Please click here to check who's online and chat with them.

Digital Fiber Spectrometer

Supplier From China
Aug-24-07

Stdfsm 3666 digital fiber spectrometer
Detector: toshiba tcd1304 ap linear ccd array
Detector wavelength response range: 200nm-1100nm (200nm-850nm or 350nm-1100nm)
Pixels: 3648
Pixel size: 8um*200um
Pixel well depth: 105 number electrons
Snr: 300:1 (full signal)
A/d resolution: 12 bit
Dark noise: 50 rms counts
Corrected linearity: 99.8%
Sensitivity (photon/count): 400nm:130, 600nm:60
Optical system: f/4, asymmetrical crossed czerny-turner
Focal length: 45mm (input), 70mm (output)
Entrance aperture: 5um, 10um, 15um, 20um, 50um width slits or fiber (customizable)
Grating: various kinds of scoring grating or holographic grating with different grating constants and flare wavelengths (customizable)
Cylindrical lens: optional
Optical filter: band pass or long pass filters to eliminate secondary spectrum
Fiber and fiber connection: na 0.22, sma 905 (customizable)
Wavelength range: depend on optical grating
Optical resolution: 0.2nm-10nm fwhm (depend on grating constant, width of slit and detector model)
Wavelength tolerance: about 0.2mm
Integration time: 10us-64s
Dynamic range: 2.0*108 (system), 1300:1 (single acquisition)
Stray light: < 0.05% at 550nm
Power consumption: 250ma*5 vdc
Data transfer speed: full spectrum into memory every 5ms at usb 2.0 (16ms at usb 1.1)


Standard

Price and Minimum Quantity

Price: Negotiable
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Digital Fiber Spectrometer

Aug-06-07
Supplier From Shenzhen, Guangdong, China
Jul-21-20
Supplier From Jakarta, DKI Jakarta, Indonesia
Aug-06-19
Supplier From Shenzhen, Guangdong, China
May-25-23
Supplier From Jakarta, DKI Jakarta, Indonesia
Mar-20-08
 
Spectrometer

1)peak value and quasi-peak value range: 20db¦v--130db¦v(9khz--150khz), 10db¦v--90db¦v(150khz--30mhz).
2)frequency scaning range: 9khz--150khz(band width:200hz), 150khz-30mhz(band width:9khz).
3)frequency scaning step length: 100hz/200hz/400hz/(9khz-150khz), 5khz/10khz/20khz (150khz-30mhz).
4)scaning interval: 50ms/100ms/200ms(9khz-150khz), 5ms, 10ms, 20ms(150khz-30mhz).
5)accuracy: ¦3 dbuv.
6)input resistance 50, max input signal:2v.
7)use 50/50¦h+5 single phase v-type simulative network according to cispr standard.
8)meet the testing requirement of fcc, en55015, en55022, gb17743, limit value freely set, for the convenience of customer.
9)windows xp pro and windows 2000 compatible software.



1)peak value and quasi-peak value range: 20db¦v--130db¦v(9khz--150khz), 10db¦v--90db¦v(150khz--30mhz).
2)frequency scaning range: 9khz--150khz(band width:200hz), 150khz-30mhz(band width:9khz).
3)frequency scaning step length: 100hz/200hz/400hz/(9khz-150khz), 5khz/10khz/20khz (150khz-30mhz).
4)scaning interval: 50ms/100ms/200ms(9khz-150khz), 5ms, 10ms, 20ms(150khz-30mhz).
5)accuracy: ¦3 dbuv.
6)input resistance 50, max input signal:2v.
7)use 50/50¦h+5 single phase v-type simulative network according to cispr standard.
8)meet the testing requirement of fcc, en55015, en55022, gb17743, limit value freely set, for the convenience of customer.
9)windows xp pro and windows 2000 compatible software.
Mar-20-08
 
Goniophotometric

1) auto range switch
2) function: luminous flux, luminance, illuminance.
3) fine v() and cos corrected detector, class 1 according to gb/t7403 standard
4) low zero drift, high accuracy
5) 5 digit display
6) accuracy of luminous intensity: class 1
7) rs-232-c interface

Hp200z-measurement accessories

Integrating spheres
1) internal diameters: 0.5m/1.0m/1.5m/2.0m
2) work with all instrument systems spectrometers

Photodetector
1) fine v()-approximation and cosine corrected.
2) accuracy: classa



1) auto range switch
2) function: luminous flux, luminance, illuminance.
3) fine v() and cos corrected detector, class 1 according to gb/t7403 standard
4) low zero drift, high accuracy
5) 5 digit display
6) accuracy of luminous intensity: class 1
7) rs-232-c interface

Hp200z-measurement accessories

Integrating spheres
1) internal diameters: 0.5m/1.0m/1.5m/2.0m
2) work with all instrument systems spectrometers

Photodetector
1) fine v()-approximation and cosine corrected.
2) accuracy: classa
Mar-20-08
 
Photometer

1) voltage output range: dc 6v/12v/24v/50v(auto range switch)
2) current output range: dc 0.1ma - 2.500a
3) current drift at full range: 0.05% reading/8 minutes
4) accuracy of a: (0.08% reading 0.02% range)



1) voltage output range: dc 6v/12v/24v/50v(auto range switch)
2) current output range: dc 0.1ma - 2.500a
3) current drift at full range: 0.05% reading/8 minutes
4) accuracy of a: (0.08% reading 0.02% range)
Mar-20-08
 
Spectrometer

1)meet the requirements of gb & cie
2)tested luminaires installation with cross laser aiming
3)intelligent photodetector with fine v(d) correction
4)photometric accuracy: first-grade standard
5)angle accuracy: ¦0.2¦
6)testing optical distance: 0.5m, 1m, 1.6m
7)range of effective intensity: 0.1lx - 30, 000lx
8)spread angle of light beam: (50%), (75%), (25%)
9)measuring data can be applied for lighting design by other lighting softwares
10) rs-232c interface, based on window sxp/2000
Mar-20-08
Supplier From Hanzhou, China

Verification Status