9 Ohms (¿¬+ 1.5% ¿¬+ 0.1 Ohms, resolution 0.1 Ohms)
Ground Resistance: 50.0~99.5 Ohms (¿¬+ 2% ¿¬+ 0.5 Ohms, resolution 0.5 Ohms)
Ground Resistance: 100~199 Ohms (¿¬+ 3% ¿¬+ 1 Ohms, resolution 1 Ohms)
Ground Resistance: 200~395 Ohms (¿¬+ 6% ¿¬+ 5 Ohms, resolution 5 Ohms)
Ground Resistance: 400~590 Ohms (¿¬+ 10% ¿¬+ 10 Ohms, resolution 10 Ohms)
Ground Resistance: 600~1000 Ohms (¿¬+ 20% ¿¬+ 20 Ohms, resolution 20 Ohms)
Ground Leakage Current: 0.00~299 mA (¿¬+ 5% ¿¬+2 mA) resolution 1 MA
Ground Leakage Current: 100~299 mA (¿¬+ 5% ¿¬+5 mA) resolution 1 mA
Ground Leakage Current: 0.30~2.99 A (¿¬+ 5% ¿¬+0.03 mA) resolution 10 mA
Ground Leakage Current: 0.30~2.99 A (¿¬+ 5% ¿¬+0.03 mA) resolution 10 mA
Ground Leakage Current: 10.00~20.00 A (¿¬+ 5% ¿¬+0.5 mA) resolution 10 mA.
May-26-09
 
Specifications

Function AC leak currentú¼high-harmonic currentú¼0n line current testú¼phaseíóelectrical energyú¼power factor revise
Test mode Clip-onCT
Output mode Current mutual inductance output uA/mAú+mA/A or voltage output mV/mAú+mV/Aú¿lectotypeú¬
Dimensions Widthí-heightí-thicknessú¦64mmí-160mmí-23mm
Clamp mouth ª+40mm
Wire length 2.0mú¿by orderú¬
Measure range AC 1uAí½80Aú+10uAí½300Aú+10mAí½600Aú¿lectotypeú¬
Resolution 1uAú+10uAú+5mAú¿lectotypeú¬
Accuracy 1% ú+2%ú¿50Hzú+25íµí+3íµú¬ú¿lectotypeú¬
Linearity degree 1% ú+2%ú¿50Hzú+25íµú¬ú¿lectotypeú¬
Work frequency 10í½100KHz
Wire voltage Line test under AC600V
Quality About120g
Working temperature and humidity -25íµí½70íµú+below 80%rh
Storage temperature and humidity -10íµí½60íµú+below 70%rh
Insulation AC2kV/rms (between core and box)
Applicable safety rules IEC1010-1íóIEC1010-2-032íópollution, etc 2íóCAT ó=(600V).
May-26-09
 
Specifications
Function AC leak currentú¼high-harmonic currentú¼0n line current testú¼phaseíóelectrical energyú¼power factor revise
Test mode Clip-onCT
Output mode Current mutual inductance output uA/mAú+mA/A or voltage output mV/mAú+mV/Aú¿lectotypeú¬
Dimensions Widthí-heightí-thicknessú¦138mmí-42mmí-20mm
Clamp mouth ª+7.5mm
Wire length 2.0mú¿by orderú¬
Measure range AC 1uAí½10Aú+ 5uAí½20Aú+10uAí½50A
Resolution 1uAú+5uA ú¦10uAú+ú¿lectotypeú¬
Accuracy 0.1-0.2ú¿50Hzú+25íµú¬
Ungraded load í_50ª+
Work frequency 10í½100KHz
Wire voltage Line test under AC600V
Quality About175g
Working temperature and humidity -25íµí½70íµú+below 80%rh
Storage temperature and humidity -10íµí½60íµú+below 70%rh
Insulation AC2kV/rms (between core and box)
Applicable safety rules IEC1010-1íóIEC1010-2-032íópollution, etc 2íóCAT ó=(600V).
Jan-02-12
 
Features:
With latest patented technology
Safe and time saving: non-contact phase sequence detection
Multipurpose: with live wire examination,simple power inspection, phase deficiency judgment, breakpoints finding and line maintenance
Dynamic LED display
Sensitive and reliable.

Specifications:
Voltages: 70 to 600V AC
Dimensions to be clamped: diameter 18mm.
Jul-14-09

Earth Resistivity Meter

$3.00K
MOQ: Not Specified
Supplier From Pune, Maharashtra, India
 
Depth of Investigation v 400 meters

a. Transmitter

1) Constant Current Selected automatically depending on
ground conditions
Max. Current 500mA
Min. Current 1mA
2) Voltage (Max) 500 V (1000 Vpp)
3) Power 40W

b. Amplifier
Voltage Measurement
Input Impedance 10 M Ohm
Input Range 0-200V
Precision + 0.05 mV
Noise Rejection 95 dB at 50-60 Hz

c. Resistance Measurement
Apparent R Range m Ohm, Ohm, K Ohm
Apparent R Precision 0.02 m Ohm at 500 mA

d. System Data
Cycle time 12 seconds
Accuracy 2%
Diagnostic display 9 codes
Temp. Range 0 v 50 degree c

e. Power Source 12 Volt, 12 Ah Rechargeable Battery
Measuring capacity 2000 readings at 20 mA
200 readings at 500 mA

f. Weight 12.5 Kg

g. Dimensions L 400mm X W 225mm X H 330mm



Weight 20 kg of instrument Additional Accessaries 60-80 Kg.
Feb-10-12
 
Function and usage
It can set with 5 different temperature spots to do heat sealing, select the optimal heat healing temperature, and can also set the same temperature to speed up the heat sealing.
Instrument structure:
The structure of the heat-sealing tester is composed of 4 parts: pneumatic drive system, heat-sealing equipment, temperature adjustment system and time adjustment system.
Pneumatic drive system:
It includes pressure gauge, guide stick, cylinder, pneumatic valve, pressure regulating handle and so on. You can pull the pressure-regulating handle outward, rotate to the right side to adjust the heat sealing pressure to a high value, and rotate to the left side to reduce it. After setting the pressure, please press the handle to the side of mainframe to lock the air pressure.
Heating-seal device
It is composed of the upper and lower heat-sealing sticks, of which the upper one is connected with a cylinder. There is an insulating plate in the upper part, which can prevent heat transmit to the cylinder. The heat-sealing stick is made of aluminum, and the center is heater. There is a silica gel plate in the upper part of the lower heat-sealing stick, which can mitigate pressure impact during heat sealing. Temperature measurement system was installed at the back of the heat-sealing stick.
Temperature adjustment system:
The upper temperature controller controls the temperature of upper heat-sealing stick, and the rear temperature controller controls the temperature of lower heat-sealing stick. The temperature can be set at will through adjusting the button on the dial plate.
Time adjustment system:
Time adjustment system: The heat-sealing time can be set at will through adjusting the button on dial plate. The setting scope of time is 0.01s to 999.9h. Press the foot switch under the manual state, and the heat-sealing stick will be pressed together. Under the automatic state, the press-fitting time of upper and lower heat sealing sticks are controlled by a timer automatically, it can automatically recover later. The unit of timer is 0.1 second in general. There is time adjusting button on the panel of the timer, and the heat-sealing time can be adjusted at will.
Specifications
Power : AC220V 50HZ
Compressed air: 8kg/cm2
Heat sealing plane: 300mm10mm slick (With silicon pad in lower seal stick)
Heat sealing temperature: room temperature 20~300C (Precision 1C)
Heat sealing time: 0.01s~99.99h
Heat-sealing pressure: 0~0.8Mp.
Dimension: 700(L)mm400(W)mm540(H)mm
Weight: Desktop 30Kg.




700mm(L)X400mm(B)X540mm(H)
Aug-22-08
Supplier From Guangzhou, Guangdong, China

Verification Status