Turbidity meter LMTB200 with TSS measurements mode,selectable four turbidity units
Turbidity meter is equipped with a 4.5" TFT display
2 to 7 points calibration using the formazin standards
Selectable four turbidity units,including the NTU,FNU,EBC and ASBC
TSS conversion factor ensures accurate measurement for total suspended solids
Contiuous measurement mode that can used for indexing and matching the sample vials
Hold fuction freezes current reading for easy viewing and recording
Password protection prevents the unathorised calibration and settings
Help message as a operational guide that helps user quickly begin using the meter
System menu allows setting the 9 parameters,including the date and time,resolution etc..,
Reset feature automatically resumes all settings back to factory default settings
Portable Turbidity meter, has Principle Nephelometric Method (90)
2 to 5 points calibration, using formazin standards.
Selectable of 4 Turbidity units NTU, FNU, EBC, ASBC.
Single measurement mode, automatically identify and lock the measurement end.
Continuous measurement mode for indexing or matching vials.
Automatic Power OFF, effectively save battery energy consumption
Settings menu to customize the number of calibration points, date and time, display resolution etc...
Reset function, automatically restore the meter to factory default settings.
Expand memory to store or retrieve up to 100 sets of data.
USB communication interface, easy to transfer data or connect power adapter to the meter.
Automatic shutdown - After 15 minutes, If not in use
Carrying Case is Standard Supply
Principle-Â Nephelometric Method (90)
Turbidity Measuring range-0~1100 NTU/0~275 EBC/0~9999 ASBC
Display resolution -0.01 (0~99 NTU), 0.1 (100~999 NTU), 1 (1000~1100 NTU)
Measurement accuracy -2% (0~500 NTU),+3% (501~1100 NTU)
Calibration point -Â 2 to 5 points (0.02, 10, 200, 500, 1000NTU)
Calibration Standard value : 200, 500, 1000 NTU
4 turbidity units-Â NTU, FNU, EBC and ASBC.
Light source-Â Infrared light-emitting diode, 850nm
Detector : Silicon photoelectric
Stray light : ; 0.02 NTU
Vial size -Â 60 (height) 25 (diameter) mm
Sample Volume : (approx.) 30ml
Carrying Case- Available
Auto-Power OFF : Yes
Display -Â LCD
Data storage : 100 data readings
Ambient Temperature -Â 10 C~ 40 C
Interface- USB
Power supply type - AA battery 3 cells or DC5V power adapter
Packing Dimension -Â (LxWxH) 280 x 80 x250 mm
Net / Gross Weight : 300g / 1.5kg
Highly Stable & Accurate.
16 Character X 2 Lines Alphanumeric LCD.
30 mm flat bottom Test Tube.
0 to 1000 NTU
Automatic Range Selection.
Higher durability and long life.
Tested on quality parameters.
1000 Samples Storage with Date &Time.
Measurement of Temp. and Turbidity.
Technical Specifications:-
Model
S- 966
Turbidity
Range
0-1000 NTU
Resolution
1.0 NTU in lowest Range
Range Selection
Automatic
Accuracy
+3%, FS+1 -digit
Detector
Photodiode
Sample System
30mm Clear Glass Test Tube
Light Source
3.6 V/ 100ma LED
Calibration
Manual
Temperature
Range
0C to +100C
Resolution
0.1c
Accuracy
+0.2%
Input Type
Pt 100
Calibration
Auto/Manual
Display
16 Character X 2 Lines Alphanumeric LCD
Display Format
Temp &Turbidity Simultaneously
Setting
By Soft Touch Keys
Storage
1000 Samples With Date & Time
PC Interface
RS-232
Real Time Display
24 Hour Mode With Date
Power Supply