Special features and strong points
-material : nitinol(nickel+titanium), shape memory property
-anti-migration shape
-flexible construction to conform to anatomy
-dynamic radial force for maximum lumen size
-retrievable
-each of two radiopaque markers at both ends of stent
Material: nitinol(nickel+titanium), shape memory property.
Anti-migration shape
Flexible construction to conform to anatomy
Dynamic radial force for maximum lumen size
Retrievable
Each of two radiopaque markers at both ends of stent
Used :- For temporary internal drainage from the ureteropelvic junction to the bladder.
Caution:- Periodic evaluation is advised. Polyurethane T-Flex / soft-Flex .
Intended for one time use.
This Device is Supplied sterile in peel-open packages.
The EvroPlus Evrolimus eluting stent system is a combination product comprised of two regulated components : a device (a coronary stent system) and a drug product (a formulation of Everolimus contained in a polymer coating) pre mounted a balloon catheter between two GOLD radio opaque marker bands.
Strut Thickness (m) : 60±5
With XIENCE Sierra's new stent design, the XIENCE reputation now extends to offer unmatched deliverability, even with challenging complex lesions.
ULTRA LOW STENT CROSSING PROFILE1 OF 0.039â?³
FOR EASIER CROSSING
enabled by the new stent design and balloon technology1
XIENCE Sierra's exceptional deliverability also comes from the enhanced stent delivery system featuring a single-piece outer member for added pushability and trackability.
Expanded Treatment Optionsâ?¡
With 5.5 mm post-dilatation capability for 3.5 mm and 4.0 mm stents, XIENCE Sierra can treat most large vessels.
PROVIDES UNSURPASSED PRECISION IN PLACEMENT AND AVOID GEOGRAPHIC MISS
zero shortening even at max expansion of 5.5 mm2
XIENCE SIERRA ENSURES COATING INTEGRITY3
even at max expansion
XIENCE Sierra
coating remains intact at maximum post-dilatation expansion
of 5.5 mm from 3.5 mm
XIENCE Sierra (3.5 x 18 mm)
25x magnification at max expansion
of 5.5 mm
XIENCE Sierra (3.5 x 18 mm)
150x magnification at max expansion
of 5.5 mm
Synergy
coating shows multiple cracks with delamination at its max
expansion of 4.25 mm from 3.5 mm
Xience Xpedition represents a powerful combination of deliverability, strong clinical data and broad availability of meaningful sizes, three factors that make this product well-suited to treat a wide range of patients, The impact of the changes to the stent delivery system is particularly notable in patients with complex coronary anatomy. For these patients, physicians have a new technology to reach the blockage and restore blood flow with ease and confidence. In order to cater the variegated demands of our beloved clients, we are offering a wide range of Abbott Xience Xpedition Stent