Ig module is damaged due to poor heat dissipation


The frequency converter makes a sudden sound during operation, and the external connection is burned. It is found that the IGBT module of the frequency converter is damaged after disassembly. Through the test of relevant boards, it is found that the IGBT trigger circuit is damaged, and other plates are normal. When removing the frequency converter board, it was found that there were a lot of oil and dust on the power board and current detection board. Turn on the fan of the heat sink of the frequency converter and see that the heat sink is also covered with oil and sundries, which completely blocks the heat dissipation channel of the frequency converter. It is inferred that the Ig module of the frequency converter is damaged due to poor heat dissipation.


Maintenance process: first, completely disassemble the frequency converter, remove the heat sink of the heat dissipation channel, clean the heat sink with air pressure gas, and clean all the internal structural parts and boards of the frequency converter. Install the IGBT module. When installing the IGBT module, install it in sequence according to the requirements of the module, with appropriate torque. Repair the trigger circuit, and then install other devices in turn. After installation, conduct static test. After the static test results are good, conduct power on test and load test. The on load test is qualified and the maintenance is completed successfully.


Experience summary: Based on the maintenance of several frequency converters in different models and different use environments, it is concluded that the main reason for the damage of frequency converter IGBT module is the poor use environment, which leads to the damage of electronic components on gate drive card and the blockage of heat dissipation channel of frequency converter* The easily damaged devices are voltage stabilizing tube and optocoupler. Check whether there is a problem in the driving circuit. Compare whether the resistance of each trigger terminal is consistent when power is off. The voltage waveform at the trigger end can be measured after power on. However, some frequency converters cannot be started without being installed into the module. At this time, a false load is connected in series at the p-end of the module to prevent the module from being burnt out due to touching the originator or other lines by mistake during inspection.

Price and Minimum Quantity

Price: $400
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Integrated Automation Device 2C0683 Abb

GOLD Member
VERIFIED
Nov-21-20
Supplier From New Delhi, Delhi, India
GOLD Member
Jul-05-24
GOLD Member
Nov-27-24
Supplier From Shenzhen, China
GOLD Member
Feb-18-21
 
Product description

VFD for biomass burner, biomass gasification burner. For electric cabinet frequency and voltage converting, to meet different countries voltage. Ensure the bioamss burner can work well.
GOLD Member
VERIFIED
Oct-19-20
Supplier From Seoul, South Korea (Republic Of Korea)
GOLD Member
VERIFIED
Jul-12-24
Supplier From Mumbai, Maharashtra, India
GOLD Member
Sep-07-21
Supplier From Hui Zhou, Guang Dong, China
GOLD Member
Jun-25-25
Buyer From Ankara, Cankaya, Turkey
GOLD Member
VERIFIED
Jun-17-25

Brushless Ats Automated Diesel Generator Sets, 1

$1.00K - $10.00K / Box (FOB)
MOQ: 1  Boxes
Sample Available
Supplier From Weifang, Kuaiwen, China
 
Manual start/stop mode - Electronic control panel selects manual mode, one key to start, one key to stop.
Automatic start-stop mode - electronic control panel AUTO one-key automation; utility power outage automatic start,
utility power incoming automatic shutdown.
Emergency stop mode - The unit is equipped with an external emergency stop button safety device, realising one-key stop in emergency.
Backup Start Mode - Car type key ignition start.
Note: To avoid the failure of the electronic control panel to start the unit
and add the standby type double insurance start, in the emergency power outage needs
to use the generator set is more secure!

Translated with DeepL.com (free version)

Verification Status