Please click here to check who's online and chat with them.

Single Phase Submersible Panel

Supplier From India
Oct-24-23

Mfg of single phase starter up to 3hp .. supplier of all starter spares

Price and Minimum Quantity

Price: $13
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Single Phase Submersible Panel

Feb-06-23
 
Submersible Pump Control Panel
Sep-09-22
 
Product description

Single-phase standard power supply is suitable for power department, quality control department, research units, institution of higher learning, electric energy meter, power supply management, load control, power quality, reactive power compensation device and production of the enterprise and so on. It can be as single phase voltage source, current source and power source.



Electrical parameters

Electrical parameters

Accuracy class

0.05%, 0.1%

Power supply

Single phase AC 85-265V, 50/60 Hz

AC Voltage output

Range

57.7V / 100 V / 220V / 380V, Switch automatically (max 500V)

Adjustment resolution

0.01%, 0.1%, 1%, 10%,



AC Voltage output

Range 57.7V / 100 V / 220V / 380V, Switch automatically (max

Adjustment resolution 0.01%, 0.1%, 1%, 10%,

Accuracy 0.05% RG

Stability Better than 0.01% RG/1min

Distortion degree Better than 0.1% (not capacitive load)

Load capacity 40VA

Full load regulation rate Less than 0.01% RG

Full load regulation time Less than 1ms

Temperature drift 8 PPM C

Long-term stability 60 PPM/year



AC Current output



Range



Adjustment resolution

Accuracy Stability

Distortion degree

Load capacity

Full load regulation rate

Full load regulation time

Temperature drift

Long-term stability

0.1A / 0.25A / 0.5A / 1A / 5A / 10A / 20A / 50A / 100A,

Switch automatically 0.01%, 0.1%, 1%, 10%,

0.05% RG

Better than 0.01% RG/1min

Better than 0.1% (not capacitive load)

40VA

Less than 0.01% RG Less than 1mS

8 PPM C

60 PPM/year
VERIFIED
Feb-14-23
 
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic.
Functional details
1. Hot plug
Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system.
2. Advanced current sharing technology
Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A.
3. Control of input limited power
Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode.
4. Control of output constant power
When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module.
The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V.
The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage.
5. Temperature limited power
6. Regulation of output current limiting point
8. Regulation of output voltage
The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc.
9. Fan control
The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module.
10. Protection of input overvoltage/ voltage shortage
11. Output overvoltage protection
The overvoltage protection point is 260Vdc ~770Vdc (�±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection.
12. Over-temperature protection
The environmental over-temperature protection point is 80�°C. When the DC panel has a temperature over 100�°C, the module will stop working; when the DC panel has a temperature below 90�°C, the module will automatically work again.
13. Protection of internal bus fault
When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on.
14. Short circuit protection
In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".
VERIFIED
Dec-05-23
 
Name: terminal block for single phase or three phase electricity meter
Material: PBT+Fiberglass, PC+fiberglass
Can be customized
VERIFIED
Nov-01-23
 
Meter Box, Meter Cabinet, Panel Box For Single Phase And Three Phase Electricity Meter
VERIFIED
Jun-20-22
Supplier From Rajkot, Gujarat, India
 
Cable Features - Special heat resistant insulation - Higher current carrying capacity. - Fine copper wires - Highly thermal stable insulation - Excellent resistant to moisture, abrasion, grace, oil - Long Life - Excellent mechanical & electrical properties Cable Standard IS : 694 : 2010 & BS 6004, BS EN 50525-2-31 Application Fixed installation in conduits and under plaster, for appliance wiring and distribution stations. Standard Packing Coils 90 and 180m Conductor Flexible Bare Copper conductor class-2 and class-5 as per IS: 8130 EN 60228 Insulation HR/FR/FRLS-H/ZHFR Insulation compound with a high insulation resistance value as per IS:5831 Color Red, Yellow/green, Blue, Black, Brown, Grey, Orange, White, Green, Yellow Properties PVC Self-extinguishing and flame retardant according to EN 60332-1-2
Dec-23-21
 
Product description

The Single phase capacitance and inductance tester is specially developed for the problem of measuring the capacitance value of the capacitor on the substation.



Technical parameters

Instrument measurement range and accuracy

Capacitance measurement

Measurable capacitance range 0. 1 F 3,300

Measurable capacity range 5 20,000kvar

Measurement accuracy 1.0 readings 0.02 F

Resolution 0.001 F

Current measurement

Current measurement range 0 20A

Measurement accuracy 3.0 readings 0.05A

Resolution 0.01A

Inductance measurement

Inductance measurement range

small inductance mode 0.1mH 5mH

large inductance mode 5 mH 50H

Inductive reactance measurement range 50m 20K

Measurement accuracy 3.0 readings 0.05mH

Resolution 0.01mH
Resistance measurement

Resistance measurement range

small resistance mode 50m 1
Jul-30-13
 
1. Capacitance: 1uf --100uf.

2. Rated voltage: 250vac / 370vac / 440vac / 450vac / 500vac

3. Operating temperature: -40 161;230;to +85161;230;

4. Operating frequency: 50/60hz

5. Endurable voltage (t-t): 1.75un/2.0un

6. Tangent of loss angle: 16110.0040(1khz)

7. Capacitance deviation: 161¡è5%

8. Out leads: wire or tabs

9. Specifications can be supplied according to the customers' special need.

10. Reasonable price and stable quality.
Jul-30-13
 
1. Capacitance: 1uf --100uf.

2. Rated voltage: 250vac / 370vac / 440vac / 450vac / 500vac

3. Operating temperature: -40 oc to +85 oc

4. Operating frequency: 50/60hz

5. Endurable voltage (t-t): 1.75un/2.0un

6. Tangent of loss angle: ¡¡§10.0040(1khz)

7. Capacitance deviation: ¡¡§¡è5%

8. Out leads: wire or tabs

9. Specifications can be supplied according to the customers' special need.

10. Reasonable price and stable quality.

For more information, please contact us.

Verification Status