Description
Two component Epoxy based anti corrosive primer containing zinc phosphate as corrosion inhibiting pigments
Recommended Use :-
It is recommended as primer on M.S surface for OEM's as well as for process industries like fertilizers, refineries, chemicals and other plants. It can also be applied in diverse areas of tank exteriors, equipments, pipelines, structural steel, etc. Not to be used for immersion application.
Physical Data :-
COLOUR :- Yellow
FINISH :- Matt
SOLIDS BY VOLUME :- 40 �± 3%
THEORETICAL SPREADING RATE :- 13.33 sq.mt. / ltr. at recommended DFT of 30 �µ
FLASH POINT :- Base : 23�°C Hardener : 23�°C
DRYING CHARACTERISTICS :- SURFACE DRY : 60 to 90 minutes
(At 30�°C & 65% Relative Humidity) :- HARD DRY : Overnight. FULL CURE : 7 Days
SHELF LIFE :- BASE : 6 months HARDENER : 6 months
SURFACE PREPARATION
Abrasive blasting to Sa 21/2 Swedish Standards is the best method of surface preparation. In case blasting is not possible, then the surface of steel should be cleaned to St-2/St-3 std. The surface should be absolutely dry, moisture and oil free before primer application
Application Data
MIXING RATIO :- Base : Hardener (As per our recommendation)
APPLICATION :- By Brush / By Conventional Spray / By Airless Spray
THINNER :- Epoxy Thinner 190
POT LIFE :- 4 hours min at 30�°C
RECOMMENDED DFT :- 30 - 40 �µ.
OVERCOATING INTERVAL :- MIN : 8 Hours MAX : 24 Hours
COMPATIBILITY :- Can be over coated with Epoxy, PU, Chlorinated rubber and Oleo-resinous topcoats.
Application Method
Stir the Base part thoroughly. Mix the base and hardener as per our recommended ratio, by volume. Stir the mix gently to attain homogeneity. Allow the mixture to stand still (maturation) for about 10-15 minutes to initiate the reaction. Add Epoxy Thinner into the mix, if required, depending on application method, and stir gently for few minutes. Strain the paint through Nylon filter cloth and apply uniformly over the surface. All equipments used for above should be properly cleaned. Application : By Brush / By Conventional Spray / By Airless Spray Generally no thinner is required for Brush application; however under adverse environmental conditions about 5% of thinner, by volume, can be added. . Apply evenly in crossed manner, ensuring the uniform application. Use quality brushes for paint application.
For Conventional Spray application:-
Thinner : Epoxy Thinner 190
Addition : 10-15%
Nozzle Orifice : 1.2 1.4 mm
Nozzle Pressure : 40 - 70 p.s.i.
For Airless Spray Application:-
Thinner : Epoxy Thinner 190
Addition : Max 5%
Nozzle Orifice : 0.37- 0.42mm
Nozzle Pressure : 1400-1800 p.s.i.
Supplier: Auto paints, industrial coatings, powder coatings