Please click here to check who's online and chat with them.

Co Sensor Tgs5141

Supplier From China
Feb-01-23

Description
TGS5141 is a battery operable electrochemical sensor which uses a unique electrolyte that eliminates the need for a water reservoir. By eliminating the water reservoir used in TGS5042, the comparative size of TGS5141 is reduced to just 10% of TGS5042. With its ultra compact size, this sensor is the ideal choice for size oriented applications such as portable CO detectors, small residential CO detectors, and multi-sensor fire detectors. OEM customers will find individual sensors data printed on each sensor in bar code form, enabling users to skip the costly gas calibration process and allowing for individual sensor tracking.



Features:

Ultra compact
Battery operable
High repeatability/selectivity to CO
Linear relationship between CO gas concentration and sensor output
Simple calibration
Long life
UL recognized component
Meets UL2034, EN50291, and EN54-31 requirements



Applications:

Residential and commercial CO detectors
Fire detection

Price and Minimum Quantity

Price: $0.1
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Co Sensor Tgs5141

GOLD Member
Jan-20-23
Supplier From Dhaka, Dhaka, Bangladesh
 
Honeywell BW Solo is a easy to service single-gas detector with BLE connectivity that provides real-time visibility into the status and safety of hazardous-area workers, helping companies respond faster, more knowingly and decisively to safety incidents. The first single-gas detector with the 1 Series sensor for CO, H2S and O2

Features & Benefits:
User-friendly operation,
Easy-to-read display for multiple languages,
Lightweight convenience,
Ease of maintenance,
Serviceability,
The new 1-Series sensor for enhanced reliability,
Connected Bluetooth Low Energy (BLE) capabilities.
Mar-13-19
Supplier From Shenzhen, Nanshan, China
 
CO/H2S-D2 Miniature Size Carbon Monoxide + Hydrogen Sulfide Sensor Introduction
The world wide use of multigas, portable, personal safety monitors has grown since the 1970s to include an ever increasing number of industries. The one requirement in common to the majority of these instruments is the need to measure both Carbon Monoxide and Hydrogen Sulfide simultaneously.

Alphasense now offers a compact, dual gas sensor which allows designers to reduce significantly instrument size and cost. The D2 sensor provides a unique approach to the dual gas sensor in both its size and working electrode configuration. The use of a high capacity filter over the Carbon Monoxide working electrode eliminates Hydrogen Sulfide cross sensitivity to Carbon Monoxide.

Proven in the field over many years, these sensors perform well even under long term, challenging conditions.

* Range: 1000 ppm CO limit of performance warranty
* Range: 100 ppm H2S limit of performance warranty
* Sensitivity: 27 to 55 nA/ppm in 400ppm CO
* Sensitivity: 90 to 160 nA/ppm in 20ppm H2S
* Response time t90: < 25 (s) from zero to 400ppm CO
* Response time t90: < 30 (s) from zero to 20ppm H2S @ 20 deg C
* Temperature range: -30 to 50 deg C
* Humidity range: 15 to 90 %rh continuous
* Pressure range: 80 to 120kPa
Oct-25-18
Supplier From Shenzhen, Guangdong, China
 
CO-BM Carbon Monoxide Sensor (CO Sensor) Description
Alphasense Carbon Monoxide gas sensors operate using proven fuel cell technology.

CO-BM Carbon Monoxide Sensor sizes:
32mm diameter package, the best choice for fixed site applications

The Alphasense family of CO sensors have proven themselves in the field with long term stability and reliable operation, well beyond the two-year warranty, using our patented electrode technology.

CO-BM Carbon Monoxide Sensor (CO Sensor) Specifications
* Range: 5,000 ppm limit of performance warranty
* Sensitivity: 80 to 130 nA/ppm in 400ppm CO
* Response time (t90): < 25 (s) from zero to 400ppm CO
* Resolution: < 0.5 RMS noise (ppm equivalent)
* Temperature range: -30 to 50'C
* Pressure range:80 to 120KPa
* Humidity range: 15 to 90 % rh continuous
* Weight: < 13g
Sep-20-18
Supplier From Shenzhen, Guangdong, China
 
CO-AF Carbon Monoxide Sensor (CO Sensor) Description
Alphasense Carbon Monoxide gas sensors operate using proven fuel cell technology.

CO-AF Carbon Monoxide Sensor (CO Sensor) sizes:
20mm diameter, the industry standard size for portable gas detectors

The Alphasense family of CO sensors have proven themselves in the field with long term stability and reliable operation, well beyond the two-year warranty, using our patented electrode technology.

CO-AF Carbon Monoxide Sensor (CO Sensor) Specifications
* 20mm diameter
* Sensitivity: 55 to 90nA/ppm in 400ppm CO
* Response time t90: < 25s from zero to 400ppm CO
* Resolution: < 0.5 RMS noise (ppm equivalent)
* Range: 5,000ppm CO limit of performance warranty
* Temperature range: -30 to 50'C
* Pressure range: 80 to 120kPa
* Humidity range: 15 to 90% rh continuous

Matched Transmitter board for CO-AF CO Sensor
4-20 mA Digital Transmitter Board
* Factory calibration, custom-set for immediate use
* Digital zero, sensitivity and temperature compensation
* Digital and 4-20mA output
* Biased or unbiased operation
* Calibration and range change
Sep-13-18
Supplier From Shenzhen, Guangdong, China
 
CO-AM Carbon Monoxide Sensor (CO Sensor) Description
Alphasense Carbon Monoxide gas sensors operate using proven fuel cell technology.

CO-AM Carbon Monoxide Sensor sizes:
20mm diameter, the industry standard size for portable gas detectors

The Alphasense family of CO sensors have proven themselves in the field with long term stability and reliable operation, well beyond the two-year warranty, using our patented electrode technology.

CO-AM Carbon Monoxide Sensor (CO Sensor) Specifications
* Range: 5,000 ppm CO limit of performance warranty
* Sensitivityâ??: 55 to 90 nA/ppm in 400ppm CO
* Response time t90: < 25 (s) from zero to 400ppm CO
* Resolution: < 0.5 RMS noise (ppm equivalent)â??
* Temperature range: -30 to 50'C
* Pressure range: 80 to 120kPa
* Humidity range: 15 to 90% rh continuous
* Weight: < 6 g
Aug-23-14
Supplier From Shenzhen, Guangdong, China
 
specifications:sensor: electrochemical carbon monoxide sensor
detecting range: 0-999ppm
sensitivity: 5ppm
error: ¡¨¤10% +15ppm
the detecting precision is affected by detector itself and the temperature and humidity of the installation environment
the best installation environment: 20
numerical readings and note: 3-digit lcd display of levels
normal reading: 0
alarm readings: 30 - 999ppm
battery capacity display: full, ok, low, dead
sensor performance display: malfunction
alarm modes: sound, beep, hummer
light: red led flashing
installation: wall and table
power supply range: 110/220/230-240v ac
backup battery: 1 x 9v alkaline battery
working temperature: 0 - 60¡ãc
relative humidity: <98% rh
static current: <0.3ma
alarm current: <100ma

•the responding time of this co alarm fully comply with the usa ul2034 specifications regarding sensitivity:co level (ppm):70ppm
150ppm
400ppm
700ppm

responding time range:60-180 minutes
10-50 minutes
4-15 minutes
2-6 minutes


•the responding time of this co alarm fully comply with the en50291 specifications regarding sensitivity:co level (ppm):50ppm
100ppm
300ppm
400ppm




16.4*8.9*3.6cm
Mar-06-14
 
L high reliability, low drift

Applications
L automotive pressure monitoring
L pneumatic gages
L hand-held meters
Mar-06-14
 
Introduction
Irm300 is one of the general ndir co2 gas modules, which adopting ndir principle, consists of carefully designed light chamber, precise electric circuit and intelligent software. With the help of single light source, dual channel detector, and
Unit
Storage temperature
Tstg
-20 to 80
¡ãc
Working temperature
Ta
0 to +50
¡ãc
Working humidity
Ha
0 to 90
% rh
Working pressure
Pa
0.8 to 1.2
Atm


Electric characteristics

Description
Symbol
Min.
Typical
Max.
Unit
Supply power
Vs
4.6
5
5.4
V
Maximum current
Imax

130
160-
Ma
Light current
Iavg

60
70
Ma
Frequency
F
0.2
1
2
Hz
Preheat time
Twarm
90
120
180
Sec

Performance characteristics
Description
Min
Typical
Max
Unit
Detection range
0
2000
50000
Ppm
Detection accuracy
-
¡¨¤60ppm¡¨¤5% fs
-
Ppm
T90
Diffusing
-
60
90
Sec
Pumping
-
10
20
Sec
Repeatability
Zero

<¡¨¤80

Ppm
50% fs
-
<¡¨¤8% fs
-

Lifetime
3
5
10
Year
Mar-16-22
Supplier From Wuhan, Hubei, China

Verification Status